Abstract Background: The aim of current study was to evaluate and compare the influence of Dycal, Lime-lite, Theracal LC, Biodentine, Resin-modified glass ionomer cement (RMGIC), and Activa Bioactive as the pulp capping material on the shear bond strength of resin composite to dentin.Methods: A total of 70 extracted caries-free molars were randomly assigned to seven groups. Six test groups were covered with various protective liners: Dycal (GD), Theracal LC (GT), lime-lite (GL), Activa Bioactive (GA), Biodentine (GB), RMGIC (GR). The control group (GC)received no liner pretreatment. Each sample was bonded to resin composite using the total-etch tetric N bond adhesive. The samples were then tested for shear bond strength using the universal testing machine at a cross-head speed of 1 mm/min until bond failure occurred. The data were analyzed using the one-way ANOVA test followed by the Tamhane post-hoc test for pairwise comparisons of the groupsResults: Independent of the type of the applied liner, all groups exhibited inferior SBS to dentine compared to the control group. GT and GR showed significantly higher shear bond strength than GB and GD, which showed the lowest shear bond strength. GL and GA also had significantly lower SBS results than GT. The mode of fracture was predominantly cohesive in GD, GB, and GT and adhesive in GA.Conclusion: This present study concludes that the bond strength of resin-composite to dentine can be affected differently using various types of liners.

2021 ◽  
Author(s):  
Ladan Ranjbar Omrani ◽  
Saba Tohidkhah ◽  
Elham Ahmadi ◽  
Mahdi Abbasi ◽  
Reza Morvaridi Farimani

Abstract Background: The aim of the current study was to evaluate and compare the influence of Dycal, Lime-lite, Theracal LC, Biodentine, Resin-modified glass ionomer cement (RMGIC), and Activa Bioactive as the pulp capping material on the shear bond strength of resin composite to dentin.Methods: A total of 70 extracted caries-free molars were randomly assigned to seven groups. Six test groups were covered with various protective liners: Dycal (GD), Theracal LC (GT), lime-lite (GL), Activa Bioactive (GA), Biodentine (GB), RMGIC (GR). The control group (GC)received no liner pretreatment. Each sample was bonded to resin composite using the total-etch tetric N bond adhesive. The samples were then tested for shear bond strength using the universal testing machine at a cross-head speed of 1 mm/min until bond failure occurred. The data were analyzed using the one-way ANOVA test followed by the Tamhane post-hoc test for pairwise comparisons of the groupsResults: Independent of the type of the applied liner, all groups exhibited inferior SBS to dentine compared to the control group. GT and GR showed significantly higher shear bond strength than GB and GD, which showed the lowest shear bond strength. GL and GA also had significantly lower SBS results than GT. The mode of fracture was predominantly cohesive in GD, GB, and GT and adhesive in GA.Conclusion: This present study concludes that the bond strength of resin-composite to dentine can be affected differently using various types of liners.


2021 ◽  
Author(s):  
Ladan Ranjbar Omrani ◽  
Saba Tohidkhah ◽  
Elham Ahmadi ◽  
Mahdi Abbasi ◽  
Reza Morvaridi Farimani

Abstract Background: The aim of the current study was to evaluate and compare the influence of Dycal, Lime-lite, Theracal LC, Biodentine, Resin-modified glass ionomer cement (RMGIC), and Activa Bioactive as the pulp capping material on the shear bond strength of resin composite to dentin.Methods: A total of 70 extracted caries-free molars were randomly assigned to seven groups. Six test groups were covered with various protective liners: Dycal (GD), Theracal LC (GT), lime-lite (GL), Activa Bioactive (GA), Biodentine (GB), RMGIC (GR). The control group (GC)received no liner pretreatment. Each sample was bonded to resin composite using the total-etch tetric N bond adhesive. The samples were then tested for shear bond strength using the universal testing machine at a cross-head speed of 1 mm/min until bond failure occurred. The data were analyzed using the one-way ANOVA test followed by the Tamhane post-hoc test for pairwise comparisons of the groupsResults: Independent of the type of the applied liner, all groups exhibited inferior SBS to dentine compared to the control group. GT and GR showed significantly higher shear bond strength than GB and GD, which showed the lowest shear bond strength. GL and GA also had significantly lower SBS results than GT. The mode of fracture was predominantly cohesive in GD, GB, and GT and adhesive in GA.Conclusion: This present study concludes that the bond strength of resin-composite to dentine can be affected differently using various types of liners.


2021 ◽  
Vol 9 (D) ◽  
pp. 243-247
Author(s):  
Maiada Mohammad Ahmad Sa’ada ◽  
Nagwa Mohammed Ali Khattab ◽  
Maha Ishaq Amer

AIM: The aim of the study was to evaluate effect of silver diamine fluoride (SDF) on the shear bond strength (SBS) of glass ionomer restoration to primary dentine. MATERIALS AND METHODS: Twenty extracted primary molars with no restorations or developmental anomalies were only chosen for the study. Twenty dentine slices with 2 mm thickness were prepared and then randomly allocated into two groups (n = 10 per group). For Group 1 (experimental): Dentine surfaces were treated with 38% *SDF solution (Elevate oral care, USA) for 3 min using micro-brush, followed by a 30 s rinse with water and Group 2 (Control): Dentine surfaces were treated with distilled water for 3 min then rinsed for 30 s. The cavity conditioner was applied to flat dentin of both groups for 10 s then washed and dried gently with compressed air. All the specimens were restored with *RMGIC (Riva Light Cure, SDI, Australia). SBS was determined using a Universal Testing machine and Failure mode was evaluated using stereomicroscope. Data were collected and statistically analyzed. Independent t test was used to assess differences in SBS between study groups and mode of failure was analyzed using Fisher’s exact test. Level of significance was set at p ≤ 0.05. IBM SPSS statistical software (version 26) was used to analyze the data. RESULTS: The experimental group had significantly higher mean of shear bond (11.92 ± 3.35) strength than the control group (6.99 ± 2.98) (p = 0.003). CONCLUSIONS: Primary dentin pre-treatment with 38% SDF increases the shear bond strength between RMGIC and primary dentin according to the results of this in vitro study.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Ahmed Mohammed Hassan ◽  
Ahmed Ali Goda ◽  
Kusai Baroudi

Objective. The aim of this study was to evaluate the effect of different disinfectant agents on bond strength of two types of resin composite materials.Methods. A total of 80 sound posterior teeth were used. They were divided into four groups(n=20)according to the dentin surface pretreatment (no treatment, chlorhexidine gluconate 2%, sodium hypochlorite 4%, and EDTA 19%). Each group was divided into two subgroups according to the type of adhesive (prime and bond 2.1 and Adper easy one). Each subgroup was further divided into two subgroups according to the type of resin composite (TPH spectrum and Tetric EvoCeram). Shear bond strength between dentin and resin composite was measured using Universal Testing Machine. Data collected were statistically analyzed byt-test and one-way ANOVA followed by Tukey’spost hoctest.Results. It was found that dentin treated with EDTA recorded the highest shear bond strength values followed by sodium hypochlorite and then chlorhexidine groups while the control group showed the lowest shear bond strength.Conclusions. The surface treatment of dentin before bonding application has a great effect on shear bond strength between resin composite and dentin surface.


2020 ◽  
Vol 8 (10) ◽  
pp. 454-459
Author(s):  
Bhalla V. ◽  
◽  
K. Goud M. ◽  
Chockattu S. ◽  
Khera A ◽  
...  

Background:Dentin bonding is an ever-evolving field in adhesive dentistry. With the introduction of newer systems into the market, there is a crucial need to test their efficiency in terms of bond strength. Dual-cured adhesives in theory may provide for a better degree of conversion as compared to conventional light-cured adhesives .Thus, the aim of this study was to compare the shear bond strength of three different self-etch adhesives namely ClearfilSE bond (Kuraray), Tetric N Bond Universal (IvoclarVivadent) and Futura Bond DC (Voco) to dentin. Materials & Methods: Ninety extracted non-carious, intact human mandibular molar teeth were selected for this study. Each tooth was decoronated using a double-sided diamond disc with water coolant to a depth of 2mm from the cusp tip .The cut dentin surface was then abraded against 600-grit wet silicon carbide papers for 60 seconds to produce a uniform smear layer. The root portion of each tooth was mounted on a plastic ring using cold cure acrylic resin. Specimens were then divided into three adhesive groups of 30 teeth each, Group A: ClearfilSE Bond (Kuraray), Group B: Tetric N Bond Universal (IvoclarVivadent), Group C :Futura Bond DC (Voco). All bonding agents were used according to the manufacturers’ instructions, in combination with the resin composite Tetric N Ceram (IvoclarVivadent). The samples were thermocycled, followed by shear bond strength testing using a Universal testing machine (Hounsfield). Data were subjected to statistical analysis using one-way analysis of variance (ANOVA) (P<0.05) and Post hoc Tukey’s test for inter- and intra- group analysis respectively. Results: Clearfil SE Bond yielded the highest shear bond strength values (30.9 ±4.66 MPa) which were statistically significant, followed byTetric N Bond Universal group (29.8 ±4.34) and the lowest shear bond strength values were recorded for Futura Bond DC (18.2 ±3.13). Conclusion: Clearfil SE bond and Tetric N bond Universal can be considered as better options than Futura Bond DC.


2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
Andreas Hellak ◽  
Jennifer Ebeling ◽  
Michael Schauseil ◽  
Steffen Stein ◽  
Matthias Roggendorf ◽  
...  

Objective.The aim of this in vitro study was to determine the shear bond strength (SBS) and adhesive remnant index (ARI) score of two self-etching no-mix adhesives (iBond™and Scotchbond™) on different prosthetic surfaces and enamel, in comparison with the commonly used total etch system Transbond XT™.Materials and Methods. A total of 270 surfaces (1 enamel and 8 restorative surfaces,n=30) were randomly divided into three adhesive groups. In group 1 (control) brackets were bonded with Transbond XT primer. In the experimental groups iBond adhesive (group 2) and Scotchbond Universal adhesive (group 3) were used. The SBS was measured using a Zwicki 1120™testing machine. The ARI and SBS were compared statistically using the Kruskal–Wallis test (P≤0.05).Results. Significant differences in SBS and ARI were found between the control group and experimental groups.Conclusions. Transbond XT showed the highest SBS on human enamel. Scotchbond Universal on average provides the best bonding on all other types of surface (metal, composite, and porcelain), with no need for additional primers. It might therefore be helpful for simplifying bonding in orthodontic procedures on restorative materials in patients. If metal brackets have to be bonded to a metal surface, the use of a dual-curing resin is recommended.


Author(s):  
Zahra Khamverdi ◽  
Naemeh Karimian ◽  
Maryam Farhadian ◽  
Hamed Gheitouli

Objectives: Bond strength of composite restorations plays an important role in their success. This in vitro study evaluated the effect of a hemostatic agent on shear bond strength of universal adhesives. Materials and Methods: Thirty-six extracted human molars were used in this study. Buccal and lingual surfaces were reduced to obtain flat dentin surfaces and were ground with a silicone paper. The samples were randomly divided into three groups (n=12) based on the application of hemostatic agent: group 1: no contamination (control), group 2: aluminum chloride application, and group 3: ferric sulfate application. Each group was then divided into two subgroups (n=6) for using G-Premio and Single Bond Universal. Resin cylinders (Filtek Z550) were bonded to dentin surfaces according to the manufacturer’s instructions. After 1000 thermal cycles, shear load was applied to the specimens using a universal testing machine at a crosshead speed of 1 mm/min until failure. Data were statistically analyzed using two-way ANOVA and Tukey’s post-hoc test (α=0.05). Results: There were statistically significant differences in shear bond strength of the three main groups for both G-Premio and Single Bond Universal (P<0.05). When the adhesive systems were compared with each other, G-Premio showed higher shear bond strength than Single Bond Universal (P<0.05). Conclusion: Contamination with hemostatic agents had an adverse effect on the shear bond strength of universal adhesives. Moreover, G-Premio yielded a higher bond strength than Single Bond Universal.


2012 ◽  
Vol 3 (1) ◽  
pp. 41-49
Author(s):  
BM Shivalinga ◽  
H Jyothikiran ◽  
Amit Goyal

ABSTRACT Aims To determine the effect of self-etchant pH on shear bond strength of orthodontic brackets; to compare the shear bond strengths of brackets bonded with three SEPs and brackets bonded with conventional etch, rinse, bond method and to find the brackets/adhesive failure mode. Materials and methods One hundred and twenty premolar teeth were cleaned, mounted, and randomly divided into four groups of 30 samples each- Transbond XT conventional etch and bond system (control), Adper SE Plus SEP (3M ESPE) with a pH of 0.9 to 1.0, Transbond Plus SEP (3M Unitek) with a pH of about 1.0 and Clearfil SE Bond SEP (Kuraray America) with a pH of around 2.0. All teeth were bonded with Transbond XT paste (3M Unitek). The teeth were debonded within half an hour after initial bonding by using a universal testing machine. The residual adhesive on each tooth was evaluated. ANOVA was used to compare the shear bond strength (SBS) of the three groups, and the Chi-square test was used to compare the adhesive remnant index (ARI) scores for the three groups. Results ANOVA indicated significant differences between the groups. Clearfil attained the SBS (6.5 ± 0.6689 MPa) closest to the control group, whereas Adper inspite of being the most aggressive recorded the lowest SBS (5.7 ± 0.5695 MPa). Transbond self-etching primer achieved a mean SBS of 6.1 ± 0.6211 MPa. However, all the three SEPs recorded SBS which was significantly less than that of Transbond conventional etch, rinse and bond system (11.8027 ± 0.8059 MPa). The comparisons of the ARI scores between the three groups indicated that bracket failure mode was significantly different between the three groups (p < 0.05). Conclusion These findings show that factors other than pH, such as the ability of the bonding adhesive to form a chemical bond to enamel and the strength of the bonding adhesive itself, significantly influence the SBS of orthodontic brackets. How to cite this article Goyal A, Jyothikiran H, Shivalinga BM. Effect of Self-etchant pH on Shear Bond Strength of Orthodontic Brackets: An in vitro Study. World J Dent 2012;3(1):41-49.


2018 ◽  
Vol 7 (2) ◽  
pp. 28-31
Author(s):  
Varunjeet Chaudhary ◽  
Sanad Singh Solanki ◽  
Varsha Yadav ◽  
Seema Lahoti

Objective: To evaluate the shear bond strength of stainless steel brackets bonded with fluoride-releasing composite resins, comparing effect of adhesion booster and conventional primer.Materials & Method: Sixty extracted premolars were subjected to bracket bonding with fluoride-releasing composite resin; which were bonded by randomly divided into two groups of bonding agents: Group 1- conventional primer as control group, Group 2- adhesion booster. After bonding, the samples were thermocycled (500 cycles) at 5ºC and 55ºC temperatures. After 48 hours they were subjected to shear bond strength testing in occluso-gingival direction, using an MTS 810 Universal Testing Machine with load speed of 0.5 mm/min.Result: Mean shear bond strength was significantly more in samples bonded with adhesion booster (14.792±3.805 Mpa) as compared to conventional primers (11.327±4.047 Mpa). There was statistically significant difference in shear bond strength between the groups (p=0.001).Conclusion: The use of the adhesion booster significantly increased the bond strength of bracket bonded with fluoride-releasing composite.