scholarly journals Diagnostic accuracy of calprotectin in periprosthetic joint infection: a diagnostic meta-analysis

2022 ◽  
Vol 17 (1) ◽  
Author(s):  
Jisi Xing ◽  
Jiahao Li ◽  
Zijian Yan ◽  
Yijin Li ◽  
Xiaofang Liu ◽  
...  

Abstract Background Periprosthetic joint infection (PJI) is considered to be one of the most challenging complications of joint replacement, which remains unpredictable. As a simple and emerging biomarker, calprotectin (CLP) has been considered to be useful in ruling out PJI in recent years. The purpose of this study was to investigate the accuracy and sensitivity of CLP in the diagnosis of PJI. Methods We searched and screened the publications from PubMed, Web of Science, EMBASE, and Cochrane Library from database establishment to June 2021. Subsequently, Stata version 16.0 software was used to combine the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), operating characteristic curve, and area under the curve (AUC). Heterogeneity across articles was evaluated by the I2 statistics. Finally, sources of heterogeneity were detected by subgroup analysis based on study design, detection method, sample size, and cutoff values. Results A total of 7 studies were included in our study, comprising 525 patients. The pooled sensitivity, specificity, PLR, and NLR of CLP for PJI diagnosis were 0.94(95% CI 0.87–0.98), 0.93(95% CI 0.87–0.96), 13.65(95% CI 6.89–27.08), and 0.06(95% CI 0.02–0.15), respectively, while the DOR and AUC were 222.33(95% CI 52.52–941.11) and 0.98 (95% CI 0.96–0.99), respectively. Conclusion Synovial CLP is a reliable biomarker and can be used as a diagnostic criterion for PJI in the future. However, the uncertainty resulting from the poor study numbers and sample sizes limit our ability to definitely draw conclusions on the basis of our study.

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Xingyang Zhu ◽  
Haitao Zhang ◽  
Xiaobo Sun ◽  
Yijin Li ◽  
Jiahao Li ◽  
...  

Abstract Background Fibrinogen (FIB) has recently been used as a biomarker to diagnose periprosthetic joint infection (PJI), but its reliability is still questionable. The aim of this study was to investigate the accuracy of FIB in the diagnosis of PJI after joint replacement. Methods We searched for literatures published in PubMed, EMBASE, and the Cochrane Library from the time of database inception to September 2020 and screened the studies according to the inclusion criteria. Then, we calculated the diagnostic parameters of FIB, including the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), area under the curve (AUC), and diagnostic odds ratio (DOR). In addition, we implemented subgroup analyses to identify the sources of heterogeneity. Results Seven studies including 1341 patients were selected in our meta-analysis. The pooled sensitivity, specificity, PLR, NLR, and DOR of FIB for PJI diagnosis were 0.78 (95% confidence interval [CI], 0.73–0.82), 0.83 (95% CI, 0.81–0.86), 4.60 (95% CI, 3.30–6.42), 0.24 (95% CI, 0.18–0.34), and 20.13 (95% CI, 14.80–27.36), respectively, while the AUC was 0.896. Conclusion The present study indicated that FIB was a reliable detection method and might be introduced into the diagnostic criteria for PJI. However, more robust studies are still needed to confirm the current findings, because most of the included studies were retrospective and had small sample sizes.


2020 ◽  
Vol 7 ◽  
Author(s):  
Ying Luo ◽  
Ying Xue ◽  
Liyan Mao ◽  
Qun Lin ◽  
Guoxing Tang ◽  
...  

Background: Tuberculous peritonitis (TP) is a common form of abdominal tuberculosis (TB). Diagnosing TP remains challenging in clinical practice. The aim of the present meta-analysis was to evaluate the diagnostic accuracy of peripheral blood (PB) T-SPOT and peritoneal fluid (PF) T-SPOT for diagnosing TP.Methods: PubMed, EmBase, Cochrane, Scopus, Google scholar, China national knowledge internet, and Wan-Fang databases were searched for relevant articles from August 1, 2005 to July 5, 2020. Statistical analysis was performed using Stata, Revman, and Meta-Disc software. Diagnostic parameters including pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were determined. Summary receiver operating characteristic curve was used to determine the area under the curve (AUC).Results: Twelve studies were eligible and included in the meta-analysis. The analysis showed that the pooled sensitivity and specificity of PB T-SPOT in diagnosing TP were 0.91 (95% CI, 0.88–0.94) and 0.78 (95% CI, 0.73–0.81), respectively, while the pooled PLR, NLR, and DOR were 4.05 (95% CI, 2.73–6.01), 0.13 (95% CI, 0.07–0.23), and 37.8 (95% CI, 15.04–94.98), respectively. On the other hand, the summary estimates of sensitivity, specificity, PLR, NLR, and DOR of PF T-SPOT for TP diagnosis were 0.90 (95% CI, 0.85–0.94), 0.78 (95% CI, 0.72–0.83), 6.35 (95% CI, 2.67–15.07), 0.14 (95% CI, 0.09–0.21), and 58.22 (95% CI, 28.76–117.83), respectively. Furthermore, the AUC of PB T-SPOT and PF T-SPOT for TP diagnosis were 0.91 and 0.94, respectively.Conclusions: Our results indicate that both PB T-SPOT and PF T-SPOT can be served as sensitive approaches for the diagnosis of TP. However, the unsatisfactory specificities of these two methods limit their application as rule-in tests for TP diagnosis. Furthermore, the standardization of the operating procedure of PF T-SPOT is further needed.


2018 ◽  
Vol 3 (5) ◽  
pp. 273-279 ◽  
Author(s):  
Cheng Li ◽  
Nora Renz ◽  
Cristina Ojeda Thies ◽  
Andrej Trampuz

Abstract. Introduction: Periprosthetic joint infection (PJI) is the most serious complication after arthroplasty, and the diagnosis of PJI is still challenging with modern medical technology. To improve the diagnostic rate, combined diagnostic methods are gradually beginning to be used to diagnose PJI. Sonication is one accurate way to diagnose PJI, but there is minimal research regarding the diagnostic value of sonicate fluid (SF) in blood culture bottles (BCB). Therefore, we evaluated this combined diagnostic method by meta-analysis.Methods: We searched English publications in electronic databases regarding the use of sonicate fluid in blood culture bottles (SF-BCB) for diagnosing PJI, screened the literature according to inclusion criteria, assessed the quality of the selected literature, and collected information regarding SF-BCB.Results: This meta-analysis includes 4 studies that evaluated SF-BCB for the diagnosis of PJI. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratio (DOR) are 0.85 (95% Confidence interval [CI], 0.77 to 0.91), 0.86 (CI, 0.81 to 0.91), 5.34 (CI, 3.13 to 9.11), 0.16 (CI, 0.06 to 0.48) and 39.01 (CI, 9.04 to 168.35), respectively. The area under the curve (AUC) of the summary receiver operating characteristic (SROC) is 0.9186 (standard error, 0.0205).Conclusion: SF-BCB has great value for the microbiological diagnosis of PJ, especially for patients with prior antibiotic treatment.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Liping Pan ◽  
Hao Wu ◽  
Heng Liu ◽  
Xin Yang ◽  
Zhichao Meng ◽  
...  

Abstract Purpose D-dimer and fibrinogen, both belonging to coagulation parameters, are controversial for the diagnosis of periprosthetic joint infection (PJI). This meta-analysis was conducted to compare their diagnostic accuracies for PJI by synthesizing currently available evidence. Methods Cochrane Library, MEDLINE, Web of Science, and Embase up to March 1, 2020, and other relevant articles were searched. Five hundred and eighty-one articles were identified after initial research, and 11 studies were included finally. No threshold effects were found between studies. The pooled sensitivity, specificity, and positive and negative likelihood ratio were reported to evaluate the diagnostic performance with heterogeneity analysis. Z test statistics was used to analyze the difference of diagnostic performance between D-dimer and fibrinogen. Results The pooled sensitivity, specificity, and positive and negative likelihood ratio of D-dimer for PJI were 0.79 (95% [CI], 0.72–0.85), 0.77 (0.67–0.84), 3.38 (2.21–5.18), and 0.27 (0.18–0.41), respectively. As for fibrinogen, the pooled sensitivity, specificity, and positive and negative likelihood ratio for PJI were 0.75 (0.68–0.80), 0.85 (0.82–0.88), 5.12 (4.22–6.22), and 0.30 (0.23–0.37), respectively. Great heterogeneity was found in studies for D-dimer, and univariate meta-regression analysis revealed that number of involved joints, disease spectrum, comorbidities influencing D-dimer, and sample sources were the source of heterogeneity. Z test found that the pooled specificity of fibrinogen was significantly higher than D-dimer (0.85 ± 0.01 versus 0.77 ± 0.04, p = 0.03). The pooled positive likelihood ratio of fibrinogen was significantly higher than D-dimer (5.12 ± 0.51 versus 3.38 ± 0.74, p = 0.03). Conclusion Based on currently available evidence, the meta-analysis suggests that fibrinogen performs better than D-dimer as a rule-in diagnostic tool for its higher specificity. However, more prospective trials with larger size are still needed to provide further confirmation. Trial registration This meta-analysis was prospectively registered on PROSPERO (International prospective register of systematic reviews), and the registering number was CRD42020177176.


2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


2019 ◽  
Vol 2019 ◽  
pp. 1-13 ◽  
Author(s):  
Qingqin Hao ◽  
Yadi Han ◽  
Wei Xia ◽  
Qinghui Wang ◽  
Huizhong Qian

Emerging studies have reported circRNAs were dysregulated in HCC. However, the clinical value of these circRNAs remains to be clarified. Herein, we aimed to comprehensively explore their association with the diagnosis, prognosis, and clinicopathological characteristics of HCC. PubMed, EMBASE, Web of Science, and Cochrane Library databases were comprehensively searched for eligible studies up to October 30, 2018. The diagnostic effect was evaluated by the pooled sensitivity, specificity, and other indexes. The pooled hazard ratio (HR) for overall survival (OS) and recurrence free survival (RFS) was calculated to assess the prognostic value. Ten studies on diagnosis, 12 on prognosis, and 23 on clinicopathology were identified from the databases. A total of 11 upregulated and 11 downregulated circRNAs showed an association with clinicopathological features of HCC. For the diagnosis analyses, the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) of circRNAs for HCC were 0.74 (95%CI: 0.65-0.82) and 0.76 (95%CI: 0.70-0.81), 3.1 (95%CI: 2.5-3.8), 0.34 (95%CI: 0.25-0.47), and 9 (95%CI: 6-14), respectively. The area under SROC curve (AUC) was 0.81 (95% CI: 0.78–0.84), indicating moderate diagnostic accuracy. In stratified analyses, the diagnostic performance of circRNAs varied based on the source of control and specimen type. For the prognosis analyses, increased expression of upregulated circRNAs was associated with worse OS (HR: 3.67, 95%: 2.07-6.48), while high expression of downregulated circRNAs was associated with better OS (HR: 0.38, 95%: 0.30-0.48). In conclusion, this study reveals that circRNAs may serve as promising diagnostic and prognostic biomarkers for HCC. However, further investigations are still required to explore the clinical value of circRNAs.


Cancers ◽  
2021 ◽  
Vol 13 (21) ◽  
pp. 5253
Author(s):  
Md. Mohaimenul Islam ◽  
Tahmina Nasrin Poly ◽  
Bruno Andreas Walther ◽  
Ming-Chin Lin ◽  
Yu-Chuan (Jack) Li

Gastric cancer (GC) is one of the most newly diagnosed cancers and the fifth leading cause of death globally. Identification of early gastric cancer (EGC) can ensure quick treatment and reduce significant mortality. Therefore, we aimed to conduct a systematic review with a meta-analysis of current literature to evaluate the performance of the CNN model in detecting EGC. We conducted a systematic search in the online databases (e.g., PubMed, Embase, and Web of Science) for all relevant original studies on the subject of CNN in EGC published between January 1, 2010, and March 26, 2021. The Quality Assessment of Diagnostic Accuracy Studies-2 was used to assess the risk of bias. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Moreover, a summary receiver operating characteristic curve (SROC) was plotted. Of the 171 studies retrieved, 15 studies met inclusion criteria. The application of the CNN model in the diagnosis of EGC achieved a SROC of 0.95, with corresponding sensitivity of 0.89 (0.88–0.89), and specificity of 0.89 (0.89–0.90). Pooled sensitivity and specificity for experts endoscopists were 0.77 (0.76–0.78), and 0.92 (0.91–0.93), respectively. However, the overall SROC for the CNN model and expert endoscopists was 0.95 and 0.90. The findings of this comprehensive study show that CNN model exhibited comparable performance to endoscopists in the diagnosis of EGC using digital endoscopy images. Given its scalability, the CNN model could enhance the performance of endoscopists to correctly stratify EGC patients and reduce work load.


2021 ◽  
Author(s):  
Jiangfeng Wu ◽  
Yue Sun ◽  
Yunlai Wang ◽  
Lijing Ge ◽  
Yun Jin ◽  
...  

Aims: In the present study, a meta-analysis was performed to evaluate the diagnostic value of endobronchial ultrasound (EBUS) elastography for differentiating benign and malignant hilar and mediastinal lymph nodes (LNs). Material and methods: A comprehensive literature search was carried out through PubMed, Embase, and Cochrane Library. Two authors screened the papers and extracted the data independently and any discrepancies were resolved by discussion. The methodolog-ical quality of each included study was assessed by the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the curve were calculated to evaluate the value of EBUS elastography for hilar and mediastinal LNs. Results: Seventeen studies with the number of 2307 LNs were included. There was significant heterogeneity across the included studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio for the diagnosis of hilar and mediastinal LNs by EBUS elastography were 0.90 (95% confidence interval [CI], 0.84-0.94), 0.78 (95% CI, 0.74-0.81), 4.1 (95% CI, 3.4-4.9), 0.12 (95% CI, 0.07-0.21) and 33 (95% CI, 17-64), respectively. Furthermore, area under the curve was calculated to be 0.86 (95% CI, 0.82-0.88). Conclusion: EBUS elastography is a valuable technology in the differentiation of benign and malignant hilar and mediastinal LNs and could provide supplementary diagnostic information during endobronchial ultrasound-guided transbronchial needle aspiration. The combination of EBUS elastography and B-mode EBUS could improve the diagnostic accuracy for hilar and mediastinal LNs.


2020 ◽  
Author(s):  
Cheng Li ◽  
Donara Margaryan ◽  
Cristina Ojeda-Thies ◽  
Carsten Perka ◽  
Andrej Trampuz

Abstract Background The purpose of this meta-analysis was to evaluate the diagnostic value of D-dimer in detecting periprosthetic joint infection (PJI). Methods A systematic search and screen of relevant studies was performed in the PubMed, Web of Science and Embase databases using the following medical subject headings (MeSH) or keywords: “arthroplasty or joint prosthesis or joint replacement or periprosthetic joint or prosthetic joint”, “infection or infectious or infected”, and “D-dimer or serum D-dimer or plasma D-dimer or fibrin degradation products”. Then, the data were analysed and processed by Meta-Disc software. Results A total of 7 studies with 1285 patients were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratio (DOR) were 0.75 (95% confidence interval [CI]: 0.70 to 0.79), 0.69 (95% CI: 0.66 to 0.72), 3.01 (95% CI: 1.84 to 4.93), 0.32 (95% CI: 0.19 to 0.53) and 10.20 (95% CI: 3.63 to 28.64), respectively. Subgroup analyses showed that use of serum D-dimer had better sensitivity and specificity than plasma D-dimer for the diagnosis of PJI (0.86, 0.84 vs. 0.67, 0.60, respectively). Conclusion Serum D-dimer had a better diagnostic value than plasma D-dimer for the diagnosis of PJI.


2020 ◽  
Author(s):  
Cheng Li ◽  
Donara Margaryan ◽  
Cristina Ojeda-Thies ◽  
Carsten Perka ◽  
Andrej Trampuz

Abstract Background The purpose of this meta-analysis was to evaluate the diagnostic value of D-dimer in detecting periprosthetic joint infection (PJI). Methods A systematic search and screening of relevant studies was performed in the databases PubMed, Web of Science, and Embase using the following medical subject headings (MeSH) or keywords: “arthroplasty or joint prosthesis or joint replacement or periprosthetic joint or prosthetic joint”, “infection or infectious or infected”, and “D-dimer or serum D-dimer or plasma D-dimer or fibrin degradation products”. Data were subsequently analysed and processed using Meta-Disc. Results Seven studies with 1285 patients were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 0.75 (95% confidence interval [CI]: 0.70–0.79), 0.69 (95% CI: 0.66–0.72), 3.01 (95% CI: 1.84–4.93), 0.32 (95% CI: 0.19–0.53), and 10.20 (95% CI: 3.63–28.64), respectively. Subgroup analyses showed that the use of serum D-dimer had better sensitivity and specificity than plasma D-dimer for the diagnosis of PJI . Conclusion Serum D-dimer was shown to have a better diagnostic value than plasma D-dimer for the diagnosis of PJI. Further research is required for clarification.


Sign in / Sign up

Export Citation Format

Share Document