scholarly journals Relationship of Anthropometric Indices with Rate Pressure Product, Pulse Pressure and Mean Arterial Pressure Among Secondary Adolescents of 12-17 Years

Author(s):  
Godfrey Katamba ◽  
Abdul Musasizi ◽  
Mivule Abdul Kinene ◽  
Agnes Namaganda ◽  
Francis Muzaale

Abstract Objectives: To determine the correlation between anthropometric indices and the selected hemodynamic parameters among secondary adolescents aged 12-17 years.Results: Our findings showed weak positive correlation between generally body surface area, neck circumference and conicity index with the hemodynamic parameters (systolic blood pressure, diastolic blood pressure, resting pulse rate, mean arterial pressure, rate pressure product and pulse pressure). However, the ponderosity index, body mass index and waist hip ratio showed negative weak correlations with the hemodynamic parameters. There was a significant difference in pulse pressure among the BMI categories. All parameters showed significant (p<0.05) differences across the categories of neck circumference and waist hip ratio. Generally, in multivariate regression analysis, anthropometric indices showed significant prediction of the hemodynamic parameters.

2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Godfrey Katamba ◽  
Abdul Musasizi ◽  
Mivule Abdul Kinene ◽  
Agnes Namaganda ◽  
Francis Muzaale

Abstract Objectives To determine the correlation between anthropometric indices and the selected hemodynamic parameters among secondary adolescents aged 12–17 years. Results Our findings showed weak positive correlation between generally body surface area, neck circumference and conicity index with the hemodynamic parameters (systolic blood pressure, diastolic blood pressure, resting pulse rate, mean arterial pressure, rate pressure product and pulse pressure). However, the ponderosity index, body mass index and waist hip ratio showed negative weak correlations with the hemodynamic parameters. There was a significant difference in pulse pressure among the BMI categories. All parameters showed significant (p < 0.05) differences across the categories of neck circumference and waist hip ratio. Generally, in multivariate regression analysis, anthropometric indices showed significant prediction of the hemodynamic parameters.


2020 ◽  
Author(s):  
Godfrey Katamba ◽  
Abdul Musasizi ◽  
Mivule Abdul Kinene ◽  
Agnes Namaganda ◽  
Francis Muzaale

Abstract Background: Anthropometric indices are highly associated with cardiovascular events. However, there correlation with hemodynamic parameters among adolescents is still wanting. Study purpose: To determine the correlation between anthropometric indices and the selected hemodynamic parameters among secondary adolescents aged 12-17 years.Methods: In this study, we present data of 485 secondary school adolescents aged 12-17 years. Height, weight, waist circumference, hip circumference and neck circumference were measured using standard protocol. Conicity index, body mass index, ponderosity index and body surface area, were computed using standard formulae. Blood pressure was measured using a digital automated blood pressure machine. The rate pressure product was determined as product of heart rate and systolic blood pressure, pulse pressure as the difference between systolic blood pressure and diastolic pressure while mean arterial pressure was the sum of diastolic pressure and pulse pressure. Comparisons of hemodynamic parameters across the anthropometric index’s categories were done using a one-way ANOVA and an unpaired t-test while correlation analysis was done using Pearson correlation coefficient at 95% confidence interval.Results: Our findings showed weak positive correlation between generally body surface area, neck circumference and conicity index with the hemodynamic parameters (systolic blood pressure, diastolic blood pressure, resting pulse rate, mean arterial pressure, rate pressure product and pulse pressure). However, the ponderosity index, body mass index and waist hip ratio showed negative weak correlations with the hemodynamic parameters. There was a significant difference in pulse pressure among the BMI categories. All parameters showed significant (p<0.05) differences across the categories of neck circumference and waist hip ratio. Generally, in multivariate regression analysis, anthropometric indices showed significant prediction of the hemodynamic parameters.Conclusion: Generally, a weak positive correlation between anthropometric indices and the hemodynamic parameters.


2012 ◽  
Vol 9 (4) ◽  
pp. 238-243 ◽  
Author(s):  
G S Shrestha ◽  
M N Marhatta ◽  
R Amatya

Background Laryngoscopy and intubation increases blood pressure and heart rate. Objective The study aims to investigate the effect and safety of gabapentin, esmolol or their combination on the haemodynamic response to laryngoscopy and intubation. Methods A total of 72 patients undergoing elective surgery were randomly allocated to one of the four groups. First study drug was administered orally as gabapentin 1200mg or placebo. Second study drug was administered intravenously as esmolol 1.5mg/kg or normal saline. Heart rate, rate pressure product, systolic blood pressure and mean arterial pressure were recorded at baseline and at zero, one, three and five minutes after tracheal intubation. Results Baseline values were compared with the values at various time intervals within the same group. In group PE (placebo, esmolol), there was significant decrease in heart rate and rate pressure product at five minutes. In group GN (gabapentin, normal saline), there was significant decrease in systolic blood pressure and mean arterial pressure at five minutes. In group GE (gabapentin, esmolol), there was significant decrease in heart rate at zero, three and five minutes. Systolic blood pressure, mean arterial pressure and rate pressure product was significantly lower at three and five minutes. In group PN (placebo, normal saline), there was significant increase in heart rate at zero, one, three and five minutes; systolic blood pressure at zero and one minutes; mean arterial pressure at zero and one minutes & rate pressure product at zero, one and three minutes. In group GN (gabapentin, normal saline), there was significant increase in heart rate at zero, one and three minutes & rate pressure product at zero, one and three minutes. In group PE (placebo, esmolol), there was significant increase in systolic blood pressure at zero and one minutes & mean arterial pressure at zero and one minutes. However, in group GE (gabapentin, esmolol) none of the variables showed statistically significant increase at any time. Inter-group comparison was made for each time point. At zero minute, there was significant difference in heart rate between groups PN and GE, GN and PE & GN and GE Significant difference was also noted in rate pressure product between PN and GE at zero minute. At one minute there was difference in heart rate between PN and PE, PN and GE, GN and PE & between GN and GE. Significant difference was observed in rate pressure product between PN and PE & between PN and GE at one minute. No significant side effects of the study drugs were observed. ConclusionsCombination of gabapentin and esmolol in this study design is safe and better attenuates both the pressor and tachycardic response to laryngoscopy and intubation, than either agent alone.DOI: http://dx.doi.org/10.3126/kumj.v9i4.6336 Kathmandu Univ Med J 2011;9(4):238-43 


2020 ◽  
Vol 9 (1) ◽  
pp. 8-15
Author(s):  
Arya Justisia Sani ◽  
Ardhana Tri Arianto ◽  
Muhammad Husni Thamrin

Latar Belakang dan Tujuan: Peningkatan respon hemodinamik yang disebabkan oleh nyeri dapat menyebabkan peningkatan aliran darah otak dan tekanan intrakranial. Blok scalp pada kraniotomi menumpulkan respon hemodinamik karena rangsangan nyeri serta mengurangi penambahan analgesi lain. Penelitian ini bertujuan untuk mengetahui efektifitas blok scalp sebagai analgetik pada kraniotomi.Subjek dan Metode: Penelitian ini menggunakan uji klinik acak tersamar ganda pada 36 pasien dengan status fisik ASA 1–3 dilakukan operasi kraniotomi eksisi dan memenuhi kriteria inklusi. Sampel dibagi menjadi kelompok I (dengan blok scalp) dan kelompok II (tanpa blok scalp). Blok dilakukan sesaat setelah induksi anestesi. Digunakan levobupivakain 0,375% sebanyak 3 ml tiap insersi, pada masing-masing saraf. Tekanan darah, tekanan arteri rata-rata, detak jantung sebelum intubasi dan setelah intubasi, pemasangan pin, insisi kulit dan insisi duramater serta total kebutuhan fentanyl tambahan dicatat. Data yang diperoleh dianalisis dengan program komputer SPSS versi 17 lalu diuji menggunakan uji Kruskal-Wallis atau One-way ANOVA. Batas kemaknaan yang diambil adalah p < 0,05.Hasil: Selama kraniotomi, detak jantung, tekanan darah, tekanan arteri rata-rata secara signifikan lebih tinggi pada pasien tanpa blok scalp terutama pada saat pemasangan pin. Hasil uji statistik menunjukkan perbedaan signifikan, penambahan fentanyl pada pasien dengan blok scalp lebih sedikit dibandingkan tanpa blok scalp, p=0,000 (p<0,05).Simpulan: Blok scalp levobupivakain efektif dalam menurunkan respon hemodinamik terutama pada saat pemasangan pin. Pasien kraniotomi dengan blok scalp membutuhkan penambahan fentanyl lebih sedikit. Differences on Hemodynamic Response with Levobupivacaine Scalp Block in Craniotomy SurgeryAbstractBackground and Objective: Increased hemodynamic response caused by pain can lead to increased cerebral blood flow and intracranial pressure. Scalp block in craniotomy blunts hemodynamic response due to pain and reduce other analgesics addition. This study aims to determine effectiveness of scalp blocks as analgesic in craniotomy.Subject and Method: This study used a double-blind randomized clinical trial in 36 patients with physical status ASA 1-3 who underwent craniotomy and met inclusion criteria. Samples were divided into group I (with scalp block) and group II (without scalp block). Scalp Block was performed right after anesthesia induction. Using levobupivacaine 0.375% 3 ml for each insertion. Blood pressure, mean arterial pressure, heart rate before and after intubation, during pin placement, skin incision and duramater incision and total need for additional fentanyl were recorded. SPSS version 17 was used and data were analysed using Kruskal-Wallis or One-way ANOVA. Statistical significance was accepted at p < 0.05.Result: During craniotomy, heart rate, blood pressure, mean arterial pressure were significantly higher in patients without scalp block especially during pin placement. Statistical test showed significant difference, additional fentanyl in patients with scalp blocks was lesser, p = 0.000 (p <0.05). Conclusion: Levobupivacaine scalp block was effective to blunt hemodynamic response especially during pin placement. Scalp block also decreased additional fentanyl in craniotomy.


2020 ◽  
pp. 000348942096282
Author(s):  
Cassie L. Dow ◽  
Anders W. Sideris ◽  
Ravjit Singh ◽  
Mitchell H. Giles ◽  
Catherine Banks ◽  
...  

Objective: This study aimed to test the non-inferiority of topical 1:1000 epinephrine compared to topical 1:10 000 with regard to intraoperative hemodynamic stability, and to determine whether it produced superior visibility conditions. Methods: A single-blinded, prospective, cross-over non-inferiority trial was performed. Topical 1:1000 or topical 1:10 000 was placed in 1 nasal passage. Hemodynamic parameters (heart rate, systolic and diastolic blood pressures, and mean arterial pressure) were measured prior to insertion then every minute for 10 minutes. This was repeated in the contralateral nasal passage of the same patient with the alternate concentration. The surgeon graded the visualization of each passage using the Boezaart Scale. The medians of the greatest absolute change in parameters were compared using a Wilcoxon Rank-Signed test and confidence intervals were calculated using a Hodges-Lehman test. The non-inferiority margin was pre-determined at 10 bpm for heart rate and 10 mmHg for blood pressures. A Wilcoxon Rank-Signed test was used to assess superiority in visualization. Results: Thirty-two patients were enrolled and after exclusions, nineteen were assessed (mean age = 35.63 ± 12.49). Differences in means of greatest absolute change between the 2 concentrations were calculated (heart rate = 2.49 ± 1.20; systolic = −1.51 ± 2.16; diastolic = 2.47 ± 1.47; mean arterial pressure = 0.07 ± 1.83). In analyses of medians, 1:1000 was non-inferior to the 1:10 000. There was a significant difference (–0.58 ± 0.84; P = .012) in visualization in favor of topical 1:1000. Conclusion: Topical 1:1000 epinephrine provides no worse intraoperative hemodynamic stability compared to topical 1:10 000 but affords superior visualization and should be used to optimize surgical conditions.


2005 ◽  
Vol 15 (5) ◽  
pp. 477-480 ◽  
Author(s):  
Ugo Giordano ◽  
Salvatore Giannico ◽  
Attilio Turchetta ◽  
Fatma Hammad ◽  
Flaminia Calzolari ◽  
...  

We measured resting and exercise haemodynamics, as well as 24-hour ambulatory blood pressure, so as to study the influence on development of hypertension in children after repair of coarctation by either construction of a subclavian flap or end-to-end anastamosis. The patients in both groups were studied a mean time of 13 years after surgery. Thus, we divided 43 children who had undergone surgical repair of coarctation, and who were not on antihypertensive therapy, into a group of 22 patients who had undergone subclavian flap repair, with a mean age of 14 plus or minus 2.6 years, and another group of 21 patients undergoing end-to-end anastomosis, with a mean age of 13.5 plus or minus 3.9 years. We examined blood pressure at rest and during exercise, along with the measurement of cardiac output using impedance cardiography, and during 24-hour ambulatory monitoring. We recorded systolic and diastolic blood pressures, pulse pressure, cardiac output and total peripheral vascular resistance at rest and at peak exercise. During ambulatory monitoring, we measured mean pressures over 24 hours, in daytime and nighttime, 24-hour pulse pressure, and 24-hour mean arterial pressure. Student's t test was used to judge significance, accepting this when p was less than 0.05. The group repaired using the subclavian flap showed significantly disadvantageous differences for diastolic blood pressure at rest, systolic blood pressure at peak exercise and for 24-hour systolic and diastolic blood pressure, 24-hour mean arterial pressure, and daytime and nighttime systolic blood pressure during ambulatory monitoring. Our findings suggest that, after repair using the subclavian flap in comparison to end-to-end anastomosis, patients show a higher incidence of late hypertension, both during exercise and ambulatory monitoring. The data indicate different residual aortic stiffnesses, these being lower after end-to-end anastomosis, which may be due to the greater resection of the abnormal aortic tissue when coarctation is repaired using the latter technique.


2019 ◽  
Vol 105 (4) ◽  
pp. 390-394
Author(s):  
Katherine Kirupakaran ◽  
Paula de Sousa ◽  
Celine Le Roux ◽  
Lauren Redwood ◽  
Heike Rabe ◽  
...  

ObjectiveTo evaluate whether changing dopamine infusions every 12 hours and preparing these infusions 30 min before administration reduces blood pressure fluctuations in preterm and term neonates.DesignThis was a retrospective study using data from live patients on the neonatal unit and prospective study exploring stability of infusions in a laboratory-based neonatal ward simulation.SettingSingle-centre study in a tertiary neonatal surgical unit in a university teaching hospital.PatientsNeonates who received more than one subsequent dopamine infusion and had invasive arterial blood pressure monitoring, during their admission in the neonatal unit, were included.InterventionsAs part of the Quality Improvement project, the standard operating procedure (SOP) was changed, and dopamine infusions were prepared by nursing staff and left to rest for 30 min before administering to the neonate. Additionally, infusions were replaced every 12 hours.Main outcome measuresThe percentage change in mean arterial pressure (MAP) and the percentage loss in the drug concentration during infusion during changeover.ResultsOur findings indicate that up to 15% of the initial dopamine concentration is lost after 24 hours. This results in a sharp variation in the dopamine concentration during infusion changeover that correlates with observed rapid fluctuations in MAP. In changing the SOP, no significant difference in the concentration of dopamine and MAP were observed over 12 hours.ConclusionsDelaying administration of dopamine infusions by 30 min after preparation combined with changing infusions 12 hourly has reduced MAP fluctuations. Therefore, the risks associated with MAP fluctuations, including intraventricular haemorrhages, are reduced.


2019 ◽  
Vol 15 (6) ◽  
pp. 486-496 ◽  
Author(s):  
Kamran M. Ahmed Aziz

Introduction:In research elevated Blood Pressure (BP) has been demonstrated to be a risk for the development of nephropathy and chronic renal disease (CKD) Or Diabetic Kidney Disease (DKD) among diabetics. However, no study has find correlation for the spot urine protein (UPr) excretion with elevated BP, Pulse Pressure (PP) and mean arterial pressure MAP). This technique was invented in the current study.Methods:10,270 were recruited for more than 12 years. Demographically, 43%, 38%, and 16% showed hypertension, nephropathy and chronic renal disease, respectively. UPr demonstrated significant correlations with systolic BP (SBP) and diastolic BP (DPB), MAP and PP (p < 0.0001 for all). SBP, DBP, PP and MAP, UPr were observed to be higher among the groups with nephroaphty and CKD/DKD with highly significant p-values (all p < 0.05). With logistic regression, odds ratio of hypertension (HTN) with nephropathy was observed to be 2.99 (95% CI 2.44 to 3.7; p < 0.0001); and odds ratio of HTN with CKD/DK was 7.1 (95% CI 4.3 to 11.84; p<0.0001), indicating that HTN significantly contributes to the development of nephropathy and CKD/DKD in diabetics.Results:Invented regression models for the excretion of UPr from the kidney with elevated SBP, DBP, MAP and PP were highly significant (p < 0.0001 for all); UPr = -138.6 + [1.347 × SBP] ; UPr = -93.4 + [1.62 × DBP] ; UPr = -149.5 + [1.922 × MAP] ; UPr = -41.23 +[1.541 × PP].Conclusion:Current study is the first one to introduce this technique. These invented new equations can be used by physicians to estimate protein excretion in urine at bedside and outpatients departments for monitoring proteinuria and CKD/DKD.


2020 ◽  
Vol 8 ◽  
pp. 205031212096233
Author(s):  
Diamanto Aretha ◽  
Panagiotis Kiekkas ◽  
Nektarios Sioulas ◽  
Fotini Fligou

Background: Once a patent expires, generic analogue drugs are alternatives to brand name drugs. Because bioequivalence/biodistribution problems have been reported for many generic analogue drugs, we prospectively evaluated 31 patients to reveal the differences in the doses used and the efficacy and adverse events of two different intravenous esmolol formulations. Methods: This was a prospective observational pilot study. Our aim was to reveal the possible differences in the required doses between two different formulations (brand name drug vs generic analogue drug) of intravenous esmolol in beats per minute, systolic blood pressure, diastolic blood pressure and mean arterial pressure in intra- and postoperative patients with supraventricular tachycardia and hypertension. The patients were categorised into two groups according to the medication they received (brand name drug or generic analogue drug). Results: Esmolol was given to 31 patients (16 generic analogue drug and 15 brand name drug). Although there was a statistically significant difference in bolus (mg/kg) and continued (mg/kg/h) drug dose used (brand name drug/generic analogue drug, mean (standard deviation), 0.3 (0.1) vs 0.38 (0.1), p = 0.03 for bolus dose, and 0.22 (0.09) vs 0.29 (0.08) for continued dose at 10 min (p = 0.03), 0.19 (0.06) vs 0.24 (0.05) at 20 min (p = 0.01) and 0.14 (0.05) vs 0.18 (0.05) at 30 min (p = 0.02)), there were no time-related statistical significant differences in the reduction rates of the two drugs (p = 0.47). There were no time-related statistically significant differences between the two groups in systolic blood pressure, diastolic blood pressure, mean arterial pressure and beats per minute, nor in their adverse events. Conclusion: In this pilot study, smaller doses were given for controlling the patient’s haemodynamics when a brand name drug was used. Because there were no significant time-related differences in the reduction rates of the two drugs nor in any haemodynamic differences between the two groups, optimal titration of the drug used could effectively control the patient’s haemodynamics. The adverse events were also similar in both groups.


Sign in / Sign up

Export Citation Format

Share Document