Exceeding the electric field’s limit value is not allowed in the vicinity of high-voltage power lines because of both legal and safety aspects. The design parameters of the line must be chosen so that such cases do not occur. However, analysis of several operating power lines in Europe found that the electric field strength in many cases exceeds the legally prescribed limit for the general public. To illustrate this issue and its importance, field measurement and finite element simulation results of the low-frequency electric field are presented for an active 400 kV power line. The purpose of this paper is to offer a new, economical expert system based on dynamic line rating (DLR) that utilizes the potential of real-time power line monitoring methods. The article describes the expert system’s strengths and benefits from both technical and financial points of view, highlighting DLR’s potential for application. With our proposed expert system, it is possible to increase a power line’s safety and security by ensuring that the electric field does not exceed its limit value. In this way, the authors demonstrate that DLR has other potential applications in addition to its capacity-increasing effect in the high voltage grid.


2013 ◽  
Vol 158 (2) ◽  
pp. 221-223 ◽  
Author(s):  
L. Korpinen ◽  
H. Kuisti ◽  
H. Tarao ◽  
R. Paakkonen ◽  
J. Elovaara

2021 ◽  
Vol 25 (2) ◽  
pp. 28-33
Author(s):  
N.A. Litvinova ◽  
I.S. Kyrie

The results of studies of the practice of use in the construction of residential facilities located next to power lines, mesh metal materials, which have the shielding ability On the example of mesh metal materials (iron, aluminum, copper) used as a shielding material together with the roof of a building and in external walls, indicators reflecting the effectiveness of electromagnetic shielding are obtained. Also, according to the results of the study, it was found that when shielding an electric field of industrial frequency, it is important to take into account not only the material from which the screen is made, but also its.


2014 ◽  
Vol 50 (17) ◽  
pp. 1236-1238 ◽  
Author(s):  
Hoseong Kim ◽  
Dongkil Choi ◽  
Sungmin Gong ◽  
Kyungjin Park

2019 ◽  
Vol 139 ◽  
pp. 01042
Author(s):  
Mixail Obalin ◽  
Georgij Majstrenko

The influence of voltage characteristics deviations, acceptable in normal operation of power grid, at power lines emergency state fault location methods precision is considered. The error distributions of emergency state fault location methods across power line length under frequency deviation, single rapid voltage changing and supply voltage unbalance variation are received. The way of emergency state fault location adaptation to voltage characteristics deviations is offered.