scholarly journals OPTIMIZATION OF TECHNOLOGICAL SCHEME OF A SMALL BIOLOGICAL TREATMENT PLANT

2021 ◽  
Author(s):  
Alexandru Visnevschi ◽  
1994 ◽  
Vol 30 (5) ◽  
pp. 87-95 ◽  
Author(s):  
Susan E. Murcott ◽  
Donald R. F. Harleman

In the past decade, the development of polymers and new chemical technologies has opened the way to using low doses of chemicals in wastewater treatment. “Chemical upgrading” (CU) is defined in this paper as an application of these chemical technologies to upgrade overloaded treatment systems (typically consisting of conventional primary plus biological treatment) in Central and Eastern European (CEE) countries. Although some of the chemical treatment technologies are proven ones in North America, Scandinavia, and Germany, a host of factors, for example, the variations in composition and degree of pollution, the type of technologies in use, the type and mix of industrial and domestic sewage, and the amount of surface water, had meant that the viability of using CU in CEE countries was unknown. This report describes the first jar tests of CU conducted during the summer of 1993. The experiments show CU's ability to improve wastewater treatment plant performance and to potentially assist in the significant problem of overloaded treatment plants. Increased removal of BOD, TSS, and P in the primary stage of treatment is obtained at overflow rates above 1.5 m/h, using reasonably priced, local sources of metal salts in concentrations of 25 to 50 mg/l without polymers.


1995 ◽  
Vol 32 (9-10) ◽  
pp. 75-84 ◽  
Author(s):  
A. D. Andreadakis ◽  
G. H. Kristensen ◽  
A. Papadopoulos ◽  
C. Oikonomopoulos

The wastewater from the city of Thessaloniki is discharged without treatment to the nearby inner part of the Thessaloniki Gulf. The existing, since 1989, treatment plant offers only primary treatment and did not operate since the expected effluent quality is not suitable for safe disposal to the available recipients. Upgrading of the plant for advanced biological treatment, including seasonal nitrogen removal, is due from 1995. In the mean time, after minor modifications completed in February 1992, the existing plant was put into operation as a two-stage chemical-biological treatment plant for 40 000 m3 d−1, which corresponds to about 35% of the total sewage flow. The operational results obtained during the two years operation period are presented and evaluated. All sewage and sludge treatment units of the plant perform better than expected, with the exception of the poor sludge settling characteristics, due to severe and persistent bulking caused by excessive growth of filamentous microorganisms, particularly M. Parvicella. Effective control of the bulking problem could lead to more cost-effective operation and increased influent flows.


2008 ◽  
Vol 57 (8) ◽  
pp. 1287-1293 ◽  
Author(s):  
A. Jobbágy ◽  
G. M. Tardy ◽  
Gy. Palkó ◽  
A. Benáková ◽  
O. Krhutková ◽  
...  

The purpose of the experiments was to increase the rate of activated sludge denitrification in the combined biological treatment system of the Southpest Wastewater Treatment Plant in order to gain savings in cost and energy and improve process efficiency. Initial profile measurements revealed excess denitrification capacity of the preclarified wastewater. As a consequence, flow of nitrification filter effluent recirculated to the anoxic activated sludge basins was increased from 23,000 m3 d−1 to 42,288 m3 d−1 at an average preclarified influent flow of 64,843 m3 d−1, Both simulation studies and microbiological investigations suggested that activated sludge nitrification, achieved despite the low SRT (2–3 days), was initiated by the backseeding from the nitrification filters and facilitated by the decreased oxygen demand of the influent organics used for denitrification. With the improved activated sludge denitrification, methanol demand could be decreased to about half of the initial value. With the increased efficiency of the activated sludge pre-denitrification, plant effluent COD levels decreased from 40–70 mg l−1 to < 30–45 mg l−1 due to the decreased likelihood of methanol overdosing in the denitrification filter


2011 ◽  
Author(s):  
Janet M. Blatny ◽  
Jaran S. Olsen ◽  
Øyvind Andreassen ◽  
Viggo Waagen ◽  
Bjørn Anders P. Reif

2015 ◽  
Vol 16 (2) ◽  
pp. 3769-3782 ◽  
Author(s):  
Carlos Alvarez-Gallego ◽  
Luis Fdez-Güelfo ◽  
María de los Angeles Romero Aguilar ◽  
Luis Romero García

1992 ◽  
Vol 25 (1) ◽  
pp. 45-51 ◽  
Author(s):  
Larbi Tebai ◽  
Ioannis Hadjivassilis

Soft drinks industry wastewater from various production lines is discharged into the Industrial Effluent Treatment Plant. The traditional coagulation/flocculation method as first step, followed by biological treatment as second step, has been adopted for treating the soft drinks industry wastewaters. The performance of the plant has been evaluated. It has been found that the effluent characteristics are in most cases in correspondence with the requested standards for discharging the effluent into the Nicosia central sewerage system.


Sign in / Sign up

Export Citation Format

Share Document