dc power supply
Recently Published Documents


TOTAL DOCUMENTS

468
(FIVE YEARS 98)

H-INDEX

17
(FIVE YEARS 3)

2022 ◽  
Vol 12 (1) ◽  
pp. 70
Author(s):  
Muhammad Ajmal ◽  
Shahid Iqbal ◽  
Arslan Arif

This paper proposes a solar-powered resonant inverter fed a high-voltage DC power supply. In this converter, switching loss is controlled through zero-voltage switching and zero-current switching. This converter comprises a solar panel, boost converter, full-bridge LLC resonant tank, power transformer, and rectifier circuit. All power switches are operated with an interleaved switching cycle to ensure equal power flow from the tank. This proposed converter is designed to produce a regulated 19.5 KV at output, with an input voltage range of 300–350 V. The proposed converter was simulated in PSpice to verify the results.


2021 ◽  
Vol 1 (3) ◽  
pp. 1
Author(s):  
Muhammad Abrar ◽  
Lukman Hakim ◽  
Suryati Suryati

Dalam memenuhi kebutuhan pasokan energi dalam negeri, salah satu penelitian mengenai energi terbarukan yang pada saat ini dikembangkan adalah pemanfaatan bahan bakar hidrogen yang digunakan dalam Fuel Cell System. Penelitian ini bertujuan untuk meningkatkan produksi gas hidrogen yang sebelumnya hanya mengandalkan gas alam, pembuatan gas hidrogen sebagai energi terbarukan diharapkan menjadi terobosan baru dalam mendukung energi yang ramah lingkungan. Pada penelitian ini melakukan metode elektrolisis menggunakan arus listrik searah atau DC (Power Supply) dan air laut dengan volume elektrolit 1000 ml, waktu elektrolisis 2, 4, 6, 8, dan 10 menit dengan menggunakan elektroda Titanium dan Karbon dan memvariasikan tegangan 5, 10, 15, 20 dan 25 volt. Pemilihan jenis reaktor berbentuk silinder berkapasitas 1500 ml, kondisi operasi 30oC dan 1 atm. Hasil kajian menunjukkan bahwa tegangan sangat berpengaruh terhadap penguraian air laut menjadi gas hidrogen. Dengan menggunakan elektroda titanium didapat hasil flow rategas hidrogen yang paling tinggi di dapat pada tegangan 25 volt dengan waktu 8 menit sebesar 247 cc/min dengan elektroda Titanium yang tidak terdegradasi sedangkan dengan elektroda Karbon didapat 318 cc/min pada 25 volt dengan waktu 10 menit namun elektroda karbon lebih cepat terdegradasi. Sedangkan jumlah volume Sodium Hipoklorit yang terbentuk sangat dipengaruhi oleh tegangan dan waktu elektrolisis.


2021 ◽  
Author(s):  
Andrey S. Kharitonov ◽  
Regina Yu. Sarakhanova ◽  
Oleg N. Bodin ◽  
Yuri N. Zolotukhin ◽  
Sergey A. Kharitonov

2021 ◽  
Vol 2095 (1) ◽  
pp. 012002
Author(s):  
Guofu Chen ◽  
Fengjiao Dai ◽  
Wei Kang

Abstract With the development of fuel cell products and technology, power electronics researchers have proposed a variety of fuel cell DC/DC power supply topologies for the output characteristics of fuel cells. This article compares and analyzes several existing non-isolated and isolated topological structures, summarizes the respective advantages and disadvantages of different topological structures and applicable scenarios, and provides references for further indepth discussion of related issues.


2021 ◽  
Vol 1207 (1) ◽  
pp. 012005
Author(s):  
Linlin Shi ◽  
Pengfei Yu ◽  
Shilie He ◽  
Zhenwei Zhou ◽  
Linghui Meng ◽  
...  

Abstract The health state of DC-DC power supply is the key factor to determine whether the electronic equipment can operate normally. The failure and deterioration of the power supply system will lead to the collapse of the entire electronic system. The research in this paper is based on the long-term high temperature degradation test data of a certain type of DC-DC power supply. The degradation law of power supply is studied by data preprocessing and noise reduction of sensitive parameters such as input current, output current, input voltage and output voltage. On this basis, we use the method of deep learning to model the efficiency of power supply in the process of degradation test. The experimental results show that the efficiency time series modeling of power supply degradation using LSTM method can effectively reflect the law of power supply efficiency degradation. Based on the DC-DC power health management technology combining degradation test and deep learning, the advanced fault prediction model is used to reflect the change law of power supply in the real degradation process. This method has certain theoretical and engineering value for power PHM modeling and application.


2021 ◽  
Vol 2108 (1) ◽  
pp. 012054
Author(s):  
Xingyu Bai

Abstract With the rapid development of the information technology industry, the demand for data centers is gradually expanding. As the foundation of carrying many information technology services, data centers have been built and put into use on a large scale. At the same time, the characteristics of huge energy consumption are more obvious. Due to the defects of low utilization rate, heavy pollution and limited reserves of traditional fossil fuels when supplying energy for data centers, the development of green renewable energy has become an inevitable demand. This paper studies the key technologies involved in supplying power to DC power supply data center with renewable energy, and makes a case to compare the DC power supply system and the AC power supply system. This paper also pays attention to the technology of energy storage in data center, and makes an analysis to prove the advantages of energy storage data center. In addition, this paper studies and summarizes the application of multi-station integration technology and other issues.


2021 ◽  
Vol 2083 (2) ◽  
pp. 022038
Author(s):  
Xue Jie ◽  
Jinghong Zhao

Abstract In this paper, a linear phase shifting transformer based on linear motor is studied. The transformer is composed of four groups of three-phase full-bridge inverter system and a linear core. The DC power supply can be converted into three-phase alternating current through the inverter system and the linear phase shifting transformer. Compared with the traditional phase-shifting transformer, the linear phase-shifting transformer is easy to expand, easy to connect, and has better heat dissipation. The simulation results show that this scheme is feasible.


2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Anugrah Adiwilaga ◽  
Imam Taufiqurrahman

Pusat Penelitian dan Pengembangan Sumber Daya Air (PUSAIR) merupakan salah satu lembaga litbang milik kementrian PUPR yang memiliki berbagai fungsi beberapa diantaranya adalah penelitian dan pengembangan, pelayanan uji laboratorium dan lapangan, sertifikasi, inspeksi, kalibrasi, dan advis teknis di bidang sumber daya air. Seiring meningkatnya berbagai kegiatan penelitian serta kebutuhan pencatatan data yang praktis, maka PUSAIR mulai meningkatkan kemampuan beberapa alat laboratoriumnya dimana salah satunya adalah mekanisme pencatatan data. Sangat penting untuk melakukan pencatatan hasil pengukuran yang praktis, cepat dan tepat agar para peneliti dapat meningkatkan kualitas dan kapasitas penelitian. Namun kondisinya belum semua alat yang ada mendapatkan digitalisasi, salah satunya alat pembacaan ketinggian permukaan air pada model bendungan yang mana masih menggunakan alat ukur manual dan melibatkan beberapa orang untuk melakukannya serta data yang didapat perlu konversi dari catatan dikertas kepada perangkat lunak spreadsheet. Tujuan penelitian ini adalah merancang dan membuat sistem pemantauan ketinggian permukaan air pada model bendungan secara “realtime” berbasis wireless untuk memudahkan pengguna dalam kegiatan pengambilan data percobaan. Rancangan desain sistem terdiri dari 2 buah perangkat yaitu Sensor Node dan Receiver Node yang diimplementasi menggunakan Sensor Waterlevel Sensor sebagai sensor ketinggian permukaan air, mikrokontroler ATMega328 sebagai pengolah data, Xbee-Pro S2C 2.4 Ghz sebagai modul komunikasi, Buck-Converter, DC power Supply sebagai supply daya, serta LCD 16x2 dan buzzer sebagai indikator. Hasil pengujian system menunjukan bahwa komponen dan modul yang digunakan sudah bekerja sesuai fungsi yang dikendalikan mikrokontroler. Pembacaan ketinggian permukaan air oleh Etape waterlevel sensor mampu membaca dengan rata-rata penyimpangan kurang dari 1%. Pengiriman data berhasil mengirim data sebanyak 100% data ke Receiver Node sesuai dengan harapan dan tanpa adanya gangguan koneksi. Pengguna sistem dapat melakukan pengukuran dan perekaman data ketinggian air secara real time dari ruang pantau tanpa perlu mendatangi model bendungan.