scholarly journals High Temperature Fluoride Salt Test Loop

2015 ◽  
Author(s):  
Adam M. Aaron ◽  
Richard Burns Cunningham ◽  
David L. Fugate ◽  
David Eugene Holcomb ◽  
Roger A. Kisner ◽  
...  
Author(s):  
Chenglong Wang ◽  
Yao Xiao ◽  
Jianjun Zhou ◽  
Dalin Zhang ◽  
Suizheng Qiu ◽  
...  

The Fluoride-salt-cooled High temperature Reactor (FHR) is new reactor concept-about a decade old which is mainly on going in China and U.S. The preliminary thermal-hydraulic studies of the Fluoride salt cooled High temperature Test Reactor (FHTR) is necessary for the development of the FHR technology. In this paper, the thermal-hydraulics of FHTR (also called TMSR-SF) designed by Shanghai Instituted of Applied Physics (SINAP) is studied in different power modes. The temperature distributions of the coolant and the fuel pebble are obtained using a steady-state thermal-hydraulic analysis code for FHR. The comprehensive local flow and heat transfer are investigated by computational fluid dynamics (CFD) for the locations where may have the maximum pebble temperature based on the results from single channel analysis. The profiles of temperature, velocity, pressure and Nu of the coolant on the surface of the pebble as well as the temperature distribution of a fuel pebble are obtained and analyzed. Numerical results showed that the results of 3-D simulation are in reasonable agreement with that of single channel model and also illustrated safety operation of the preliminary designed TMSR-SF in different power mode.


Author(s):  
Xiangbo Kong ◽  
Yuan Fu ◽  
Jianyu Zhang ◽  
Huiju Lu ◽  
Naxiu Wang

A FLiNaK high temperature test loop, which was designed to support the Thorium Molten Salt Reactor (TMSR) program, was constructed in 2012 and is the largest engineering-scale fluoride loop in the world. The loop is built of Hastelloy C276 and is capable of operating at the flow rate up to 25m3/h and at the temperature up to 650°C. It consists of an overhung impeller sump-type centrifugal pump, an electric heater, a heat exchanger, a freeze valve and a mechanical one, a storage tank, etc. Salt purification was conducted in batch mode before it was transferred to and then stored in the storage tank. The facility was upgraded in three ways last year, with aims of testing a 30kW electric heater and supporting the heat transfer experiment in heat exchanger. Firstly, an original 100kW electric heater was replaced with a 335kW one to compensate the overlarge heat loss in the radiator. A pressure transmitter was subsequently installed in the inlet pipe of this updated heater. Finally, a new 30kW electric heater was installed between the pump and radiator, the purpose of which was to verify the core’s convective heat transfer behavior of a simulator design of TMSR. Immediately after these above works, shakedown test of the loop was carried out step by step. At first the storage tank was gradually preheated to 500°C so as to melt the frozen salt. Afterwards, in order to make the operation of transferring salt from storage tank to loop achievable, the loop system was also preheated to a relatively higher temperature 530°C. Since the nickel-base alloy can be severely corroded by the FLiNaK salt once the moisture and oxygen concentration is high, vacuum pumping and argon purging of the entire system were alternatively performed throughout the preheating process, with the effect of controlling them to be lower than 100ppm. Once the salt was transferred into the loop, the pump was immediately put into service. At the very beginning of operation process, it was found that flow rate in the main piping could not be precisely measured by the ultrasonic flow meter. Ten days later, the pump’s dry running gas seal was out of order. As a result, the loop had to be closed down to resolve these issues.


2015 ◽  
Author(s):  
Charles Forsberg ◽  
Lin-wen Hu ◽  
Per Peterson ◽  
Kumar Sridharan

Author(s):  
Junya Nakata ◽  
Mikihiro Wakui ◽  
Michitsugu Mori ◽  
Hiroto Sakashita ◽  
Charles Forsberg

The Fluoride-salt-cooled High-temperature Reactor (FHR) is a new concept of nuclear power reactor being investigated mainly in U.S. and China. The coolant is a liquid salt with a melting point of about 460°C and a boiling point of over 1400°C. As the baseline decay heat removal system, a passive Direct Reactor Air Cooling System (DRACS) is utilized. Though DRACS system has been developed in Sodium Fast reactors (SFR), there are some differences between both. For example, the system in FHR must decrease heat removal when temperatures are low to avoid freezing of the salt and blocking the flow of liquid. Therefore, considering its characteristics, a numerical investigation of DRACS system is needed to evaluate whether FHR has proper ability to remove decay heat and to be robust for a long-time cooling operation after even a severe accident. Furthermore, in addition to its performance evaluation, it is required to make up the operation plan of FHR considering features of this system. It is highly important, with the view of avoiding severe accident, to determine by when the system should be started up. In both countries mentioned above, Fluoride-salt-cooled High-temperature Test Reactor (FHTR) is currently in progress to build. Reviewing its design and system is a crucial step needed to develop the FHR technology. In this research, a performance of DRACS system under some thermal-hydraulic basic events was evaluated by numerical simulation. This paper also suggested the adequate operation procedure suitable for FHTR to avoid a severe accident.


Sign in / Sign up

Export Citation Format

Share Document