scholarly journals Meta-analysis of serum and/or plasma D-dimer in the diagnosis of periprosthetic joint infection

2020 ◽  
Author(s):  
Cheng Li ◽  
Donara Margaryan ◽  
Cristina Ojeda-Thies ◽  
Carsten Perka ◽  
Andrej Trampuz

Abstract Background The purpose of this meta-analysis was to evaluate the diagnostic value of D-dimer in detecting periprosthetic joint infection (PJI). Methods A systematic search and screening of relevant studies was performed in the databases PubMed, Web of Science, and Embase using the following medical subject headings (MeSH) or keywords: “arthroplasty or joint prosthesis or joint replacement or periprosthetic joint or prosthetic joint”, “infection or infectious or infected”, and “D-dimer or serum D-dimer or plasma D-dimer or fibrin degradation products”. Data were subsequently analysed and processed using Meta-Disc. Results Seven studies with 1285 patients were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 0.75 (95% confidence interval [CI]: 0.70–0.79), 0.69 (95% CI: 0.66–0.72), 3.01 (95% CI: 1.84–4.93), 0.32 (95% CI: 0.19–0.53), and 10.20 (95% CI: 3.63–28.64), respectively. Subgroup analyses showed that the use of serum D-dimer had better sensitivity and specificity than plasma D-dimer for the diagnosis of PJI . Conclusion Serum D-dimer was shown to have a better diagnostic value than plasma D-dimer for the diagnosis of PJI. Further research is required for clarification.

2020 ◽  
Author(s):  
Cheng Li ◽  
Donara Margaryan ◽  
Cristina Ojeda-Thies ◽  
Carsten Perka ◽  
Andrej Trampuz

Abstract Background The purpose of this meta-analysis was to evaluate the diagnostic value of D-dimer in detecting periprosthetic joint infection (PJI). Methods A systematic search and screen of relevant studies was performed in the PubMed, Web of Science and Embase databases using the following medical subject headings (MeSH) or keywords: “arthroplasty or joint prosthesis or joint replacement or periprosthetic joint or prosthetic joint”, “infection or infectious or infected”, and “D-dimer or serum D-dimer or plasma D-dimer or fibrin degradation products”. Then, the data were analysed and processed by Meta-Disc software. Results A total of 7 studies with 1285 patients were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratio (DOR) were 0.75 (95% confidence interval [CI]: 0.70 to 0.79), 0.69 (95% CI: 0.66 to 0.72), 3.01 (95% CI: 1.84 to 4.93), 0.32 (95% CI: 0.19 to 0.53) and 10.20 (95% CI: 3.63 to 28.64), respectively. Subgroup analyses showed that use of serum D-dimer had better sensitivity and specificity than plasma D-dimer for the diagnosis of PJI (0.86, 0.84 vs. 0.67, 0.60, respectively). Conclusion Serum D-dimer had a better diagnostic value than plasma D-dimer for the diagnosis of PJI.


2018 ◽  
Vol 3 (5) ◽  
pp. 273-279 ◽  
Author(s):  
Cheng Li ◽  
Nora Renz ◽  
Cristina Ojeda Thies ◽  
Andrej Trampuz

Abstract. Introduction: Periprosthetic joint infection (PJI) is the most serious complication after arthroplasty, and the diagnosis of PJI is still challenging with modern medical technology. To improve the diagnostic rate, combined diagnostic methods are gradually beginning to be used to diagnose PJI. Sonication is one accurate way to diagnose PJI, but there is minimal research regarding the diagnostic value of sonicate fluid (SF) in blood culture bottles (BCB). Therefore, we evaluated this combined diagnostic method by meta-analysis.Methods: We searched English publications in electronic databases regarding the use of sonicate fluid in blood culture bottles (SF-BCB) for diagnosing PJI, screened the literature according to inclusion criteria, assessed the quality of the selected literature, and collected information regarding SF-BCB.Results: This meta-analysis includes 4 studies that evaluated SF-BCB for the diagnosis of PJI. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratio (DOR) are 0.85 (95% Confidence interval [CI], 0.77 to 0.91), 0.86 (CI, 0.81 to 0.91), 5.34 (CI, 3.13 to 9.11), 0.16 (CI, 0.06 to 0.48) and 39.01 (CI, 9.04 to 168.35), respectively. The area under the curve (AUC) of the summary receiver operating characteristic (SROC) is 0.9186 (standard error, 0.0205).Conclusion: SF-BCB has great value for the microbiological diagnosis of PJ, especially for patients with prior antibiotic treatment.


2020 ◽  
Author(s):  
Haitao Zhang ◽  
Xiaobo Sun ◽  
Pengfei Xin ◽  
Xingyang Zhu ◽  
Ke Jie ◽  
...  

Abstract Background: Periprosthetic joint infection (PJI) is one of the most devastating complications after total joint replacement. Up to now, the diagnosis of PJI is still in a dilemma. As a novel biomarker, whether D-Dimer is valuable in the diagnosis of PJI remains controversial. This meta-analysis attempts to determine the diagnostic accuracy of D-Dimer in PJI.Methods: Relevant literature was retrieved from PubMed, Embase, Web of Science, and Cochrane Library (from database establishment to April 2020). Literature quality was evaluated using Revman (Version 5.3). The random effect model was used in Stata version 14.0 software to combine sensitivity, specificity, likelihood ratio (LR), diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curve and area under SROC (AUC) to evaluate the diagnostic value of overall D-Dimer for PJI. Meta regression and subgroup analysis were performed according to the threshold, the study design, the sample size, the diagnostic gold standard, the country of study, and the type of sample.Results:A total of 9 studies were included in this study, including 1592 patients. The pooled sensitivity and specificity of D-Dimer for PJI diagnosis are 0.82(95%CI, 0.72~0.89) and 0.73(95%CI, 0.58~0.83), respectively. The pooled positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 2.99 (95%CI, 1.84~4.88) and 0.25 (95%CI, 0.15~0.41), respectively. The pooled AUC and diagnostic odds ratios were 0.85 (95%CI, 0.82~0.88) and 12.20 (95% CI, 4.98~29.86), respectively.Conclusion: D-Dimer is a promising biomarker for the diagnosis of PJI, which should be used in conjunction with other biomarkers or as an adjunct to other diagnostic methods to enhance diagnostic performance.


2022 ◽  
Vol 17 (1) ◽  
Author(s):  
Jisi Xing ◽  
Jiahao Li ◽  
Zijian Yan ◽  
Yijin Li ◽  
Xiaofang Liu ◽  
...  

Abstract Background Periprosthetic joint infection (PJI) is considered to be one of the most challenging complications of joint replacement, which remains unpredictable. As a simple and emerging biomarker, calprotectin (CLP) has been considered to be useful in ruling out PJI in recent years. The purpose of this study was to investigate the accuracy and sensitivity of CLP in the diagnosis of PJI. Methods We searched and screened the publications from PubMed, Web of Science, EMBASE, and Cochrane Library from database establishment to June 2021. Subsequently, Stata version 16.0 software was used to combine the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), operating characteristic curve, and area under the curve (AUC). Heterogeneity across articles was evaluated by the I2 statistics. Finally, sources of heterogeneity were detected by subgroup analysis based on study design, detection method, sample size, and cutoff values. Results A total of 7 studies were included in our study, comprising 525 patients. The pooled sensitivity, specificity, PLR, and NLR of CLP for PJI diagnosis were 0.94(95% CI 0.87–0.98), 0.93(95% CI 0.87–0.96), 13.65(95% CI 6.89–27.08), and 0.06(95% CI 0.02–0.15), respectively, while the DOR and AUC were 222.33(95% CI 52.52–941.11) and 0.98 (95% CI 0.96–0.99), respectively. Conclusion Synovial CLP is a reliable biomarker and can be used as a diagnostic criterion for PJI in the future. However, the uncertainty resulting from the poor study numbers and sample sizes limit our ability to definitely draw conclusions on the basis of our study.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Liping Pan ◽  
Hao Wu ◽  
Heng Liu ◽  
Xin Yang ◽  
Zhichao Meng ◽  
...  

Abstract Purpose D-dimer and fibrinogen, both belonging to coagulation parameters, are controversial for the diagnosis of periprosthetic joint infection (PJI). This meta-analysis was conducted to compare their diagnostic accuracies for PJI by synthesizing currently available evidence. Methods Cochrane Library, MEDLINE, Web of Science, and Embase up to March 1, 2020, and other relevant articles were searched. Five hundred and eighty-one articles were identified after initial research, and 11 studies were included finally. No threshold effects were found between studies. The pooled sensitivity, specificity, and positive and negative likelihood ratio were reported to evaluate the diagnostic performance with heterogeneity analysis. Z test statistics was used to analyze the difference of diagnostic performance between D-dimer and fibrinogen. Results The pooled sensitivity, specificity, and positive and negative likelihood ratio of D-dimer for PJI were 0.79 (95% [CI], 0.72–0.85), 0.77 (0.67–0.84), 3.38 (2.21–5.18), and 0.27 (0.18–0.41), respectively. As for fibrinogen, the pooled sensitivity, specificity, and positive and negative likelihood ratio for PJI were 0.75 (0.68–0.80), 0.85 (0.82–0.88), 5.12 (4.22–6.22), and 0.30 (0.23–0.37), respectively. Great heterogeneity was found in studies for D-dimer, and univariate meta-regression analysis revealed that number of involved joints, disease spectrum, comorbidities influencing D-dimer, and sample sources were the source of heterogeneity. Z test found that the pooled specificity of fibrinogen was significantly higher than D-dimer (0.85 ± 0.01 versus 0.77 ± 0.04, p = 0.03). The pooled positive likelihood ratio of fibrinogen was significantly higher than D-dimer (5.12 ± 0.51 versus 3.38 ± 0.74, p = 0.03). Conclusion Based on currently available evidence, the meta-analysis suggests that fibrinogen performs better than D-dimer as a rule-in diagnostic tool for its higher specificity. However, more prospective trials with larger size are still needed to provide further confirmation. Trial registration This meta-analysis was prospectively registered on PROSPERO (International prospective register of systematic reviews), and the registering number was CRD42020177176.


2022 ◽  
Vol 17 (1) ◽  
Author(s):  
Xinyu Peng ◽  
Haitao Zhang ◽  
Pengfei Xin ◽  
Guowen Bai ◽  
Yingjie Ge ◽  
...  

Abstract Background Periprosthetic joint infections (PJI) are a rare but severe complication of total joint arthroplasty (TJA). However, the diagnosis of PJI remains difficult. It is one of the research that focuses about diagnosis for PJI for majority researchers to discover a novel biomarker. This meta-analysis tried to evaluate diagnostic value of synovial calprotectin for PJI. Methods This meta-analysis search of the literature was conducted in PubMed, EMBASE, Web of Science, and the Cochrane Library. Literature quality was appraised using Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) based on RevMan (version 5.3). The diagnostic value of calprotectin for PJI was evaluated by calculating sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), diagnostic score and area under SROC (AUC) based on the Stata version 14.0 software. We conduct subgroup analysis according to the study design, cutoff values, the country of study, and gold standard. Results Seven studies were included in this meta-analysis. The pooled sensitivity of synovial calprotectin for the diagnosis of PJI was 0.94 (95% CI, 0.87–0.98), and the specificity was 0.93 (95% CI, 0.87–0.96). The pooled AUC, PLR, and NLR for synovial calprotectin were 0.98 (95% CI, 0.96–0.99), 13.65 (95% CI, 6.89–27.07), and 0.06 (95% CI, 0.02–0.15), respectively. The pooled diagnostic score and DOR were 5.4 (95% CI, 3.96–6.85) and 222.32 (95% CI, 52.52–941.12), respectively. Conclusion In summary, this meta-analysis indicates that synovial calprotectin is a promising biomarker of assistant diagnosis for PJI, as well as recommended test for excluding diagnostic tool.


2018 ◽  
Vol 3 (3) ◽  
pp. 156-164 ◽  
Author(s):  
Giovanni Riccio ◽  
Luca Cavagnaro ◽  
Wassim Akkouche ◽  
Giuliana Carrega ◽  
Lamberto Felli ◽  
...  

Abstract. Introduction: Biomarkers such as α-defensin demonstrated to be a potentially useful option in periprosthetic joint infection (PJI) diagnosis. Recently, a new point-of-care test for α-defensin level detection in synovial fluid has been commercialized in Europe. The aim of this study is to compare the α-defensin test (SynovasureTM) diagnostic ability with the main available clinical tests for periprosthetic joint infection diagnosis in a practical clinical setting of a Bone Infection Unit.Methods: Between 2015 and 2017, 146 patients with suspected chronic PJI were screened with SynovasureTM. Seventy-three of these met the Musculoskeletal Infection Society (MSIS) criteria and were included in the analysis. According to MSIS criteria, 40 patients (54.7%) were classified as infected and 33 (45.3%) as not infected. The results obtained with SynovasureTM were recorded and compared with standard diagnostic methods for PJI diagnosis.Results: SynovasureTM showed a sensitivity of 85.0 % (95% CI 70.2 to 94.3) and a specificity of 96.9 % (95% CI 83.8 to 99.9) for PJI detection. The positive likelihood ratio of SynovasureTM was 27.2 (95% CI 3.9 to 188.1) and the negative likelihood ratio was 0.2 (95% CI 0.1 to 0.3). The diagnostic odds ratio was 181.3 (95% CI 20.7 to 1590.4). SynovasureTM demonstrated a statistical significant difference when compared to Erythrocyte Sedimentation Rate (ESR) and C-reactive Protein (CRP) specificity (at least one positive test) and preoperative culture sensitivity (1 positive culture).Conclusion: Our findings show that SynovasureTM sensitivity is lower than quantitative α-D test, but when compared to the main available tests shows a good specificity and the highest DOR. On the SF it is the easier test to do, due to the fact that it needs a minimal amount of SF and it is not limited by blood contamination or antibiotic use. Whereas there is no single standalone test, SynovasureTM should be considered a reliable additional test for periprosthetic joint infection diagnosis in everyday clinical practice.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Jian Yao ◽  
Tao Bai ◽  
Bo Yang ◽  
Lizhong Sun

Abstract Objective This study aims to evaluate the diagnostic value of D-dimer for acute aortic dissection (AAD) by the method of meta-analysis. Methods PubMed, Cochrane Library, Web of Science, Embase, China National Knowledge Infrastructure (CNKI), and Wanfang databases from the establishment of the databases to December 2020 were systematically searched, and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) system was used to evaluate the quality of the literature. STATA 15.0 software was applied to calculate the pooled sensitivity, specificity, diagnostic odds ratio (DOR), positive likelihood ratio (+LR), negative likelihood ratio (−LR) to draw summary receiver operating characteristics (SROC) curve and calculate the area under the curve (AUC). Meta-regression and subgroup analyses were used to explore the source of heterogeneity. Results A total of 16 clinical studies were enrolled in this study, including 1135 patients. The results of the meta-analysis showed that the pooled sensitivity was 0.96 (95% CI 0.91–0.98), the pooled specificity was 0.70 (95% CI 0.57–0.81), and the pooled DOR was 56.57 (95% CI 25.11–127.44), the pooled +LR was 3.25 (95% CI 2.18–4.85), the pooled −LR was 0.06 (95% CI 0.03–0.12), and the AUC was 0.94 (95% CI 0.91–0.95). Meta-regression and subgroup analysis results showed that publication year, sample size and cutoff value might be sources of heterogeneity. When the concentration of D-dimer was less than or equal to 500 ng/ml, the sensitivity significantly increased. Conclusion D-dimer has an excellent diagnostic value for AAD. It is a useful tool for detecting suspected AAD because of the excellent pooled sensitivity. D-dimer ≤ 500 ng/ml increases the potential to identify the suspected patients with AAD.


2021 ◽  
Author(s):  
Jiangfeng Wu ◽  
Yue Sun ◽  
Yunlai Wang ◽  
Lijing Ge ◽  
Yun Jin ◽  
...  

Aims: In the present study, a meta-analysis was performed to evaluate the diagnostic value of endobronchial ultrasound (EBUS) elastography for differentiating benign and malignant hilar and mediastinal lymph nodes (LNs). Material and methods: A comprehensive literature search was carried out through PubMed, Embase, and Cochrane Library. Two authors screened the papers and extracted the data independently and any discrepancies were resolved by discussion. The methodolog-ical quality of each included study was assessed by the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the curve were calculated to evaluate the value of EBUS elastography for hilar and mediastinal LNs. Results: Seventeen studies with the number of 2307 LNs were included. There was significant heterogeneity across the included studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio for the diagnosis of hilar and mediastinal LNs by EBUS elastography were 0.90 (95% confidence interval [CI], 0.84-0.94), 0.78 (95% CI, 0.74-0.81), 4.1 (95% CI, 3.4-4.9), 0.12 (95% CI, 0.07-0.21) and 33 (95% CI, 17-64), respectively. Furthermore, area under the curve was calculated to be 0.86 (95% CI, 0.82-0.88). Conclusion: EBUS elastography is a valuable technology in the differentiation of benign and malignant hilar and mediastinal LNs and could provide supplementary diagnostic information during endobronchial ultrasound-guided transbronchial needle aspiration. The combination of EBUS elastography and B-mode EBUS could improve the diagnostic accuracy for hilar and mediastinal LNs.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Xingyang Zhu ◽  
Haitao Zhang ◽  
Xiaobo Sun ◽  
Yijin Li ◽  
Jiahao Li ◽  
...  

Abstract Background Fibrinogen (FIB) has recently been used as a biomarker to diagnose periprosthetic joint infection (PJI), but its reliability is still questionable. The aim of this study was to investigate the accuracy of FIB in the diagnosis of PJI after joint replacement. Methods We searched for literatures published in PubMed, EMBASE, and the Cochrane Library from the time of database inception to September 2020 and screened the studies according to the inclusion criteria. Then, we calculated the diagnostic parameters of FIB, including the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), area under the curve (AUC), and diagnostic odds ratio (DOR). In addition, we implemented subgroup analyses to identify the sources of heterogeneity. Results Seven studies including 1341 patients were selected in our meta-analysis. The pooled sensitivity, specificity, PLR, NLR, and DOR of FIB for PJI diagnosis were 0.78 (95% confidence interval [CI], 0.73–0.82), 0.83 (95% CI, 0.81–0.86), 4.60 (95% CI, 3.30–6.42), 0.24 (95% CI, 0.18–0.34), and 20.13 (95% CI, 14.80–27.36), respectively, while the AUC was 0.896. Conclusion The present study indicated that FIB was a reliable detection method and might be introduced into the diagnostic criteria for PJI. However, more robust studies are still needed to confirm the current findings, because most of the included studies were retrospective and had small sample sizes.


Sign in / Sign up

Export Citation Format

Share Document