scholarly journals Central Air Conditioning Systems with Partial Indirect Evaporative Cooling and Utilization of Cold and Heat of Ventilation Emissions

Author(s):  
Mykhaylo Bozhenko ◽  
Tatiana Izhevska

A promising trend in air conditioning systems is the use of indirect evaporative cooling, but in the classic version it is effective in dry and hot climates. For the need to maintain comfortable air parameters in public buildings, it is not possible to fully implement such a process in the conditions of Ukraine (the relative humidity of the outside air ranges from 63 to 75 %). The aim of the work is to increase the energy efficiency of air conditioning systems with standard equipment through partial evaporative cooling and use for cooling water in cooling towers of the air removed from the rooms during the warm season, and in the cold season - use of the exhaust air for preheating the supply air in heat exchanger. A corresponding system diagram was developed and computational studies of a direct-flow circuit and a circuit with recirculation were carried out for one of the educational buildings of the Igor Sikorsky Kyiv Polytechnic Institute. According to the results of calculating the direct-flow circuit in the warm period, the energy efficiency of indirect evaporative cooling was 23.5 %. The annual amount of recovered heat of ventilation emissions for this scheme in the cold period was 3731 GJ / year, and the economic effect - 1473185 UAH / year. For a circuit with recirculation during a warm period, the greatest effect of indirect evaporative cooling is achieved with a recirculation rate of 10 %, and for the overall decrease in the cooling capacity of the air conditioner during this period the greatest impact is not indirect evaporative cooling, but recirculation. In the cold season, the greatest utilization effect is also achieved with a 10 % recirculation rate.

Energy ◽  
2019 ◽  
Vol 168 ◽  
pp. 505-515 ◽  
Author(s):  
Seung Jin Oh ◽  
Muhammad Wakil Shahzad ◽  
Muhammad Burhan ◽  
Wongee Chun ◽  
Chua Kian Jon ◽  
...  

2021 ◽  
Vol 2 (46) ◽  
pp. 16
Author(s):  
E. Dmytrochenkova

The article is devoted to the analysis of energy, economic and environmental efficiency, which are achieved by using indirect adiabatic cooling of air in the central air conditioner instead of direct cooling. Two corresponding schematic diagrams of air conditioning systems are considered. As a result of the calculations, it was found that indirect adiabatic cooling of the air makes it possible to reduce the consumption of cold and electricity by 65%. The monetary equivalent of reducing energy consumption can reach UAH 14,760 for 4 months of operation of the air conditioning system in cooling mode. Also, the use of this mode of operation of climatic equipment makes it possible to obtain a certain environmental effect in the form of reducing carbon dioxide emissions at the level of 5.15 tons per season.Keywords: indirect evaporative cooling, refrigeration capacity, irrigation chamber, economic efficiency, ecological effect


Author(s):  
V. Stepanenko ◽  
Y. Veremiichuk

The implementation of an integrated energy supply system is an effective way to increase energy efficiency, reduce CO2 emissions and increase the use of renewable energy, as well as provide opportunities for energy production, conversion and storage in interconnected infrastructures for energy system operators and consumers. Also, increasing the level of energy efficiency of the energy supply system is one of the important strategies to slow down the growth of demand and mitigate the negative impact on health, the economy and the environment. The article considers the integrated use of energy, the introduction of energy hubs as part of future energy networks and proposes a schematic diagram of an integrated energy supply system. The article presents the results of modeling and computational experiment of ventilation and air conditioning systems in the integrated power supply system, taking into account the technical and operational characteristics of SES, regulatory and technical documents and building codes. According to the results of the study, it is established that the schedule of SES generation and the schedule of electricity consumption by ventilation and air conditioning systems are similar, which leads to a reduction in operating costs and a reduction in the load on the building's power supply system. The scientific substantiation of the integration of the energy storage system into the energy supply structure has been further developed, which will ensure the reliability of the power supply and the efficiency of the solar power plant.


2019 ◽  
Vol 11 (4) ◽  
pp. 1036 ◽  
Author(s):  
Beom-Jun Kim ◽  
Junseok Park ◽  
Jae-Weon Jeong

The main objective of this study is to investigate the indoor air quality enhancement performance of two different liquid desiccant and evaporative cooling-assisted air conditioning systems, such as the variable air volume (VAV) system with the desiccant-enhanced evaporative (DEVap) cooler, and the liquid desiccant system with an indirect and direct evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS), compared with the conventional VAV system. The transient simulations of concentration variations of carbon dioxide (CO2), coarse particles, and fine particles (PM10 and PM2.5) in a model office space served by each system were performed using validated system models that were found in the literature. Based on the hourly thermal loads of the model space predicted by the TRNSYS 18 program, each air conditioning system was operated virtually using a commercial equation solver program (EES). The results indicated that the LD-IDECOAS provided the lowest annual indoor CO2 concentration among all the systems considered in this research, while the VAV system with DEVap cooler exceeded the threshold concentration (i.e., 1000 ppm) during the cooling season (i.e., July, August, and September). For the indoor particulate contaminant concentrations, both liquid desiccant and evaporative cooling-assisted air conditioning systems indicated lower indoor PM2.5 and PM10 concentrations compared with the reference system. The LD-IDECOAS and the VAV with a DEVap cooler demonstrated 33.3% and 23.5% lower annual accumulated indoor PM10 concentrations than the reference system, respectively. Similarly, the annual accumulated indoor PM2.5 concentration was reduced by 16% using the LD-IDECOAS and 17.1% using the VAV with DEVap cooler.


Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 522
Author(s):  
Su Liu ◽  
Jae-Weon Jeong

This study investigated the annual energy saving potential and system performance of two different evaporative cooling-based liquid desiccant and evaporative cooling-assisted air conditioning systems. One system used an indirect and direct evaporative cooler with a two-stage package to match the target supply air point. The other was equipped with a single-stage, packaged dew-point evaporative cooler that used a portion of the process air, which had been dehumidified in advance. Systems installed with the two evaporative coolers were compared to determine which one was more energy efficient and which one could provide better thermal comfort for building occupants in a given climate zone, using detailed simulation data. The detailed energy consumption data of these two systems were estimated using an engineering equation solver with each component model. The results showed that the liquid desiccant and dew-point evaporative-cooler-assisted 100% outdoor air system (LDEOAS) resulted in approximately 34% more annual primary energy consumption than that of the liquid desiccant and the indirect and direct evaporative-cooler-assisted 100% outdoor air system (LDIDECOAS). However, the LDEOAS could provide drier and cooler supply air, compared with the LDIDECOAS. In conclusion, LDIDECOAS has a higher energy saving potential than LDEOAS, with an acceptable level of thermal comfort.