Study on Selective Leakage Protection System of Mine High Voltage Grid Based on Harmonic Phase Comparison

2015 ◽  
Vol 9 (1) ◽  
pp. 253-262
Author(s):  
Liu Zhongfu ◽  
Zhang Junxing ◽  
Shi Lixin ◽  
Yang Yaning

As for the wide application of arc suppression coil to the grounding in neutral point of mine high voltage grid, grid leakage fault rules and harmonic characteristics of the neutral point grounding system through arc suppression coil are analyzed, the selective leakage protection program “zero-sequence voltage starts, fifth harmonics of grid zerosequence voltage and zero-sequence current are extracted for phase comparison” is proposed, and corresponding fifth harmonic extraction circuit and power direction discrimination circuit are designed. The experimental results show that the protective principle applies not only to the neutral point insulated power supply system, but also to the power supply system in which neutral point passes arc suppression coil, which can solve selective leakage protection problems under different neutral grounding ways, improving the reliability of selective leakage and guaranteeing the stability of the action value.

2013 ◽  
Vol 846-847 ◽  
pp. 190-194
Author(s):  
Shu Jun Yin ◽  
Xue Ren Li ◽  
Ji Geng Luo

The paper designs a three-phase high voltage power supply system based on active disturbance rejection controller which make single-chip microcomputer ATmega128 as the main control chip and the system improve the stability and control precision of dust removing power. Engineering practice shows that, the DC power supply system has the advantages of convenient operation, high work efficiency, system stability.


2019 ◽  
Vol 78 (1) ◽  
pp. 10-18 ◽  
Author(s):  
Yu. I. Zharkov ◽  
N. A. Popova ◽  
E. P. Figurnov

When calculating short-circuit currents in the AC traction network, it is assumed that each of the traction substations receives power from uncoupled external power supply sources with known resistances. In some cases, especially when powering a group of traction substations from a high-voltage power line of a longitudinal power supply, the external power supply system affects not only the magnitude of short-circuit currents, but also their redistribution between adjacent traction substations of the interstation area where this circuit is considered. Such unrecorded redistribution can have a negative effect on short circuit protection. The article considers the equivalent circuit of the traction network, taking into account resistance of the external power supply system. Particular attention is paid to the fact that in replacement circuits of direct and negative sequence value of reduced resistance of one phase of a multiwinding transformer, calculated from the short circuit voltage, does not depend on the connection scheme of its windings. It is noted that in some cases it is difficult to obtain a complete scheme of an external power supply system. Considering that the short circuit in the traction network for the external power supply system is remote, it is proposed taking into account the reference network or traction substations as power sources, from which high-voltage transmission lines power the traction substations. Resistance of the supporting substations as power sources must takes into account connected equivalent power system.Such equivalenting should be carried out by known values of currents or short-circuit powers at the inputs of the reference substation or, if such information is not available, by the rated values of the switched-off currents or powers of the switches of high-voltage line connections.The following power schemes for traction substations are considered: each from its own supporting substation, which is part of an electrically uncoupled external power supply system; from the double-circuit high-voltage line of longitudinal power supply when it is powered from different supporting substations; from the supporting network substation, the traction substation receives power from two lines, and from this the traction substations receive power from two lines in a circle pattern.These three common cases cover all the most common power schemes for traction substations. For each of them formulas are given to determine the resulting equivalent resistance of the external power supply circuit, which should be taken into account in the replacement circuit of the traction network.


2020 ◽  
pp. 36-38
Author(s):  
R.A. Anokhin ◽  
S.N. Dubnyuk ◽  
N.І. Gaponenko ◽  
V.G. Zhuravlyov ◽  
A.V. Zhuravlyov ◽  
...  

This paper presents compact power supply system for the helium ion linac’s injector. The system consists of high-voltage modulator, power supplies of cathode filament, solenoid and arc modulator. It is designed on modern semi-conductor base. Using of the designed power supply system allowed to decrease the power consumption and to get rid of spurious capacitances and pickups. As a result of improving the continuous adjustment modulator and high-voltage pulse stabilization scheme, the accelerated beam current has increased twice.