Myopic lasik outcomes: comparison of three different femtosecond lasers and a mechanical microkeratome using the same excimer laser

2019 ◽  
Author(s):  
Juan Gros-Otero ◽  
Isabel Rodriguez-Perez ◽  
Miguel A. Teus ◽  
Andreas Katsanos ◽  
Dimitrios G. Mikropoulos ◽  
...  

Abstract BACKGROUND To compare the influence of four different microkeratomes on myopic LASIK outcomes. METHODS Retrospective, observational cohort study. We compared 134 eyes treated with the IntraLase 60 kHz, 112 eyes treated with the Femto LDV Z6, 206 eyes treated with the FS200 and 98 eyes treated with the Hansatome zero compression microkeratome. All eyes were operated using the same surgical protocol with the same excimer laser (Wavelight Allegretto) and were allocated in refraction-matched groups. Uncorrected distance visual acuity, best corrected distance visual acuity and residual refraction were evaluated 1 and 7 days, 1 and 3 months postoperatively. RESULTS One day and one week postoperatively, uncorrected distance visual acuity was significantly lower in the FS200 group compared to others (P=0.0001). This difference disappeared at the 1- and 3-month postoperative visits. Significant differences were found among groups in terms of safety index (P=0.0001), residual sphere (P=0.0001) and residual cylinder (P=0.02) at the 3-months postoperative visit. No significant differences were found in corrected distance visual acuity or efficacy index. CONCLUSIONS According to our results, a slight delay in visual restoration after FS200 LASIK surgery might be expected. This delay was statistically significant at 1 day and 1 week postoperatively, but there were no differences from the 1-month visit onwards.

2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Isabel Rodríguez-Pérez ◽  
Juan Gros-Otero ◽  
Miguel A. Teus ◽  
Rafael Cañones ◽  
Montserrat García-González

Abstract Background To compare the visual and refractive outcomes after myopic LASEK using three different excimer lasers and standardized surgical and mitomycin C (MMC) application protocols. Methods In this retrospective, observational cohort study, we examined 122 eyes treated with Allegretto, 135 eyes treated with Esiris and 137 eyes treated with Technolas excimer lasers. All eyes were treated under the same surgical protocol, and a standardized MMC dosage was used. The three groups were refraction-matched, and both visual and refractive outcomes were evaluated at 1 and 7 days and 1 and 3 months after surgery. Results At 3 months postsurgery, Allegretto provided significantly better outcomes than Esiris and Technolas in terms of postoperative uncorrected distance visual acuity (UDVA) (1.11 ± 0.2 vs 1.01 ± 0.2 vs 0.98 ± 0.2) (P = 0.0001), corrected distance visual acuity (CDVA) (1.13 ± 0.2 vs 1.10 ± 0.1 vs 1.04 ± 0.2) (P = 0.0001), residual sphere (− 0.01 ± 0.2 vs + 0.29 ± 0.7 vs + 0.27 ± 0.6) (P = 0.0001), and efficacy index (0.99 ± 0.2 vs 0.90 ± 0.2 vs 0.91 ± 0.2) (P = 0.0004). Conclusions We found slightly better visual and refractive outcomes in the Allegretto group at 3 months post-op after LASEK with MMC to correct myopia.


2017 ◽  
Vol 102 (8) ◽  
pp. 1122-1126 ◽  
Author(s):  
Alex L K Ng ◽  
George P M Cheng ◽  
Victor C P Woo ◽  
Vishal Jhanji ◽  
Tommy C Y Chan

BackgroundWe described a modified ‘hydroexpression’ technique for the lenticule removal during small-incision lenticule extraction (SMILE) surgery and compared the results with conventional forceps method.MethodsThis was a retrospective, comparative study of 50 patients who underwent SMILE surgery by the same surgeon. We compared the 1-week and 3-months postoperative results after SMILE using the hydroexpression technique with the conventional forceps technique. Main outcome measures included uncorrected distance visual acuity, corrected distance visual acuity, refractive accuracy, safety index and efficacy index.ResultsThe baseline characteristics were comparable between both groups. At postoperative 1 week, the safety index in forceps and hydroexpression group was 0.93±0.11 and 0.97±0.10, respectively (P=0.246). At 3 months, they were 1.00±0.06 and 0.99±0.09 (P=0.850). For efficacy indices, at 1 week they were 0.84±0.17 and 0.91±0.17 (P=0.158). At 3 months, they were 0.92±0.13 and 0.94±0.19 (P=0.624). All eyes aimed for a plano target. 96% in forceps group and 90% in hydroexpression group were within ±0.50 dioptre (D) in spherical equivalent refraction (SEQ) correction at postoperative 3 months (P=0.567). The mean errors of SEQ correction were −0.10±0.21 D in forceps group and −0.08±0.30 D in hydroexpression group (P=0.705).ConclusionHydroexpression was simple and safe and had early results comparable to the conventional forceps technique. This technique was particularly useful for cases with more adhesions between lenticule and anterior cap, thin lenticule cases and for the inexperienced SMILE surgeons.


Author(s):  
Isaak R. Fischinger ◽  
Jascha Wendelstein ◽  
Kristin Tetz ◽  
Matthias Bolz ◽  
Manfred R. Tetz

Abstract Purpose To evaluate the influence of the type of the keratectasia and preoperative keratometry readings on the efficacy of implantation of iris-fixated phakic anterior chamber intraocular lenses (pIOL) in patients with keratoconus. Methods In this retrospective study, iris-fixated pIOLs (Artisan/Artiflex (Ophtec®), Verisyse/Veriflex (AMO®)) were implanted in 38 eyes of 22 patients with stable keratoconus. Thirty-six eyes underwent corneal crosslinking (CXL) prior to the lens implantation. The refractive outcome was evaluated 6 weeks postoperatively and the influence of preoperative refraction and topo- and tomographical factors were analyzed. Results The mean postoperative uncorrected distance visual acuity (UDVApost) was 0.25 ± 0.15 logMAR and was not statistically different from the mean preoperative corrected distance visual acuity (CDVApre), which was 0.24 ± 0.13 logMAR. Twenty-seven eyes (71%) reached UDVApost/CDVApre ≥ 1 (efficacy index), whereas patients with PMD-like ectasia (n = 14) showed significantly (p = 0.003) higher efficacy index (100%) than patients diagnosed with keratoconus (n = 24) (54%). Higher eccentricity of the maximum posterior elevation showed a significant beneficial influence on the efficacy index (p = 0.021). Furthermore, a higher Amsler-Krumeich stage and preoperative MAE were correlated with a worse UDVApost. The mean absolute spherical equivalent was significantly decreased from 5.71 ± 4.96 D to 1.25 ± 1.20 D (p < 0.001). No significant difference was found in endothelial cell count. Conclusion The results indicate that the implantation of phakic iris-fixated anterior chamber IOLs is a reasonable refractive option for patients with keratoconus. Keratoconus patients with a pellucidal marginal degeneration (PMD)-like appearance ectasia seem to benefit most from such procedures.


2018 ◽  
Vol 29 (2) ◽  
pp. 171-177 ◽  
Author(s):  
Jing Zhao ◽  
Dongqiang Luo ◽  
Yong Sun ◽  
Lingling Niu ◽  
Feng Zhao ◽  
...  

Purpose: To investigate the safety and efficacy of implanting a posterior chamber implantable collamer lens with a central hole in cases of high myopia with peripheral primary iris or ciliary body cysts. Methods: A total of 37 eyes of 19 patients with primary iris or ciliary body cysts detected by ultrasonic biological microscope were included, with spherical powers of −10.26 ± 3.28 D and cylinder powers of −1.71 ± 1.18 D. Each patient received ultrasonic biological microscope and a routine examination before implantation of the implantable collamer lens. A routine postoperative follow-up was performed to observe changes in the iris or ciliary body cyst, ranging from 3 to 18 months. Results: There were no complications. At the last follow-up, 56.8% (21/37) of eyes achieved the same corrected distance visual acuity as their preoperative measurements, 43.2% of eyes were enhanced by ≥1 line, and no patients’ corrected distance visual acuity declined. The efficacy index and safety index were 0.95 and 1.11, respectively. After 18 months, 66.7% of the spherical equivalents were between ±0.5 D with 100% between ±1.0 D. The postoperative mean spherical equivalents at 1, 3, 6, 12, and 18 months were −0.45 ± 0.31 D, −0.39 ± 0.29 D, −0.36 ± 0.30 D, −0.39 ± 0.38 D, and −0.48 ± 0.23 D (p = 0.789). The vaults were 516 ± 140, 548 ± 124, 498 ± 133, 582 ± 161, and 557 ± 110 μm (p = 0.355). There were no changes in size (p > 0.05), number, or position of the iris or ciliary body cysts. Conclusion: Implantable collamer lens implantation is safe and effective for highly myopic patients with peripheral primary iris and ciliary body cysts. The cysts did not change after operation in this study.


2018 ◽  
Vol 30 (1) ◽  
pp. 139-146 ◽  
Author(s):  
Guilherme Andrade do Nascimento Rocha ◽  
Paulo Ferrara de Almeida Cunha ◽  
Leonardo Torquetti Costa ◽  
Luciene Barbosa de Sousa

Importance: This study shows that a newer long-arc length intrastromal corneal ring segment is efficient and safe for keratoconus treatment. Background: To evaluate visual, tomographic results and complications of a 320-degree intrastromal corneal ring segment implantation with the femtosecond laser for keratoconus treatment. Design: A prospective, nonrandomized, and interventional study. Participants: A total of 34 eyes of 31 patients diagnosed with keratoconus were enrolled. Methods: Patients were divided into two groups based on the strategy used for 320-degree intrastromal corneal ring segment thickness selection. In one group, this selection was based on spherical equivalent (SE group) and in the other on the mean asphericity (Q group). The uncorrected and corrected distance visual acuities, spherical equivalent, K1, K2, Km, Kmax, and mean asphericity ( Q) on corneal tomography were evaluated preoperatively and at 3 and 6 months postoperatively. For astigmatism improvement, we analyzed the corneal tomographic vectorial astigmatism change preoperatively and at 6 months postoperatively. The mean follow-up period was 6.63 ± 0.96 months. Results: The mean uncorrected distance visual acuity and corrected distance visual acuity improved with a significant spherical equivalent improvement ( p < 0.05), with no differences between the 320-degree intrastromal corneal ring segment groups. All corneal tomographic parameters improved significantly ( p < 0.05) between the preoperative and postoperative intervals, with a significant better performance when we used spherical equivalent for the 320-degree intrastromal corneal ring segment thickness selection. Finally, the mean vectorial corneal tomographic astigmatism significantly improved after 6 months, again with no differences between groups. Conclusion: This study suggests that implanting a 320-degree intrastromal corneal ring segment is a safe and effective procedure for treating patients with keratoconus. It also suggests that for thickness selection spherical equivalent is the better strategy.


Author(s):  
Rosane de Oliveira Corrêa ◽  
Ana Laura Caiado Canedo ◽  
Rozalia Beildeck ◽  
Marcella Quaresma Salomão ◽  
Penelope Burle de Politis

ABSTRACT Purpose To report the clinical course of a typical young patient presenting with asymmetric keratoconus (KC), that demonstrates that stabilization of the ectatic process is possible without cross-linking (CXL) procedure. Methods Case report and review of the literature. Results A 17-year-old male patient was referred due to the diagnosis of keratoconus. Patient complained of loss of vision in the left eye (OS). Uncorrected distance visual acuity (UDVA) was 20/25+ in the right eye (OD) and 20/80 in the left eye; wavefront-assisted manifest refraction gave best corrected distance visual acuity (CDVA) of 20/20 in OD and 20/40 in OS. The diagnosis of keratoconus was confirmed with Placido disk-based topography (Oculus Keratograph 4), and Pentacam HR corneal tomography (Oculus Optikgeräte GmbH, Wetzlar, Germany). Femtosecond laser-assisted intracorneal ring segment (ICRS) implantation was performed in the left eye and treatment for allergy was prescribed for both eyes, along with patient education and advice not to rub the eyes. After 3 months, significant improvement was observed on UDVA (20/30) and CDVA (20/20) in the left eye. Topometric and tomographic stability of ectasia was observed in the right eye in a 4-year follow-up. Conclusion Intracorneal ring segment caused significant regularization of the corneal shape and improvement on visual acuity. Ectasia stability was achieved with no need for CXL, despite the patient's young age. This case raises the point that the indication of CXL for every keratoconic patient should be reconsidered. How to cite this article de Oliveira Corrêa R, Canedo ALC, Beildeck R, Salomão MQ, de Politis PB, Ambrósio R Jr. Longterm Stability of Ectasia in a Young Patient with Asymmetric Keratoconus. Int J Kerat Ect Cor Dis 2015;4(2):66-68.


2020 ◽  
Vol 1 (2) ◽  
pp. 113-116
Author(s):  
Nasser A Alsabaani ◽  
◽  
Salem Almalki ◽  

AIM: To evaluate the safety, refractive outcomes and vision after phakic posterior chamber implantable collamer lens (ICL) after keratoplasty (KP). METHODS: This retrospective single center study evaluated 32 (35 eyes) patients who received an ICL for myopia and/or astigmatism after keratoplasty. Patients underwent ICL surgery if they were unable to wear glasses or contact lenses and excimer laser surgery was contraindicated. Data were collected on uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction and complications. Data were analyzed for the preoperative and last postoperative visits (16.7±13mo) (P<0.05). RESULTS: Preoperatively, spherical equivalent (SE) ranged from -4.00 to -20.00 D and cylinder from -2.00 to -9.00 D. The mean SE decreased statistically significantly from -11.41±3.62 D preoperatively to -1.95±1.78 D postoperatively (P<0.0001). Mean UDVA increased statistically significantly from 20/400 preoperatively to 20/25 postoperatively (P<0.0001). There was a mean improvement in postoperative CDVA of 1.5 lines compared to preoperatively, 37% of eyes had an increase of 2 or more lines. One eye (2.8%) lost ≥1 line of CDVA. There were no intraoperative or postoperative complications. CONCLUSION: Posterior chamber phakic intraocular lens implantation is a safe and effective treatment for post-keratoplasty myopia and astigmatism in patients unable to wear spectacles or contact lenses and where corneal refractive surgery is contraindicated.


2019 ◽  
Vol 30 (6) ◽  
pp. 1278-1286 ◽  
Author(s):  
Suphi Taneri ◽  
Saskia Kießler ◽  
Anika Rost ◽  
Tim Schultz ◽  
H Burkhard Dick

Purpose: To compare the visual and refractive outcomes of small incision lenticule extraction and advanced surface ablation for low myopia or myopic astigmatism. Methods: Retrospective, observational case series of our first 50 consecutive small incision lenticule extraction patients compared to refraction-matched 50 advanced surface ablation treatments with attempted spherical equivalent correction ⩽−3.5 D, astigmatism ⩽−1.5 D, and corrected distance visual acuity of 1.0 (decimal scale) or better. Only one eye per patient was included. Results: Small incision lenticule extraction: mean attempted spherical equivalent correction was −2.80 ± 0.63 D. Uncorrected distance visual acuity was 0.85 and 1.0 at days 1 and 5, respectively. At 3 months, mean spherical equivalent refraction was 0.02 ± 0.32 D (range: −0.5 to +0.75 D), mean cylinder was −0.24 ± 0.21 D (range: 0 to −0.75 D), mean uncorrected distance visual acuity was 1.27, mean efficacy index was 0.96, and mean safety index was 1.05. Uncorrected distance visual acuity was same or better than corrected distance visual acuity in 96%, astigmatism ⩽0.5 D in 98% and ⩽1 D in 100% of eyes, respectively. Advanced surface ablation: mean attempted spherical equivalent correction was −2.75 ± 0.5 D. Uncorrected distance visual acuity was 0.72 and 0.61 at days 1 and 5, respectively. At 3 months, mean spherical equivalent refraction was 0.22 ± 0.32 D, mean cylinder was −0.27 ± 0.27 D, mean uncorrected distance visual acuity was 1.21, mean efficacy index was 1.03, and mean safety index was 1.08. Conclusion: Small incision lenticule extraction for low myopia was found to be safe and effective with outcomes at 3 months similar to those obtained with advanced surface ablation while offering a quicker visual recovery.


2019 ◽  
Vol 30 (5) ◽  
pp. 917-927
Author(s):  
Suphi Taneri ◽  
Saskia Kießler ◽  
Anika Rost ◽  
Tim Schultz ◽  
H Burkhard Dick

Purpose: Excimer laser-based refractive procedures can have less predictable results when used for correcting high myopia than when used for moderate myopia. Small incision lenticule extraction might overcome this weakness. However, small incision lenticule extraction is only Food and Drug Administration approved for use in myopic eyes up to −8 D with astigmatism of −3 D or less. We report outcomes of small incision lenticule extraction in highly and moderately myopic eyes and compare these to modern laser-assisted in situ keratomileusis. Methods: Retrospective, observational consecutive case series. Inclusion criteria: attempted myopic spherical correction ⩾−8 or−3 to −7.75 D with astigmatism ⩽−3 D, and corrected distance visual acuity of 1.0 (decimal scale) or better. Results: A total of 62 highly myopic and 407 moderately myopic eyes were included. At 3 months postoperatively, the highly myopic eyes had a mean spherical equivalent refraction of −0.28 ± 0.41 D (range: −1.13 to +0.75 D). Mean uncorrected distance visual acuity was 1.0. Mean efficacy index was 0.84. Mean safety index was 1.03. Uncorrected distance visual acuity same or better than corrected distance visual acuity: 61%. Astigmatism was ⩽0.5 D in 90% and ⩽1 D in 100%. The results in the moderately myopic eyes were comparable. Conclusion: We found equally good visual and refractive outcomes after small incision lenticule extraction for the correction of high and of moderate myopia combined with an astigmatic correction of up to 3 D, respectively.


2018 ◽  
Vol 30 (1) ◽  
pp. 125-131
Author(s):  
Cristina Peris-Martínez ◽  
Inmaculada Bueno-Gimeno ◽  
Izaskun Alvarez-Arana ◽  
David P Piñero ◽  
Andrés Gené-Sampedro

Purpose: To evaluate the visual, refractive, topographic, pachymetric, and biomechanical outcomes after intracorneal ring segment implantation in corneas with post-LASIK ectasia. Methods: Retrospective longitudinal study enrolling 26 eyes of 22 patients with post-LASIK ectasia and undergoing intracorneal ring segment implantation (KeraRing®, Mediphacos) using a 60-kHz femtosecond laser (IntraLase®, IntraLase Corp.) for corneal tunnelization. Visual, refractive, anterior, and posterior corneal topographic (Pentacam HR, Oculus), pachymetric, and corneal biomechanical changes (Ocular response Analyzer, Reichert) were evaluated during a 12-month follow-up. Vector analysis of astigmatic changes was performed. Results: A statistically significant reduction of sphere (p = 0.043) was observed at 1 month after surgery, with a significant improvement of uncorrected distance visual acuity associated (p = 0.019). Likewise, a significant reduction of anterior corneal power measurements (p ⩽ 0.014) and steepest posterior keratometric reading (p = 0.006) were observed at 1 month postoperatively, with no significant changes afterwards (p ⩾ 0.133). No significant changes were observed in manifest cylinder (p ⩾ 0.175), corrected distance visual acuity (p ⩾ 0.174), flattest posterior keratometric measurement (p ⩾ 0.282), volumetric measurements (p ⩾ 0.051), and corneal biomechanical parameters (p ⩾ 0.068). Vector analysis revealed an initial trend to overcorrection of astigmatism, with a trend to undercorrection at the end of follow-up and a significant variability in the outcome achieved in each patient. Conclusion: The implantation of KeraRing segments in post-LASIK corneal ectasia generates a significant modification of spherical refraction and a visual improvement due to a central corneal flattening generated. More refined nomograms of implantation in these cases should be developed to achieve a more predictable correction of astigmatism.