scholarly journals Visual outcomes of Visian ICL implantation for high myopia in patients with shallow anterior chamber depth

2019 ◽  
Author(s):  
Lingling Niu ◽  
Huamao Miao ◽  
Tian Han ◽  
Lan Ding ◽  
Xiaoying Wang ◽  
...  

Abstract Background: High myopia with shallow anterior chamber depth (ACD less than 2.8 mm) is not rare. This observational study aims to evaluate visual outcomes after implantation of the Visian Implantable Collamer Lens with a central hole (ICL V4c) in these patients. Methods: A prospective cohort of consecutive 51 eyes of 31 patients (20 to 42 years old) was followed for at least 12 months (average 15.35 ± 4.90 months, rangers from 12 to 25 months). The preoperative ACD was 2.74 ± 0.04 mm (2.65 to 2.79 mm). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), intraocular pressure (IOP), manifest refraction, vault, and endothelial cell density (ECD) were measured during the follow-ups after surgery. Results: All surgeries were performed safely and no complication was observed during the follow-up. At the last follow-up, the safety index (postoperative CDVA / preoperative CDVA) was 1.33 ± 0.60 and the efficacy index (postoperative UDVA / preoperative CDVA) was 1.14 ± 0.54. After the surgery, no eye had decreased CDVA and 59% (30 eyes) of the eyes gained at least one line. Forty-seven eyes (92%) were within ± 1.0 D and 35 eyes (69%) were within ± 0.5 D of the attempted refraction. The mean postoperative vault was 380.00 ± 152.84 µm (90 to 700µm). The ECD was reduced by 8.38 ± 0.06% as compared to the preoperative value (p < 0.001). No significant change was observed in IOP (p = 0.061) at the last follow-up. Ultrasound Biomicroscopy (UBM) showed none of the eyes had trabecular-iris angle closed. Conclusions: In this prospective observational study, ICL V4c implantation in patients with high myopia and shallow ACD achieved satisfying and stable visual outcomes. Its long-term safety and stability require further investigation. Trial Registration: This trial was retrospectively registered on 05/08/2018 under the number (ChiCTR1800017594)

2019 ◽  
Author(s):  
Lingling Niu ◽  
Huamao Miao ◽  
Tian Han ◽  
Lan Ding ◽  
Xiaoying Wang ◽  
...  

Abstract Background: High myopia with shallow anterior chamber depth (ACD less than 2.8 mm) is not rare. This observational study aims to evaluate visual outcomes after implantation of the Visian Implantable Collamer Lens with a central hole (ICL V4c) in these patients. Methods: A prospective cohort of consecutive 51 eyes of 31 patients (20 to 42 years old) was followed for at least 12 months (average 15.35 ± 4.90 months, rangers from 12 to 25 months). The preoperative ACD was 2.74 ± 0.04 mm (2.65 to 2.79 mm). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), intraocular pressure (IOP), manifest refraction, vault, and endothelial cell density (ECD) were measured during the follow-ups after surgery. Results: All surgeries were performed safely and no complication was observed during the follow-up. At the last follow-up, the safety index (postoperative CDVA / preoperative CDVA) was 1.33 ± 0.60 and the efficacy index (postoperative UDVA / preoperative CDVA) was 1.14 ± 0.54. After the surgery, no eye had decreased CDVA and 59% (30 eyes) of the eyes gained at least one line. Forty-seven eyes (92%) were within ± 1.0 D and 35 eyes (69%) were within ± 0.5 D of the attempted refraction. The mean postoperative vault was 380.00 ± 152.84 µm (90 to 700µm). The ECD was reduced by 8.38 ± 0.06% as compared to the preoperative value (p < 0.001). No significant change was observed in IOP (p = 0.061) at the last follow-up. Ultrasound Biomicroscopy (UBM) showed none of the eyes had trabecular-iris angle closed. Conclusions: In this prospective observational study, ICL V4c implantation in patients with high myopia and shallow ACD achieved satisfying and stable visual outcomes. Its long-term safety and stability require further investigation. Trial Registration: This trial was retrospectively registered on 05/08/2018 under the number (ChiCTR1800017594)


2019 ◽  
Author(s):  
Lingling Niu ◽  
Huamao Miao ◽  
Tian Han ◽  
Lan Ding ◽  
Xiaoying Wang ◽  
...  

Abstract Background: High myopia with shallow anterior chamber depth (ACD < 2.8 mm) is not rare. This observational study aims to: evaluate clinical outcomes after implantation of the Visian Implantable Collamer Lens with a central hole (ICL V4c) in these patients. Methods: A prospective cohort of consecutive 51 eyes of 31 patients (20 to 42 years old) was followed for 15.35 ± 4.90 months (12 to 25 months). The preoperative ACD was 2.74 ± 0.04 mm (2.65 to 2.79 mm). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), intraocular pressure (IOP), manifest refraction, vault, and endothelial cell density (ECD) were measured during the follow-ups after the surgery. Results: All surgeries were performed safely and no complication was observed during the follow-ups. At the last follow-up, the safety index (postoperative CDVA / preoperative CDVA) was 1.33 ± 0.60 and the efficacy index (postoperative UDVA / preoperative CDVA) was 1.14 ± 0.54. After the surgery, no eye had decreased CDVA and 59% (30 eyes) of the eyes gained at least one line. Forty-seven eyes (92%) were within ± 1.0 D and 35 eyes (69%) were within ± 0.5 D of the attempted refraction. The mean postoperative vault was 380.00 ± 152.84 µm (90 to 700µm). The ECD was reduced by 8.38 ± 0.06% compared to the preoperative value (p < 0.001). No significant change was observed in IOP (p = 0.061) at the last follow-up. Ultrasound Biomicroscopy (UBM) showed none of the eyes had trabecular-iris angle closed. Conclusions: In this prospective observational study, ICL V4c implantation in patients with high myopia and shallow ACD achieved satisfying and stable visual outcomes. Its long-term safety and stability require further investigation. Trial Registration: This trial was retrospectively registered on 05/08/2018 under the number (ChiCTR1800017594)


2021 ◽  
pp. bjophthalmol-2021-319205
Author(s):  
Yuhao Ye ◽  
Jing Zhao ◽  
Lingling Niu ◽  
Wanru Shi ◽  
Xiaoying Wang ◽  
...  

PurposeTo investigate the long-term safety and efficacy of implantable collamer lens (ICL) V4c implantation and changes in the anterior lens density (ALD) in patients with myopia ≥40 years of age.MethodsThis prospective study included 104 eyes of 52 patients >40 years of age before ICL V4c implantation. Spherical equivalent (SE), uncorrected distance visual acuity, corrected distance visual acuity (CDVA), intraocular pressure, endothelial cell density, anterior chamber depth, anterior chamber volume and anterior chamber angle preoperatively, at 1 and 3 months, and at 3 years postoperatively were recorded. Pentacam HR was used to analyse ALD changes at a depth of 0.5, 1.0 and 1.5 mm within a 3 mm diameter range around the pupil’s centre.ResultsThe overall follow-up was uneventful at 42±7.1 months; the safety index at last follow-up was 1.26±0.35 and the efficacy index was 0.91±0.41. No eye lost the Snellen line of CDVA, 76% of the eyes had an increase in CDVA for ≥1 line and 62% had an SE within ±0.50 dioptre. The increase in ALD at 0.5, 1 and 1.5 mm was 16.52%±10.46%, 16.72%±9.85% and 17.28%±11.93%, respectively. Preoperative, 1-month and 3-month postoperative ALDs showed correlations with SE and age, and ALD at last follow-up was correlated only with age. There was no correlation between ALD and any other parameters.ConclusionICL V4c shows long-term safety and efficacy in people ≥40 years of age. ALD increased in such patients, which may be related to age and SE.


2020 ◽  
pp. bjophthalmol-2020-316144
Author(s):  
Wen Yang ◽  
Jing Zhao ◽  
Ling Sun ◽  
Jiao Zhao ◽  
Lingling Niu ◽  
...  

BackgroundTo evaluate the changes in corneal endothelium cell density (ECD) and the correlated factors after Implantable Collamer Lens (ICL) V4c implantation.MethodsIn this retrospective, consecutive study, 48 eyes of 25 patients with myopia who underwent ICL V4c implantation were enrolled. Patients were followed up for at least 4 years, during which manifest refraction, uncorrected distance visual acuity, corrected distance visual acuity (CDVA), intraocular pressure, ECD, anterior chamber depth, anterior chamber volume (ACV), anterior chamber angle (ACA), vault and distance from the corneal endothelium to the central ICL (C-ICL) were measured. Spearman’s correlation analysis was used to identify variables correlated with changes in ECD, and generalised estimating equation model adjusting within-patient intereye correlations was used to predict changes in ECD.ResultsAll surgeries were performed safely with no complications during follow-up (average 52±2.9 months). Safety and efficacy indices were 1.23±0.22 and 1.04±0.16, respectively. No eyes had decreased CDVA, and 67% gained one or more lines. Further, 79% were within ±0.50 D, and 100% were within ±1.0 D of the attempted refraction. Additionally, a 4.03%±2.2% reduction in ECD compared with the preoperative value was observed at the last follow-up visit. Changes in ECD were significantly correlated with vault, C-ICL, change in ACA and change in ACV. Vault was the most significant factor for changes in ECD.ConclusionsICL V4c implantation is safe and effective for myopia correction. Anterior segment biometric parameters including the vault, ACA and C-ICL may influence changes in ECD; specifically, the vault plays a major role.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Lingling Niu ◽  
Huamao Miao ◽  
Tian Han ◽  
Lan Ding ◽  
Xiaoying Wang ◽  
...  

2019 ◽  
Vol 30 (3) ◽  
pp. 462-468 ◽  
Author(s):  
Yi Zhu ◽  
Jing Zhang ◽  
Haobin Zhu ◽  
Jili Chen ◽  
Jibo Zhou

Purpose:To evaluate the vault change and anterior segment movement induced by mydriasis in moderate-to-high myopic eyes with implantable collamer lenses (ICL).Setting:Shanghai, ChinaDesign:A prospective consecutive observational study.Methods:A total of 45 eyes of 24 patients with ICL V4 implantation and 128 eyes of 65 patients with ICL V4c implantation were included and analyzed. Anterior chamber depth, posterior corneal endothelium-to-ICL distance, and vault before and after mydriasis were measured by Pentacam (Oculus, Wetzlar, Germany) at 1, 3, and 6 months after surgery.Results:Significant vault increases and anterior chamber depth increases induced by mydriasis were noted in both ICL V4 and V4c groups at 1, 3, and 6 months postoperatively. The corneal endothelium-ICL distance increased significantly in eyes with implanted ICL V4c after mydriasis at 3 and 6 months. Moreover, mydriasis-induced vault increases were greater in the ICL V4 group than in the ICL V4c group at 3 and 6 months. In eyes with implanted ICL V4c, mydriasis-induced vault increases were significantly greater at 1 month than at 3 and 6 months.Conclusion:Mydriasis results in a general vault increase in eyes with implanted ICLs. The adjustment of the pressure equilibrium via the central hole of the ICL V4c has an important role in vault change. The mydriasis-induced vault increases tend toward stability after 3 months postoperatively. Mydriasis is relatively safe in eyes with ICL implantation.


2018 ◽  
Vol 12 (1) ◽  
pp. 256-263 ◽  
Author(s):  
Mohammad M. Shehadeh ◽  
Mohammad T. Akkawi ◽  
Ammar A. Aghbar ◽  
Muna T. Musmar ◽  
Malak N Khabbas ◽  
...  

Background: Laser corneal refractive surgery suits, technology and nomograms are improving with time. This may improve the refractive and visual outcomes of the patients. Objectives: To evaluate the safety, efficacy, stability, and predictability of wavefront-optimized photorefractive keratectomy and Laser-assisted in-situ keratomileusis in patients with myopia and myopic astigmatism over 1-year using WaveLight® EX500 Excimer Laser machine. Methods: In this prospective cohort study, refractive and visual outcomes in 596 eyes (365 patients), either having myopia or myopic astigmatism were assessed. Patients were divided into Two groups: 1) Patients who underwent PRK (53 eyes have myopia and 217 eyes have myopic astigmatism), 2) Patients who underwent LASIK (53 eyes have myopia and 273 eyes have myopic astigmatism). Results: At 12 months postoperatively 94.3% of the myopic patients reached their preoperative best corrected distance visual acuity at the final one year follow up visit post PRK and LASIK. In patients with myopic astigmatism who underwent LASIK and PRK, 95.2%, and 96.3% of the patients reached their preoperative best corrected distance visual acuity at the final one year follow up visit post LASIK and PRK, respectively. The efficacy and safety indices were 1.00 or more for all groups with no eye lost any line of best corrected distance visual acuity. Conclusion: Our study results confirm the excellent efficacy, safety, good predictability and stability of myopia / myopic astigmatism correction by either wavefront- optimized LASIK or PRK over 1-year follow-up without significant differences between them using the WaveLight® EX500 excimer laser system.


2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Alper Ağca ◽  
İhsan Çakır ◽  
Beril Tülü Aygün ◽  
Dilek Yaşa ◽  
Yusuf Yıldırım ◽  
...  

Purpose. To report long-term visual and refractive results of small-incision lenticule extraction (SMILE) in treatment of high myopia. Materials and Methods. Medical records of patients who underwent SMILE for surgical correction of myopia or myopic astigmatism were retrospectively reviewed. Only patients with a preoperative spherical equivalent of subjective manifest refraction (SE) ≥ 6 D and a postoperative follow-up of 5 years were included in the study. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and SE were analyzed preoperatively and at 1-, 3-, and 5-year postoperative periods. Results. Thirty-seven eyes of 37 patients were included in the study. The mean attempted SE was −7.47 ± 1.10 D (range −6.00 to −10.00 D). At the 5-year visit, the mean difference between achieved and attempted SE was −0.43 ± 0.47 (0.50 to −1.25 D). Mean postoperative UDVA and CDVA were 0.20 ± 0.18 and 0.06 ± 0.08 logMAR, respectively. At the 1-year visit, 70% and 97% of the eyes were within ±0.50 D and ±1.00 D of the intended correction. At the 5-year follow-up, 59% and 92% percent of the eyes were within ±0.50 D and ±1.00 D of the intended SE, respectively. At the 5-year visit, the efficacy index was 0.89 ± 0.26 and the safety index was 1.16 ± 0.20. Fifty-four percent of the eyes gained one or more lines of CDVA. Conclusion. SMILE with an intended correction of up to a spherical equivalent of 10 D is safe and effective. However, there is regression of the refractive effect over extended follow-up.


2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Ashraf Ahmed Nossair ◽  
Wael Ahmed Ewais ◽  
Lamia Samy Ali

Purpose.To evaluate the technique of vitreous tap using needle aspiration for management of anterior chamber shallowness during phacoemulsification.Methods.A retrospective study included 26 eyes of 17 patients who underwent phacoemulsification in which vitreous tap was performed using a 27-gauge needle attached to a 5 ml syringe, inserted 3.5 mm from the limbus to aspirate 0.2 ml of liquefied vitreous if a cohesive (OVD) failed to sufficiently deepen the anterior chamber.Results.Preoperative anterior chamber depth was 2.31 ± 0.26 mm, axial length was 21.7 ± 0.67 mm, lens thickness was 4.5 ± .19 mm, and cataract grade was 3.77 ± 1.4. Preoperative CDVA in LogMAR units was 0.98 ± 0.75. Coexisting angle closure glaucoma was present in 7 patients (26.92%) preoperatively. Vitreous needle tap was successful in vitreous removal on the first attempt in 26 eyes (100%). Postoperative follow-up period was 22.88 ± 10.24 (4–39) months. The final postoperative CDVA in LogMAR units was 0.07 ± 0.1, while the final postoperative IOP was 16.54 ± 1.45 mmHg. No complications related to vitreous tap were noted.Conclusion.Vitreous needle tap is a simple, cost-effective, and safe technique for management of shallow anterior chamber in phacoemulsification.


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Zhipeng Yan ◽  
Huamao Miao ◽  
Feng Zhao ◽  
Xiaoying Wang ◽  
Xun Chen ◽  
...  

Purpose. To investigate two-year outcomes of Visian Implantable Collamer Lens with a central hole (ICL V4c) implantation for correcting high myopia.Methods. Sixty-one eyes of 32 patients went through ICL V4c implantation. Safety, efficacy, predictability, and intraocular pressure were evaluated 2 years postoperatively. Anterior chamber volume (ACV), anterior chamber depth (ACD), anterior chamber angle width (ACAW), and vault were measured using a Scheimpflug tomography imaging system.Results. At 2 years, the spherical equivalent refraction decreased from preoperative −14.62 ± 4.29 D to −0.90 ± 0.95 D, with 79% of the eyes within ±0.50 D and 98% within ±1.00 D of the intended correction. The efficacy index was 1.03 ± 0.23, and the safety index was 1.24 ± 0.26. Corrected distance visual acuity (CDVA) remained unchanged in 23% of the eyes, 75% gained one or more lines of CDVA, and 2% lost one line. The ACV, ACD, and ACAW, respectively, decreased from 193.28 ± 29.15 mm3, 3.15 ± 0.23 mm, and 36.51 ± 6.54 degree to 112.48 ± 17.01 mm3, 2.99 ± 0.23 mm, and 22.54 ± 5.27 degree (p=0.0008,  0.008,  and  0.0003, resp.). Intraocular pressure was 15.39 ± 2.88 mmHg before surgery and was 15.86 ± 4.11 mmHg at 2 years (p=0.11).Conclusion. Implantation of ICL V4c is a safe, effective, and predictable procedure for correcting high myopia. Reduction of anterior chamber space after surgery did not induce intraocular pressure increase during the 2-year follow-up.


Sign in / Sign up

Export Citation Format

Share Document