scholarly journals Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia

2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Zhipeng Yan ◽  
Huamao Miao ◽  
Feng Zhao ◽  
Xiaoying Wang ◽  
Xun Chen ◽  
...  

Purpose. To investigate two-year outcomes of Visian Implantable Collamer Lens with a central hole (ICL V4c) implantation for correcting high myopia.Methods. Sixty-one eyes of 32 patients went through ICL V4c implantation. Safety, efficacy, predictability, and intraocular pressure were evaluated 2 years postoperatively. Anterior chamber volume (ACV), anterior chamber depth (ACD), anterior chamber angle width (ACAW), and vault were measured using a Scheimpflug tomography imaging system.Results. At 2 years, the spherical equivalent refraction decreased from preoperative −14.62 ± 4.29 D to −0.90 ± 0.95 D, with 79% of the eyes within ±0.50 D and 98% within ±1.00 D of the intended correction. The efficacy index was 1.03 ± 0.23, and the safety index was 1.24 ± 0.26. Corrected distance visual acuity (CDVA) remained unchanged in 23% of the eyes, 75% gained one or more lines of CDVA, and 2% lost one line. The ACV, ACD, and ACAW, respectively, decreased from 193.28 ± 29.15 mm3, 3.15 ± 0.23 mm, and 36.51 ± 6.54 degree to 112.48 ± 17.01 mm3, 2.99 ± 0.23 mm, and 22.54 ± 5.27 degree (p=0.0008,  0.008,  and  0.0003, resp.). Intraocular pressure was 15.39 ± 2.88 mmHg before surgery and was 15.86 ± 4.11 mmHg at 2 years (p=0.11).Conclusion. Implantation of ICL V4c is a safe, effective, and predictable procedure for correcting high myopia. Reduction of anterior chamber space after surgery did not induce intraocular pressure increase during the 2-year follow-up.

2019 ◽  
Author(s):  
Lingling Niu ◽  
Huamao Miao ◽  
Tian Han ◽  
Lan Ding ◽  
Xiaoying Wang ◽  
...  

Abstract Background: High myopia with shallow anterior chamber depth (ACD < 2.8 mm) is not rare. This observational study aims to: evaluate clinical outcomes after implantation of the Visian Implantable Collamer Lens with a central hole (ICL V4c) in these patients. Methods: A prospective cohort of consecutive 51 eyes of 31 patients (20 to 42 years old) was followed for 15.35 ± 4.90 months (12 to 25 months). The preoperative ACD was 2.74 ± 0.04 mm (2.65 to 2.79 mm). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), intraocular pressure (IOP), manifest refraction, vault, and endothelial cell density (ECD) were measured during the follow-ups after the surgery. Results: All surgeries were performed safely and no complication was observed during the follow-ups. At the last follow-up, the safety index (postoperative CDVA / preoperative CDVA) was 1.33 ± 0.60 and the efficacy index (postoperative UDVA / preoperative CDVA) was 1.14 ± 0.54. After the surgery, no eye had decreased CDVA and 59% (30 eyes) of the eyes gained at least one line. Forty-seven eyes (92%) were within ± 1.0 D and 35 eyes (69%) were within ± 0.5 D of the attempted refraction. The mean postoperative vault was 380.00 ± 152.84 µm (90 to 700µm). The ECD was reduced by 8.38 ± 0.06% compared to the preoperative value (p < 0.001). No significant change was observed in IOP (p = 0.061) at the last follow-up. Ultrasound Biomicroscopy (UBM) showed none of the eyes had trabecular-iris angle closed. Conclusions: In this prospective observational study, ICL V4c implantation in patients with high myopia and shallow ACD achieved satisfying and stable visual outcomes. Its long-term safety and stability require further investigation. Trial Registration: This trial was retrospectively registered on 05/08/2018 under the number (ChiCTR1800017594)


PLoS ONE ◽  
2020 ◽  
Vol 15 (11) ◽  
pp. e0242434
Author(s):  
Yuki Takagi ◽  
Takashi Kojima ◽  
Tomoya Nishida ◽  
Tomoaki Nakamura ◽  
Kazuo Ichikawa

Purpose To predict the anterior chamber volume (ACV) after implantable collamer lens (ICL) implantation based on ICL size and parameters of anterior segment optical coherence tomography (AS-OCT). Design Retrospective study. Methods This study included 222 eyes of 222 patients who underwent ICL implantation at Nagoya Eye Clinic. The patients were divided into two groups: prediction group, for creating the prediction equation (148 eyes, mean age: 32.11 ± 8.04 years), and verification group, for verifying the equation (74 eyes, mean age: 33.03 ± 6.74 years). The angle opening distance (AOD), anterior chamber width (ACW), ACV, anterior chamber depth, lens vault, angle-to-angle distance, angle recess area, and trabecular iris space area were calculated using AS-OCT. A stepwise multiple regression analysis was performed. After the creation of the prediction equation, its accuracy was verified in the verification group. Results The ACV, AOD750, ACW, and ICL size were selected as explanatory variables to predict postoperative ACV. Mean predicted (114.2 ± 21.83 mm3) and actual postoperative ACVs (116.1 ± 25.41 mm3) were not significantly different (P = 0.269); absolute error was 10.59 ± 9.13 mm3. In addition, there was high correlation between actual and predictive ACV (adjusted R2 = 0.6996, p < 0.0001). Bland-Altman plot revealed that there was no addition or proportional error between predicted and actual postoperative ACV. Conclusion Postoperative ACV was accurately predicted using AS-OCT parameters and ICL size. This prediction equation may be useful for making decisions regarding ICL size.


2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Nian Guan ◽  
Xiao-Nong Zhang ◽  
Wan-Jun Zhang

Abstract Background Implantable Collamer lens (ICL) vaulting is one of the most important parameters for the safety, aqueous humor circulation, and lens transparency after ICL implantation. This study aimed to investigate the factors associated with the actual vaulting after refractive EVO-ICL surgery. Methods This retrospective study included patients who underwent EVO-ICL surgery at a tertiary eye hospital between October and December 2019. A RESCAN 700 was used for the intraoperative and CIRRUS HD-OCT was used for postoperative observation of vaulting. Subjective and objective refractions, anterior ocular segment, corneal morphology, intraocular pressure (IOP), anterior chamber volume (ACV), crystalline lens rise (CLR), white-to-white distance (WTW), anterior chamber depth (ACD), axial length, corneal endothelial cell density (ECD), and fundoscopy were examined. A multivariable analysis was performed to determine the factors independently associated with 1-month postoperative vaulting. Results Fifty-one patients (102 eyes) were included. Compared with the eyes with normal vaulting, those with high vaulting had higher preoperative diopter values (P = 0.039), lower preoperative corrected visual acuity (P = 0.006), lower preoperative IOP (P = 0.029), higher preoperative ACD (P = 0.004), lower preoperative CLR (P = 0.046), higher ICL spherical equivalent (P = 0.030), higher intraoperative vaulting (P < 0.001), and lower IOP at 1 month (P = 0.045). The multivariable analysis showed that the only factor independently associated with high vaulting at 1 month after surgery was the intraoperative vaulting value (odds ratio = 1.005, 95% confidence interval: 1.002–1.007, P < 0.001). The intraoperative and 1-month postoperative vaulting values were positively correlated (R2 = 0.562). Conclusions The RESCAN700 system can be used to perform intraoperative optical coherence tomography to predict the vaulting value of ICL at 1 month.


2016 ◽  
Vol 236 (1) ◽  
pp. 43-47 ◽  
Author(s):  
Hussam El Chehab ◽  
Emilie Agard ◽  
Aurélie Russo ◽  
Ygal Boujnah ◽  
Corinne Dot

The objective of this study was to assess the intraocular pressure (IOP) as well as the anatomical modifications of the anterior segment following an aflibercept injection. Patients underwent an aflibercept intravitreal injection (IVI) (0.05 ml) with a 30.5-gauge needle and an antireflux system. IOP was assessed before injection (T0), immediately after (T1), and 5 min (T5), 15 min (T15), and 45 min (T45) after the IVI. Before the IVI and immediately after the T1 measurement, a PENTACAM® acquisition was used to evaluate the anterior chamber parameters (anterior chamber volume, depth and measure of the iridocorneal angle). At T0, IOP was 12.9 ± 1.3 mm Hg. IOP significantly increased after IVI (42.7 ± 3 mm Hg, p < 0.001). IOP returned to baseline at T45 (13.0 ± 1.2 mm Hg, p = 0.877). Anterior chamber volume decreased after IVI (160.6 vs. 168.3 mm3, p = 0.002). No significant changes were found for iridocorneal angle and anterior chamber depth. Aflibercept IVI causes an acute increase in IOP over a short period without iridocorneal angle closure.


2019 ◽  
Vol 30 (3) ◽  
pp. 462-468 ◽  
Author(s):  
Yi Zhu ◽  
Jing Zhang ◽  
Haobin Zhu ◽  
Jili Chen ◽  
Jibo Zhou

Purpose:To evaluate the vault change and anterior segment movement induced by mydriasis in moderate-to-high myopic eyes with implantable collamer lenses (ICL).Setting:Shanghai, ChinaDesign:A prospective consecutive observational study.Methods:A total of 45 eyes of 24 patients with ICL V4 implantation and 128 eyes of 65 patients with ICL V4c implantation were included and analyzed. Anterior chamber depth, posterior corneal endothelium-to-ICL distance, and vault before and after mydriasis were measured by Pentacam (Oculus, Wetzlar, Germany) at 1, 3, and 6 months after surgery.Results:Significant vault increases and anterior chamber depth increases induced by mydriasis were noted in both ICL V4 and V4c groups at 1, 3, and 6 months postoperatively. The corneal endothelium-ICL distance increased significantly in eyes with implanted ICL V4c after mydriasis at 3 and 6 months. Moreover, mydriasis-induced vault increases were greater in the ICL V4 group than in the ICL V4c group at 3 and 6 months. In eyes with implanted ICL V4c, mydriasis-induced vault increases were significantly greater at 1 month than at 3 and 6 months.Conclusion:Mydriasis results in a general vault increase in eyes with implanted ICLs. The adjustment of the pressure equilibrium via the central hole of the ICL V4c has an important role in vault change. The mydriasis-induced vault increases tend toward stability after 3 months postoperatively. Mydriasis is relatively safe in eyes with ICL implantation.


2019 ◽  
Author(s):  
Lingling Niu ◽  
Huamao Miao ◽  
Tian Han ◽  
Lan Ding ◽  
Xiaoying Wang ◽  
...  

Abstract Background: High myopia with shallow anterior chamber depth (ACD less than 2.8 mm) is not rare. This observational study aims to evaluate visual outcomes after implantation of the Visian Implantable Collamer Lens with a central hole (ICL V4c) in these patients. Methods: A prospective cohort of consecutive 51 eyes of 31 patients (20 to 42 years old) was followed for at least 12 months (average 15.35 ± 4.90 months, rangers from 12 to 25 months). The preoperative ACD was 2.74 ± 0.04 mm (2.65 to 2.79 mm). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), intraocular pressure (IOP), manifest refraction, vault, and endothelial cell density (ECD) were measured during the follow-ups after surgery. Results: All surgeries were performed safely and no complication was observed during the follow-up. At the last follow-up, the safety index (postoperative CDVA / preoperative CDVA) was 1.33 ± 0.60 and the efficacy index (postoperative UDVA / preoperative CDVA) was 1.14 ± 0.54. After the surgery, no eye had decreased CDVA and 59% (30 eyes) of the eyes gained at least one line. Forty-seven eyes (92%) were within ± 1.0 D and 35 eyes (69%) were within ± 0.5 D of the attempted refraction. The mean postoperative vault was 380.00 ± 152.84 µm (90 to 700µm). The ECD was reduced by 8.38 ± 0.06% as compared to the preoperative value (p < 0.001). No significant change was observed in IOP (p = 0.061) at the last follow-up. Ultrasound Biomicroscopy (UBM) showed none of the eyes had trabecular-iris angle closed. Conclusions: In this prospective observational study, ICL V4c implantation in patients with high myopia and shallow ACD achieved satisfying and stable visual outcomes. Its long-term safety and stability require further investigation. Trial Registration: This trial was retrospectively registered on 05/08/2018 under the number (ChiCTR1800017594)


2016 ◽  
Vol 2016 ◽  
pp. 1-5 ◽  
Author(s):  
Wakako Ikegawa ◽  
Takashi Suzuki ◽  
Koji Namiguchi ◽  
Shiro Mizoue ◽  
Atsushi Shiraishi ◽  
...  

Purpose. To quantify changes in anterior segment (AS) parameters after laser peripheral iridotomy (LPI) using AS-optical coherence tomography (OCT) of iris bombe. Method. AS images of eight eyes were captured before and after iris bombe and more than 2 weeks after LPI (post-LPI) using AS-OCT. We compared the following AS parameters: anterior chamber depth (ACD), anterior chamber volume (ACV), iris curvature (IC), iris thickness at 500 μm from the scleral spur (IT-1) in the middle between the iris root and pupillary margin (IT-2) and 500 μm from the pupillary margin (IT-3) to the anterior chamber angle (ACA) (angle opening distance [AOD750]), and trabecular iris space area. Results. Mean IT-1 and IT-3, but not IT-2, were lower after iris bombe (IT-1, P=0.001; IT-2, P=0.081; and IT-3, P=0.001). There were no significant differences between ACD at pre-LPI and before iris bombe (P=0.096). The mean ACV and AOD750 of iris bombe increased at post-LPI (ACV, P<0.01, and AOD750, P<0.05). The mean IT-1, IT-2, and IT-3 increased at post-LPI (all, P≤0.01). IC decreased at post-LPI (P<0.001), and ACD at post-LPI did not change. Conclusions. The iris extends and becomes thinner during iris bombe. LPI during bombe decreases the IC and increases the ACV and ACA.


2020 ◽  
pp. bjophthalmol-2020-315852
Author(s):  
Yu Jiang ◽  
Wei Wang ◽  
Lanhua Wang ◽  
Mingguang He

PurposeTo assess the association of anterior segment optical coherence tomography (AS-OCT) parameters and 5-year incident narrow angle in China.MethodsThis was a prospective cohort study of people aged 50 and older residing in Liwan District, Guangzhou, China. Random clustering sampling was used to identify adults aged 50 years and older in Liwan District, Guangzhou. In 2008 and 2013, this study was repeated and added AS-OCT imaging under dark and light conditions. Customised software (ZAAP) was used to analyse horizontal AS-OCT scans. Angle opening distance (AOD), trabecular iris space area (TISA), anterior chamber volume (ACV) and maximal iris thickness (ITM) were measured. Multiple logistic regression analysis models were used to investigate the associations of the final angle status with baseline AS-OCT parameters. ORs and 95% CIs were calculated.ResultsOf the 220 subjects with eligible AS-OCT images and gonioscopic results in 2008, the response rate was 77.3%. A total of 27 (15.9%) subjects developed narrow angles and 143 (84.1%) had open angles on gonioscopy in 2013. Subjects developed narrow angles had greater spherical equivalent and shallower anterior chamber depth, smaller angle parameters, thicker IT750 and ITM, smaller anterior chamber parameters, greater lens vault, and smaller dynamic parameters (ΔITM, ΔACA, ΔACV) at baseline. After adjusting confounders, the predictors of incident narrow angles included smaller AOD750, TISA750, ΔACA and greater ITM, ΔIarea.ConclusionsIncident narrow angles were associated with smaller anterior ocular dimensions, thicker iris and smaller light-to-dark changes at baseline. These findings can help in early diagnosis in this population.


Sign in / Sign up

Export Citation Format

Share Document