scholarly journals IMPROVEMENT OF GAS MONITORING METHODS IN WATER OF THE HYDROGEN-WATER COOLING SYSTEM OF NPP’S TURBINE GENERATOR

Author(s):  
Anatolii Tykhomyrov ◽  
Sergey Zaitsev ◽  
Vadim Chichеnin ◽  
Victor Kуshnevsky

The relevance of research is to ensure and improve the reliability of turbine generators (TG) with a hydrogen-water cooling system by monitoring the content of dissolved gases in the water of a hydrogen-water cooling system with monoethanolamine (MEA) – C2H7NO and water vapor in the cooling hydrogen of the turbine. In this work, the influence of ultrasonic vibrations on the decomposition of a mixture of water and turbine oil, organic acids (acetic acid - С2Н4О2, formic acid - СН2О2, oxalic acid - С2Н2О4) or monoethanolamine was determined. The distribution coefficients values were definedd for the following dissolved gases Н2, О2, N2, СО, СН4, С2Н2, С2Н4, С2Н6, С3Н6, С3Н8, which are of degradation products of water mix components when exposed to ultrasonic oscillation in the following system: «dissolved gas – mixture «water + monoethanolamine» – extractant argon (Ar)». The obtained values of the Кі distribution coefficients for dissolved gases in systems «dissolved gas – mixture «water + С2Н7NО» – extractant argon (Ar)» at a temperature of 293 K and a concentration of С2Н7NО at the level of 1 g/dm3 are close to similar values for dissolved gases in deionized water. The principle flow chart of multichannel gas chromatograph for detecting dissolved gases in water and steam of water in hydrogen was developed. Developed flow chart of 4-chennel gas chromatographer for defining dissolved gases in water includes the one gas chromatographer with conductivity detector, methanator, flame ionization detector, argon gas-bearing and supplementary gases of hydrogen and air.

2011 ◽  
Vol 383-390 ◽  
pp. 4715-4720
Author(s):  
Yan Zhang ◽  
Yan Hua Shen ◽  
Wen Ming Zhang

In order to ensure the reliable and safe operation of the electric driving motor of the articulated dump truck, water cooling system is installed for each motor. For the best performance of the water cooling system, not only the heat transfer should be enhanced to maintain the motor in relatively low temperature, but also the pressure drop in the water cooling system should be reduced to save energy by reducing the power consumption of the pump. In this paper, the numerical simulation of the cooling progress is completed and the temperature and pressure field distribution are obtained. The multi-objective optimization model is established which involves the cooling system structure, temperature field distribution and pressure field distribution. To improve the computational efficiency, the surrogate model of the simulation about the cooling process is established based on the Response Surface Methodology (RSM). After the multi-objective optimization, the Pareto optimal set is obtained. The proper design point, which could make the average temperature and pressure drop of the cooling system relative desirable, is chosen from the Pareto optimal set.


2021 ◽  
pp. 911-919
Author(s):  
Shashikant S. Jadhav ◽  
Avinash K. Parkhe ◽  
Subhash V. Jadhav ◽  
Samadhan J. Shinde

2008 ◽  
Vol 58 (5) ◽  
pp. 1142-1146 ◽  
Author(s):  
M. S. Kim ◽  
K. T. Q. Hoa ◽  
K. S. Baik ◽  
S. C. Park ◽  
C. N. Seong

2019 ◽  
Vol 142 (2) ◽  
Author(s):  
Wenjun Qiu ◽  
Zhengrong Ouyang

Abstract This paper presents an optimal control method for the prediction of parallel centrifugal variable frequency pump performance in any conditions to maximize the total efficiency of the pump system, thereby minimizing energy consumption. First, a theoretical model of parallel water pumping set was established, after which the shaft power model was setup specifically for the off-rating conditions. By combining the typical polynomial fitting method of the efficiency and the shaft power model we brought up, a new optimized control method was proposed. Using this method, the complex optimization task was solved with the optimal control of the operating number selection and speed ratios for parallel variable speed pumps based on the decision-making. The proposed method was subsequently applied to the pumping set of the water-cooling system in High Magnetic Field Facility. The practical testing results of the proposed method showed its superiority over both the primitive and the previous optimal methods, by considerably lowering the power consumption and accurately calculating the performance parameters in any conditions. The method has universality and simplicity for online implementation, which provides a reference for the control methods of parallel centrifugal pumps in variable flow systems with a differential pressure control strategy.


2015 ◽  
Vol 98-99 ◽  
pp. 1235-1238 ◽  
Author(s):  
B. Mendelevitch ◽  
J. Boscary ◽  
A. Peacock ◽  
M. Smirnow ◽  
R. Stadler

Sign in / Sign up

Export Citation Format

Share Document