scholarly journals Forming DMAs in a water distribution network considering the operating pressure and the chlorine residual concentration as the design parameters

2017 ◽  
Vol 19 (6) ◽  
pp. 900-910 ◽  
Author(s):  
Konstantinos Gonelas ◽  
Apostolos Chondronasios ◽  
Vasilis Kanakoudis ◽  
Menelaos Patelis ◽  
Panagiota Korkana

Abstract Dividing a water distribution network (WDN) in the optimal district metered areas (DMAs) formation is one task that usually troubles water utility managers. The present paper utilizes optimization methods to achieve desired segmentation conditions in terms of (a) operating pressure reduction, thus reducing the system's real water losses and (b) residual chlorine concentration reduction thus preventing disinfection byproducts' growth. Exploiting the numerous possibilities offered by the inter-connection of Matlab and EPANET software tools, an algorithm is developed in C++ language. The algorithm reads all significant data of a WDN as an output of EPANET. The first algorithm calculates the optimal allocation of a given number of closed isolation valves in terms of water losses' reduction, considering restrictions for network's proper operation. The second algorithm calculates the optimal formation of DMAs in terms of water quality improvement. Both algorithms can be applied in any WDN. The outcome is the optimal set of closed pipes that leads to the optimal formation of DMAs in a given network. The closing of pipes (by installing isolation valves) determines the optimal formation of DMAs. The basic concept of both algorithms and their application in a case study network's hydraulic model are presented.

2008 ◽  
Vol 3 (2) ◽  
Author(s):  
Jayong Koo ◽  
Toyono Inakazu ◽  
Akira Koizumi ◽  
Yasuhiro Arai ◽  
Kyoungpil Kim ◽  
...  

It is difficult to estimate residual chlorine at the dead-end area of the water distribution network because chlorine consumption is influenced by various factors. Therefore, there are many water utilities that control the amounts of chlorine in reservoirs using empirical trial-and-error methods to maintain safe levels of residual chlorine in the distribution system. In this study, an ANN model of residual chlorine concentration is proposed which could be used to reduce in chlorine use in water distribution system. The ANN model with best performance was selected by training and verification. The five scenarios for the reduction in chlorine use were analyzed by setting the input chlorine as low as 0.05~0.25 mg/L compared with the input chlorine observed in the time series. Case 4 is the best to be satisfied with the input condition (0.4 mg/L or more) and output condition (0.34 mg/L or more) at the same time. It is possible to reduce chlorine in use up to 0.2 mg/L in the maximum amount.


2020 ◽  
Vol 2 (1) ◽  
pp. 51
Author(s):  
Nikolaos Kourbasis ◽  
Menelaos Patelis ◽  
Stavroula Tsitsifli ◽  
Vasilis Kanakoudis

Water distribution networks suffer from high levels of water losses due to leaks and breaks, mainly due to high operating pressure. One of the most well-known methods to reduce water losses is pressure management. However, when the operating pressure in a water distribution network reduces, the time the water stays within the network (called water age) increases. Increased water age means deteriorated water quality. In this paper, water pressure in relation to water age is addressed in a water distribution network in Greece. Using simulation and optimization tools, the optimum solution is found to reduce water age and operating pressure at the same time. In addition, District Metered Areas are formed and water age is optimized.


Author(s):  
Ahmed Al Naamani ◽  
Ahmad Sana

Abstract A water distribution network in an urban area in Muscat region (capital city of Oman) is assessed for operational performance using the widely accepted methodology proposed by International Water Association (IWA). The technical performance of this network was assessed using global performance index methods after modifying the performance levels as per local guidelines. A total of 37 operational performance indicators for the network were selected to carryout assessment. Overall operational performance showed high scores whereas some indicators showed unacceptable performance values. The network showed very high technical performance considering nodal pressures. The lower performance for pipe velocity may be attributed to the fact that the network is currently being utilized by 70% of the population for which it was designed. The residual chlorine levels were within the acceptable range of the Public Authority for Water (PAW) showing a very good performance by virtue of water quality. This study will be useful for the decision makers to assess the operational, technical and water quality performance of urban networks and take actions for improvements.


Proceedings ◽  
2018 ◽  
Vol 2 (11) ◽  
pp. 593
Author(s):  
Sorin Perju ◽  
Alexandru Aldea

This paper presents the results recorded by upgrading and rehabilitating the pumping stations for an urban water network with a primary goal of diminishing the operation and maintenance costs and a secondary goal of reducing the water losses in the water distribution network. The adopted technical solutions within the structural and functional modifications of the pumping stations have led to both the improvement of hydraulic parameters of the pumping stations and also the improvement of registered energy consumption. The undertaken modifications and transformations within the pumping stations led to significant energy savings and at the same time to important water losses reductions within the distribution network.


2009 ◽  
Vol 9 (2) ◽  
pp. 141-147 ◽  
Author(s):  
Mukand S. Babel ◽  
Md. S. Islam ◽  
A. Das Gupta

Losses of water due to leakage occur in every distribution network, the only difference is in the amount of leakage. The leakage levels are relatively high in cities of developing Asian countries. Among the several factors, operating pressure is the most important affecting the leakage. This paper describes how the management of pressure can help reduce the leakage in the water distribution network. EPANET is used to develop the hydraulic model to analyse the effect of alternative pressure profiles on the leakage in a pilot area within the water distribution system of Bangkok. One of the alternatives is implemented in the field to verify the applicability of the model. Results indicate that the average reduction in pressure by 2.4 m can reduce the leakage by 12.5% of the system inflow without compromising the level of service.


The current study was carried out to analyze the residual chlorine decay analysis within the existing Juja water distribution network. The study used EPANET as a simulation tool. From the field samples, the first-order bulk decay coefficient Kb was found equal to - 0.04 . The wall coefficient Kw was assumed to - 4.0 mg/ /day as guided by literature. The analysis shows that the entire supply area of the existing distribution network faces higher residual chlorine concentration (0.70 to 0.8 mg/l) from 9 am. The study recommended the reducing of the initial chlorine added at the treatment plant and the optimization of the network, which will provide a proper residual chlorine dosage to reduce Juja consumers exposure to health risk and also to be economically reasonable for the water company in charge


2011 ◽  
Vol 13 (3) ◽  
pp. 390-400 ◽  
Author(s):  
Kui Chang ◽  
Jin Liang Gao ◽  
Wen Yan Wu ◽  
Yi Xing Yuan

In order to evaluate water quality for a large water distribution network comprehensively, a two-stage classification method was used and the clustering methods, self-organizing map (SOM), K-means method and fuzzy c-mean (FCM), were represented. With these clustering methods, the pipes of a large real water distribution network were divided into some groups considering one or more water quality indicators synchronously. The water quality indicators of residual chlorine, water age, THMs, TAAs, TOC and BDOC are used in this paper. Residual chlorine and water age are two main water quality indicators. THMs and TAAs can represents the disinfection byproducts information. And TOC and BDOC are used to represents biological stability. According to the clustering results, the status of water quality of the water network was analysed. The results showed that the classification of SOM could express the comprehensive water quality in a water distribution network (WDN) directly and vividly by high-dimension water quality indicator projection to a low dimensional topology grid and that two-stage classification method has higher efficiency in comparison to the traditional clustering method. Water quality comprehensive evaluation was of significance for locating water quality monitoring, water network rehabilitation and expansion.


Sign in / Sign up

Export Citation Format

Share Document