Leakage management in a low-pressure water distribution network of Bangkok

2009 ◽  
Vol 9 (2) ◽  
pp. 141-147 ◽  
Author(s):  
Mukand S. Babel ◽  
Md. S. Islam ◽  
A. Das Gupta

Losses of water due to leakage occur in every distribution network, the only difference is in the amount of leakage. The leakage levels are relatively high in cities of developing Asian countries. Among the several factors, operating pressure is the most important affecting the leakage. This paper describes how the management of pressure can help reduce the leakage in the water distribution network. EPANET is used to develop the hydraulic model to analyse the effect of alternative pressure profiles on the leakage in a pilot area within the water distribution system of Bangkok. One of the alternatives is implemented in the field to verify the applicability of the model. Results indicate that the average reduction in pressure by 2.4 m can reduce the leakage by 12.5% of the system inflow without compromising the level of service.

2008 ◽  
Vol 3 (2) ◽  
Author(s):  
Jayong Koo ◽  
Toyono Inakazu ◽  
Akira Koizumi ◽  
Yasuhiro Arai ◽  
Kyoungpil Kim ◽  
...  

It is difficult to estimate residual chlorine at the dead-end area of the water distribution network because chlorine consumption is influenced by various factors. Therefore, there are many water utilities that control the amounts of chlorine in reservoirs using empirical trial-and-error methods to maintain safe levels of residual chlorine in the distribution system. In this study, an ANN model of residual chlorine concentration is proposed which could be used to reduce in chlorine use in water distribution system. The ANN model with best performance was selected by training and verification. The five scenarios for the reduction in chlorine use were analyzed by setting the input chlorine as low as 0.05~0.25 mg/L compared with the input chlorine observed in the time series. Case 4 is the best to be satisfied with the input condition (0.4 mg/L or more) and output condition (0.34 mg/L or more) at the same time. It is possible to reduce chlorine in use up to 0.2 mg/L in the maximum amount.


2011 ◽  
Vol 14 (1) ◽  
pp. 65-74 ◽  
Author(s):  
M. Ferrante ◽  
E. Todini ◽  
C. Massari ◽  
B. Brunone ◽  
S. Meniconi

In water distribution network simulation models, pipes subject to diffuse outflow, either due to connections or to distributed demand or to leaks along their length, are generally converted into pipe elements only subject to lumped demand at their ending nodes. This approximation, which disregards the flow variation along the pipes, generates a loss of axial momentum, which is not correctly taken into account in the present generation of water distribution network models. In this paper a correction to the lumped demand approximation is provided and this equivalence is analyzed within the framework of the Global Gradient Algorithm. This is obtained through a correction of the pipe hydraulic resistance; this approach has proven to be more effective than the use of an asymmetrical lumped demand of the total distributed outflow at the pipe ending nodes. In order to assess the effect of the introduced correction, an application to a simple water distribution system is finally provided.


Author(s):  
Lakshmi Kanthan Narayanan ◽  
Suresh Sankaranarayanan ◽  
Joel J P C Rodrigues ◽  
Sergei Kozlov

Most of the water losses occur during water distribution in pipelines during transportation. In order to eradicate the losses, an “IoT based water distribution system” integrated with “Fog and Cloud Computing" proposed for water distribution and underground health monitoring of pipes. For developing an effective water distribution system based on Internet of Things (IoT), the demand of the consumer should be analysed. So, towards predicting the water demand for consumers, Deep learning methodology called Long Short-Term Memory (LSTM) is compared with traditional Time Series methodology called Auto Regressive Integrated Moving Average (ARIMA) in terms of error and accuracy. Now based on demand prediction with higher accuracy, an IoT integrated “Water Distribution Network (WDN)” is designed using hydraulic engineering. This WDN design will ensure minimal losses during transportation and quality of water to the consumers. This will lead to development of a smart system for water distribution.


2008 ◽  
Vol 8 (4) ◽  
pp. 421-426
Author(s):  
J. Menaia ◽  
M. Benoliel ◽  
A. Lopes ◽  
C. Neto ◽  
E. Ferreira ◽  
...  

Concerns arise from the possible occurrence of pathogens in drinking water pipe biofilms and storage tank sediments. In these studies, biofilm samples from pipes and sediments from storage tanks of the Lisbon drinking water distribution system were analyzed. Protein determinations and heterotrophic counts on pipe biofilm samples were used to assess the Lisbon network sessile colonization intensity and distribution. Indicator and pathogenic microorganisms were analyzed in pipe biofilm samples, as well as in storage tanks biofilm and sediments, by using cultural methods and PCR, to assess risks. Results have shown that the Lisbon network sessile colonization is relatively weak in intensity. In addition, no meaningful hazards were apparent for both the network biofilm and the storage tanks biofilm and sediments.


2010 ◽  
Vol 10 (2) ◽  
pp. 165-172 ◽  
Author(s):  
K. Diao ◽  
M. Barjenbruch ◽  
U. Bracklow

This paper aims to explore the impacts of peaking factors on a water distribution system designed for a small city in Germany through model-based analysis. As a case study, the water distribution network was modelled by EPANET and then two specific studies were carried out. The first study tested corresponding system-wide influences on water age and energy consumption if the peaking factors used at design stage are inconsistent with ones in real situation. The second study inspected the possible relationship between the choice of peaking factors and budgets by comparing several different pipe configurations of the distribution system, obtained according to variety of peaking factors. Given the analysis results, the first study reveals that average water age will increase if peaking factors estimated at design stage are larger than real values in that specific system, and vice versa. In contrast, energy consumption will increase if peaking factors defined for system design are smaller than ones in real case, and vice versa. According to the second study, it might be possible to amplify peaking factors for design dramatically by a slight increase in the investment on this system. However, further study on budget estimation with more factors and detailed information considered should be carried out.


2009 ◽  
Vol 9 (1) ◽  
pp. 67-74 ◽  
Author(s):  
Elise Corbi ◽  
Valérie Jacquemet ◽  
Alain Quendo ◽  
Francine Manciot ◽  
Adeline Lamy ◽  
...  

Lyon, France has the opportunity to distribute in abundance a groundwater resource with a good quality for drinking water. However, the length and the complexity of the distribution network can lead to consumer complaints in some areas of the water distribution system. In order to improve the organoleptic quality of distributed water, the water supplier wants to get a better understanding of potential taste and odour formation and to succeed in controlling it. Since 2006, activities have been taken with targeted analyses and sensory evaluation of water, taking into account both the consumers' private networks and the citywide distribution network. The first results were focused on the occurrence of bromophenols along the water distribution system, the understanding of the mechanisms of formation of such compounds, as well as their incidence on taste-and-odour events at the consumer's home.


2019 ◽  
Vol 3 (2) ◽  
pp. 172
Author(s):  
Ayu Rahmad Jayanti ◽  
Ririn Endah Badriani ◽  
Yeny Dhokhikah

The clean water distribution in the Genteng Subdistrict, Banyuwangi Regency is included in the service area of the Zone 1 PDAM tile unit. The 60 liters/second reservoir discharge capacity is obtained from Sumber Umbul Sari in the Glenmore District. The distribution of clean water in Zone 1 is still less than 70% of the area served, as the installed discharge capacity is estimated to be insufficient. In order to achieve the distribution goal, a network system must be developed by adding direct debits and planning a new pipeline. The Epanet 2.0 program simplifies the calculation of pipeline networks by integrating elevation data, network maps, pipeline specification, and load. The analysis of the simulation results was conducted using the Public Works Minister's hydraulic parameter standards 2007. Planning of a distribution network and a cost budget in 2029 were done to estimate the water supply needs and budgets required. The hydraulic simulation results based on the analysis of the pressure of all joints are in accordance with the standard, while the analysis of the velocity in pipe is less standard. The need for water discharge in 2029 is 71.6 liters/second. In Kembiritan Village, the construction of distribution pipes with an additional reservoir unit was planned. The planned pipe dimensions in the development area were 25 mm at 796 meters, 50 mm at 4062 meters, and 75 mm at 1518 meters. The cost of planning a clean water distribution system in 2029 is Rp. 1,431,375,000.00. Distribusi air bersih di Kecamatan Genteng Kabupaten Banyuwangi merupakan wilayah pelayanan Zona 1 PDAM unit Genteng. Kapasitas debit reservoir sebesar 60 liter/detik berasal dari sumber umbul sari di Kecamatan Glenmore. Pendistribusian air bersih di wilayah Zona 1 masih kurang dari 70% wilayah yang terlayani, karena diperkirakan kapasitas debit yang terpasang kurang mencukupi. Untuk memenuhi target pemerataan distribusi perlu pengembangan sistem jaringan dengan penambahan debit dan perencanaan jaringan pipa baru. Program Epanet 2.0 memudahkan dalam perhitungan jaringan perpipaan dengan mengintegrasi data elevasi, peta jaringan, spesifikasi pipa dan debit. Analisis hasil simulasi menggunakan standar parameter hidrolis Permen PU 2007. Perencanaan pengembangan jaringan distribusi dan anggaran biaya pada tahun 2029 guna memperkirakan debit kebutuhan air dan anggaran biaya yang dibutuhkan. Hasil simulasi hidrolis berdasarkan analisis tekanan semua junction telah sesuai standar, sedangkan analisis kecepatan masih di bawah standar. Kebutuhan debit air tahun 2029 sebesar 71,6 Liter/detik. Pengembangan pipa distribusi direncanakan di Desa Kembiritan dengan tambahan satu unit reservoir. Dimensi pipa rencana di wilayah pengembangan digunakan diameter 25 mm sepanjang 796 m, diameter 50 mm sepanjang 4062 m dan diameter 75 mm sepanjang 1518 m. Biaya perencanaan sistem distribusi air bersih tahun 2029 sebesar Rp. 1.431.375.000,00.


2019 ◽  
Vol 22 (4) ◽  
pp. 681-690 ◽  
Author(s):  
A. Fiorini Morosini ◽  
O. Caruso ◽  
P. Veltri

Abstract The current paper reports on a case study investigating water distribution system management in emergency conditions when it is necessary to seal off a zone with isolation valves to allow repair. In these conditions, the pressure-driven analysis (PDA) is considered to be the most efficient approach for the analysis of a water distribution network (WDN), as it takes into account whether the head in a node is adequate to ensure service. The topics of this paper are innovative because, until now, previous approaches were based on the analysis of the network behaviour in normal conditions. In emergency conditions, it is possible to measure the reliable functioning of the system by defining an objective function (OF) that helps to choose the optimal number of additional valves in order to obtain adequate system control. The OF takes into account the new network topology by excluding the zone where the broken pipe is located. The results show that the solution did not improve significantly when the number of valves reached a threshold. The procedure applied to other real case studies seems to confirm the efficiency of the methodology even if further examination of other cases in different conditions is necessary.


2020 ◽  
Vol 20 (8) ◽  
pp. 2964-2970
Author(s):  
D. P. Ayadi ◽  
A. Rai ◽  
A. Pandey

Abstract The effective and efficient supply of drinking water resources are key to its long-term use and access. In recent decades, the population of Kathmandu Valley has exploded owing to several factors. The water supply system here has also undergone remarkable changes and efforts have been made to enhance its equitable distribution. The major effort, of course, is the Melamchi Water Supply Project (MWSP). As the project approaches completion of its first phase, we would like to point out several key issues for the water distribution system here and express our opinions on promoting equitable water distribution. For this we conducted a thorough literature review and found that improvement in the water distribution network and water tariff in the valley, along with promotion of alternative mitigation options, are the focal issues for promoting an equitable water distribution system in Kathmandu Valley.


2013 ◽  
Vol 15 (3) ◽  
pp. 862-880 ◽  
Author(s):  
M. Ehsan Shafiee ◽  
Emily M. Zechman

In the event that a contaminant is introduced to a water distribution network, a large population of consumers may risk exposure. Selecting mitigation actions to protect public health may be difficult, as contamination is a poorly predictable dynamic event. Consumers who become aware of an event may select protective actions to change their water demands from typical demand patterns, and new hydraulic conditions can arise that differ from conditions that would be predicted when demands are considered as exogenous inputs. Consequently, the movement of the contaminant plume in the pipe network may shift from its expected trajectory. A sociotechnical model is developed here to integrate agent-based models of consumers with an engineering water distribution system model and capture the dynamics between consumer behaviors and the water distribution system for predicting contaminant transport and public exposure. Consumers are simulated as agents with behaviors, including movement, water consumption, exposure, reduction in demands, and communication with other agents. As consumers decrease their water use, the location of the contaminant plume is updated and the amount of contaminant consumed by each agent is calculated. The framework is tested through simulating realistic contamination scenarios for a virtual city and water distribution system.