Journal of Bone and Joint Infection
Latest Publications


TOTAL DOCUMENTS

235
(FIVE YEARS 145)

H-INDEX

14
(FIVE YEARS 5)

Published By Ivyspring International Publisher

2206-3552

2022 ◽  
Vol 7 (1) ◽  
pp. 1-9
Author(s):  
Karsten D. Ottink ◽  
Stefan J. Gelderman ◽  
Marjan Wouthuyzen-Bakker ◽  
Joris J. W. Ploegmakers ◽  
Andor W. J. M. Glaudemans ◽  
...  

Abstract. Background: A low-grade periprosthetic joint infection (PJI) may present without specific symptoms, and its diagnosis remains a challenge. Three-phase bone scintigraphy (TPBS) and white blood cell (WBC) scintigraphy are incorporated into recently introduced diagnostic criteria for PJI, but their exact value in diagnosing low-grade PJI in patients with nonspecific symptoms remains unclear. Methods: In this retrospective study, we evaluated patients with a prosthetic joint of the hip or knee who underwent TPBS and/or WBC scintigraphy between 2009 and 2016 because of nonspecific symptoms. We reviewed and calculated diagnostic accuracy of the TPBS and/or WBC scintigraphy to diagnose or exclude PJI. PJI was defined based on multiple cultures obtained during revision surgery. In patients who did not undergo revision surgery, PJI was ruled out by clinical follow-up of at least 2 years absent of clinical signs of infection based on MSIS 2011 criteria. Results: A total of 373 patients were evaluated, including 340 TPBSs and 142 WBC scintigraphies. Thirteen patients (3.5 %) were diagnosed with a PJI. TPBS sensitivity, specificity, and positive and negative predictive values (PPV, NPV) were 71 %, 65 %, 8 % and 98 %, respectively. Thirty-five percent of TPBS showed increased uptake. Stratification for time intervals between the index arthroplasty and the onset of symptoms did not alter its diagnostic accuracy. WBC scintigraphy sensitivity, specificity, PPV and NPV were 30 %, 90 %, 25 % and 94 %, respectively. Conclusion: Nuclear imaging does not have clear added value in patients with low a priori chance of periprosthetic joint infection.


2021 ◽  
Vol 6 (9) ◽  
pp. 457-466
Author(s):  
Germán Garabano ◽  
Hernán del Sel ◽  
Joaquin Anibal Rodriguez ◽  
Leonel Perez Alamino ◽  
Cesar Angel Pesciallo

Abstract. Background: The first objective of this retrospective study was to assess infection control rates in patients with chronic post-traumatic osteomyelitis (CPTO) of the femur or tibia treated with antibiotic cement-coated nails. The second objective was to compare the efficacy of custom-made nails versus commercially available antibiotic-coated nails in terms of infection control and need for reoperation. Methods: We reviewed a consecutive series of CPTO patients treated with antibiotic-coated nails who had a minimum follow-up of 24 months. We recorded the characteristics of the initial injury, the type of nail used, cement–nail debonding, infecting microorganisms, operating time, infection control, need for reoperation, and failure rate. We performed a comparative analysis between nails manufactured in the operating room (i.e., custom-made) and those commercially available. Results: Thirty patients were included. The affected bones were the femur (n=15) and the tibia (n=15). Twenty-one of the 30 initial injuries were open fractures. Staphylococcus aureus was the most frequently isolated microorganism (50 %). Sixteen patients were treated with custom-made nails and 14 with commercially available antibiotic-coated nails. At the time of extraction, four out of five custom-made antibiotic-coated nails experienced cement–bone debonding. Commercial nails were associated with shorter operating times (p<0.0001). The overall infection control rate was 96.66 %. Eight (26.66 %) patients needed reoperation. There was one failure (3.33 %) in the group treated with custom-made antibiotic-coated nails. We did not find significant differences between nail types in terms of reoperation, infection control, and failure rate. Conclusions: The use of antibiotic cement-coated nails proved useful in CPTO treatment. Commercially available nails had significantly shorter operating times and did not present cement–bone debonding during removal. Our results seem to indicate that both nail types are similar in terms of infection control and reoperation rates.


2021 ◽  
Vol 6 (9) ◽  
pp. 451-456
Author(s):  
Vendela M. Scheer ◽  
Malin Bergman Jungeström ◽  
Lena Serrander ◽  
Johan H. Scheer ◽  
Anders Kalén

Abstract. Introduction: Cutibacterium acnes is the most common cause of postoperative infections in orthopaedic shoulder surgery and is hard to eradicate with current measures. Newer strategies focus on reducing bacterial load on the skin before surgery. Several previous studies have used a large number of both described and undescribed sampling techniques. The purpose of this study was to compare three previously described swab techniques to obtain bacterial cultures: Levine's (L) technique, the Z technique and the pencil eraser swab (PES) technique. Methods: Three consecutive skin swabs were collected from the right shoulder, on 15 healthy male volunteers, using Levine's technique, Z technique and PES technique from each participant. To determine the number of living bacteria, serial dilutions were made, and after culturing for 5 d, viable count (VC) was expressed as CFU/mL (with CFU representing colony-forming unit). Results: The PES technique yielded significantly higher VC than the two others. PES: median 3700 CFU/mL, L: 200 CFU/mL and Z: 220 CFU/mL (p=0.003). There was no significant difference between the methods regarding the number of positive cultures. PES: 14/15, L: 11/15 and Z: 12/15. Conclusions: There is a need to harmonise sampling techniques of C. acnes in order to compare the efficacy of different measures to reduce the bacterial load on the skin before and during surgery. Of the three tested methods, the PES technique is simple and produces the highest bacterial counts.


2021 ◽  
Vol 6 (9) ◽  
pp. 443-450
Author(s):  
Jonathan Bourget-Murray ◽  
Rohit Bansal ◽  
Alexandra Soroceanu ◽  
Sophie Piroozfar ◽  
Pam Railton ◽  
...  

Abstract. The aim of this study was to determine the incidence, annual trend, and perioperative outcomes and identify risk factors of early-onset (≤90 d) deep surgical site infection (SSI) following primary total hip arthroplasty (THA) for osteoarthritis. We performed a retrospective study using prospectively collected patient-level data from January 2013 to March 2020. The diagnosis of deep SSI was based on the published Centre for Disease Control/National Healthcare Safety Network (CDC/NHSN) definition. The Mann–Kendall trend test was used to detect monotonic trends. Secondary outcomes were 90 d mortality and 90 d readmission. A total of 22 685 patients underwent primary THA for osteoarthritis. A total of 46 patients had a confirmed deep SSI within 90 d of surgery representing a cumulative incidence of 0.2 %. The annual infection rate decreased over the 7-year study period (p=0.026). Risk analysis was performed on 15 466 patients. Risk factors associated with early-onset deep SSI included a BMI > 30 kg m−2 (odds ratio (OR) 3.42 [95 % CI 1.75–7.20]; p<0.001), chronic renal disease (OR, 3.52 [95 % CI 1.17–8.59]; p=0.011), and cardiac illness (OR, 2.47 [1.30–4.69]; p=0.005), as classified by the Canadian Institute for Health Information. Early-onset deep SSI was not associated with 90 d mortality (p=0.167) but was associated with an increased chance of 90 d readmission (p<0.001). This study establishes a reliable baseline infection rate for early-onset deep SSI after THA for osteoarthritis through the use of a robust methodological process. Several risk factors for early-onset deep SSI are potentially modifiable, and therefore targeted preoperative interventions of patients with these risk factors is encouraged.


2021 ◽  
Vol 6 (9) ◽  
pp. 433-441
Author(s):  
Janet D. Conway ◽  
Vache Hambardzumyan ◽  
Nirav G. Patel ◽  
Shawn D. Giacobbe ◽  
Martin G. Gesheff

Abstract. Introduction: Cierny–Mader osteomyelitis classification is used to label A, B, or C hosts based on comorbidities. This study's purpose was to define the “true” host status of patients with orthopedic infection using serologic markers to quantify the competence of their immune system while actively infected. Methods: Retrospective chart review identified patients at a single-surgeon practice who were diagnosed with orthopedic infection between September 2013 and March 2020 and had immunological laboratory results. All patients were A or B hosts who underwent surgery to eradicate infection. Medical history, physical examination, and Cierny–Mader classification were recorded. Laboratory results included complement total, C3, C4, immunoglobulin G (IgG), immunoglobulin M (IgM), immunoglobulin A (IgA), immunoglobulin E (IgE), rheumatoid factor, and antineutrophil cytoplasmic antibodies (ANCA) panel. Clinically significant results were defined as flagged abnormal. Normal complement levels and normal IgG levels were considered abnormal when infection was present. Results: Of 105 patients, 99 (94 %) had documented lab abnormalities. Clinically significant abnormalities were found in 33 of 34 (97 %) type-A hosts and 66 of 71 (93 %) type-B hosts. Eleven of 105 (10.5 %) patients were formally diagnosed with primary immunodeficiency by a hematologist. IgG deficiency, of either low or normal value, in the face of infection comprised 91 % (30 of 34) type-A hosts and 86 % (56 of 71) type-B hosts. Six (5.7 %) patients received IgG replacement therapy. Twenty-eight patients had abnormal total complement levels (low or normal): 7.4 % (2 of 34) A hosts and 40 % (26 of 71) B hosts (p=0.002). B hosts had statistically significantly lower complement levels and significantly more no-growth cultures (p<0.03). Thirteen of 14 patients with recurrent infections had low or normal IgG levels. IgM was significantly lower between reinfected patients and those without reinfection (p=0.0005). Conclusions: Adding immunologic evaluation to the Cierny–Mader classification more accurately determines patients' true host status and better quantifies risk and outcome with respect to orthopedic infection. Immunologically deficient A hosts should be quantified as B hosts. IgG deficiencies may be addressed when deemed appropriate by the consulting hematologist/immunologist. Patients with recurrent infections had significantly lower IgM levels than their nonrecurrent infection counterparts.


2021 ◽  
Vol 6 (9) ◽  
pp. 425-432
Author(s):  
Robert Allan McCulloch ◽  
Amirul Adlan ◽  
Scott Evans ◽  
Michael Parry ◽  
Jonathan Stevenson ◽  
...  

Abstract. Introduction: The gastrocnemius myofascial flap is used to manage soft-tissue defects over the anterior aspect of the knee in the context of a patient presenting with a sinus and periprosthetic joint infection (PJI) or extensor mechanism failure. The aim of this study was twofold: firstly, to evaluate the outcomes of gastrocnemius flaps performed by appropriately trained orthopaedic surgeons in the context of PJI and, secondly, to evaluate the infection-free survival of this patient group. Patients and methods: We retrospectively reviewed 30 patients who underwent gastrocnemius flap reconstruction during staged revision total knee arthroplasty for prosthetic joint infection (PJI). All flaps were performed by an orthopaedic surgeon with orthoplastics training. Patients had a mean age of 68.9 years (range 50–84) and were followed up for a mean of 50.4 months (range 2–128 months). A total of 29 patients (97 %) were categorized into Musculoskeletal Infection Society (MSIS) local extremity grade 3 (greater than two compromising factors), and 52 % of PJIs were polymicrobial. The primary outcome measure was flap failure, and the secondary outcome measure was recurrent infection. Results: Flap survival was 100 % with no failures or early returns to theatre for flap problems such as necrosis or haematoma. Overall infection-free survival during the study period was 48 % (13 of 27 infected cases). Using limb salvage as the outcome, 77 % (23 of 30 patients) retained the limb. Infection recurrence occurred in 48 % (10 patients) in the type B3 cohort and 67 % (4 patients) in the type C3 cohort (p=0.65). Conclusions: The surgical technique for a gastrocnemius myofascial flap is reliable and reproducible when performed by appropriately trained orthopaedic surgeons, even in high-risk groups. However, the risks of recurrent infection and amputation remain high within our series due to poor host and extremity factors.


2021 ◽  
Vol 6 (9) ◽  
pp. 423-424
Author(s):  
Simon Martin Heinrich ◽  
Parham Sendi ◽  
Martin Clauss


2021 ◽  
Vol 6 (9) ◽  
pp. 413-421
Author(s):  
Tom A. G. Van Vugt ◽  
Jeffrey Heidotting ◽  
Jacobus J. Arts ◽  
Joris J. W. Ploegmakers ◽  
Paul C. Jutte ◽  
...  

Abstract. Introduction: Chronic osteomyelitis is a challenging condition in the orthopedic practice and traditionally treated using local and systemic antibiotics in a two-stage surgical procedure. With the introduction of the antimicrobial biomaterial S53P4 bioactive glass (Bonalive®), chronic osteomyelitis can be treated in a one-stage procedure. This study evaluated the mid-term clinical results of patients treated with S53P4 bioactive glass for long bone chronic osteomyelitis. Methods: In this prospective multi-center study, patients from two different university medical centers in the Netherlands were included. One-stage treatment consisted of debridement surgery, implantation of S53P4 bioactive glass, and treatment with culture-based systemic antibiotics. If required, wound closure by a plastic surgeon was performed. The primary outcome was the eradication of infection, and a secondary statistical analysis was performed on probable risk factors for treatment failure. Results: In total, 78 patients with chronic cavitary long bone osteomyelitis were included. Follow-up was at least 12 months (mean 46; standard deviation, SD, 20), and 69 patients were treated in a one-stage procedure. Overall infection eradication was 85 %, and 1-year infection-free survival was 89 %. Primary closure versus local/muscular flap coverage is the only risk factor for treatment failure. Conclusion: With 85 % eradication of infection, S53P4 bioactive glass is an effective biomaterial in the treatment of chronic osteomyelitis in a one-stage procedure. A major risk factor for treatment failure is the necessity for local/free muscle flap coverage. These results confirm earlier published data, and together with the fundamentally different antimicrobial pathways without antibiotic resistance, S53P4 bioactive glass is a recommendable biomaterial for chronic osteomyelitis treatment and might be beneficial over other biomaterials.


2021 ◽  
Vol 6 (9) ◽  
pp. 393-403
Author(s):  
Holly Duck ◽  
Suzanne Tanner ◽  
Debra Zillmer ◽  
Douglas Osmon ◽  
Kevin Perry

Abstract. Background: Total joint arthroplasties continue to increase as do periprosthetic joint infections (PJIs). Ultrasound-guided aspiration can yield useful synovial fluid for analysis while avoiding radiation exposure. This study presents a high-yield, ultrasound-guided technique with analysis of aspiration results. Methods: All consecutive ultrasound-guided aspirations of hip arthroplasties performed from May 2016 through to April 2019 were retrospectively reviewed. Patient demographic information, component specifics, presence of draining sinus, and inflammatory markers were recorded. Results of aspiration including volume, appearance, lavage use, synovial fluid differential leukocyte count, synovial neutrophil percent, and culture results were recorded. Surgical results, specimen cultures, and surgeon description of purulence were recorded. Aspiration results were compared to the surgical specimen results in all patients who underwent reoperations. Results: Review of 349 hip aspirations demonstrated accuracy of 87 %, sensitivity of 83 %, specificity of 89 %, positive predictive value of 79 %, and negative predictive value 91 %. Surgical and aspiration cultures matched in 81 % of cases. Bloody aspirates and aspirates obtained after lavage had less accuracy at 69 % and 60 %, respectively. Specificity was 100 % for cultures obtained with lavage and 91 % for bloody aspirates. Synovial leukocyte count and neutrophil percentage was obtained in 85 % of aspirations, and cultures were obtained in 98 % of aspirates. Contamination rate was 2 %. Conclusion: Ultrasound-guided aspirations aid in the diagnosis of PJI. The use of lavage to obtain fluid is helpful when aspiration cultures are positive. Bloody aspirates are less accurate but have high specificity. A low contamination rate and 88 % accuracy results with this meticulous technique.


2021 ◽  
Vol 6 (9) ◽  
pp. 405-412
Author(s):  
Edward J. McPherson ◽  
Matthew V. Dipane ◽  
Madhav Chowdhry ◽  
Andrew J. Wassef

Abstract. Chronic periprosthetic joint infection (PJI) is a devastating complication that requires an aggressive eradication protocol. Local antimicrobial delivery via dissolvable calcium sulfate (CaSO4) using small-sized beads (3–8 mm) has been utilized as an adjunctive treatment combined with implant exchange, radical debridement, and antimicrobial loaded acrylic spacers. The non-exothermic setting of CaSO4 theoretically allows for any antimicrobial agent to be used, so long as mixing methods provide a consistent fabrication within a reasonable set time. This study performed the first in vitro mixing study, in which various antimicrobial agents, used singularly and in combination, were mixed with a synthetic CaSO4 product to observe and document their interactions. The study was performed in a simulated operating room environment. We report a standard mix formula with set times, testing 22 different antimicrobial agents, combinations, and doses. For some antimicrobials and combinations, set times using the standard formula were either too fast or exceedingly slow. For these 14 antimicrobial agents and combinations, we were able to arrive at individualized mixing methods. We present all mixing formulas and set times. In all, we were able to establish mixing methods that incorporate all antimicrobial agents and combinations that we have seen utilized via surgeon-directed use.


Sign in / Sign up

Export Citation Format

Share Document