scholarly journals PHYSICAL MEANING OF THE «REACTIVE POWER» CONCEPT APPLIED TO THREE-PHASE ENERGY SUPPLY SYSTEMS WITH NON-LINEAR LOAD

2015 ◽  
Vol 0 (6) ◽  
pp. 36-42 ◽  
Author(s):  
George G. Zhemerov ◽  
D. V. Tugay
Author(s):  
Satyanarayan Gorantla ◽  
Goli Ravi Kumar

The paper presents the analysis of harmonic distortion when non-linear load is connected in different phases of power system with STATCOM for singly excited induction generator system with wind turbine as prime mover. Now-a-days due to the drastically increased in use of non linear loads causes many power quality problems in power system network. Those problems are classified as reactive power problems, harmonics, voltage sags and swells. Out of these problems harmonic problems are major concern. Custom power devices proposed for mitigation of power quality in network. For compensation of harmonic, static compensator (STATCOM) is used. The paper presents the compensation of harmonic power quality issues using STATCOM for the system with singly-excited induction generator feeding non-linear load connected in different phases. STATCOM is controlled using synchronous reference frame theory to produce pulses to switches of STATCOM sensing the input parameters. Proposed concept was developed using MATLAB/SIMULINK software and results are presented for non-linear load connected in different phases of the power system. THD analysis was shown for source current and load current for different cases.


2018 ◽  
Vol 7 (2.8) ◽  
pp. 673
Author(s):  
Savitha Venkatesan ◽  
Booma Nagarajan

Due to unpredicted non-linear loads, power quality problems, a raise in the transmission system. One such problem is voltage sag. Voltage sag is caused by the non-linear load which demands reactive power, but the balanced 3F source provides required reactive power of the load with reduced voltage at the receiving end. In this paper, simulation study has been performed to reducethe voltage sag issue. A transmission system with generation source with different loading conditions is considered and study has been done. A 3F medium P model transmission line is designed with a power source of 11kV.  A shunt connected compensation unit called Static Synchronous Compensator (STATCOM) reduces the voltage sag in the transmission line. STATCOM provides the required reactive power demanded by the non-linear load along with the source for compensation of voltage sag. The STATCOM circuit comprises of Voltage source converter(VSC) unit and a DC source. Reactive power compensation is done by VSC unit firing angle control. The source of the STATCOM can also be from renewable energy system. This AC source is converted by a AC-DC-AC converter unit.The firing angle is controlled by the control unit which ensures the continuous and balanced power flow even under sudden change in load conditions. The simulation results depict the characteristics of the developed STATCOM.


Sign in / Sign up

Export Citation Format

Share Document