scholarly journals Wrist-Based Accelerometers and Visual Analog Scales as Outcome Measures for Shoulder Activity During Daily Living in Patients With Rotator Cuff Tendinopathy: Instrument Validation Study (Preprint)

2019 ◽  
Author(s):  
Samuel Larrivée ◽  
Frédéric Balg ◽  
Guillaume Léonard ◽  
Sonia Bédard ◽  
Michel Tousignant ◽  
...  

BACKGROUND Shoulder pain secondary to rotator cuff tendinopathy affects a large proportion of patients in orthopedic surgery practices. Corticosteroid injections are a common intervention proposed for these patients. The clinical evaluation of a response to corticosteroid injections is usually based only on the patient’s self-evaluation of his function, activity, and pain by multiple questionnaires with varying metrological qualities. Objective measures of upper extremity functions are lacking, but wearable sensors are emerging as potential tools to assess upper extremity function and activity. OBJECTIVE This study aimed (1) to evaluate and compare test-retest reliability and sensitivity to change of known clinical assessments of shoulder function to wrist-based accelerometer measures and visual analog scales (VAS) of shoulder activity during daily living in patients with rotator cuff tendinopathy convergent validity and (2) to determine the acceptability and compliance of using wrist-based wearable sensors. METHODS A total of 38 patients affected by rotator cuff tendinopathy wore wrist accelerometers on the affected side for a total of 5 weeks. Western Ontario Rotator Cuff (WORC) index; Short version of the Disability of the Arm, Shoulder, and Hand questionnaire (QuickDASH); and clinical examination (range of motion and strength) were performed the week before the corticosteroid injections, the day of the corticosteroid injections, and 2 and 4 weeks after the corticosteroid injections. Daily Single Assessment Numeric Evaluation (SANE) and VAS were filled by participants to record shoulder pain and activity. Accelerometer data were processed to extract daily upper extremity activity in the form of active time; activity counts; and ratio of low-intensity activities, medium-intensity activities, and high-intensity activities. RESULTS Daily pain measured using VAS and SANE correlated well with the WORC and QuickDASH questionnaires (r=0.564-0.815) but not with accelerometry measures, amplitude, and strength. Daily activity measured with VAS had good correlation with active time (r=0.484, <italic>P</italic>=.02). All questionnaires had excellent test-retest reliability at 1 week before corticosteroid injections (intraclass correlation coefficient [ICC]=0.883-0.950). Acceptable reliability was observed with accelerometry (ICC=0.621-0.724), apart from low-intensity activities (ICC=0.104). Sensitivity to change was excellent at 2 and 4 weeks for all questionnaires (standardized response mean=1.039-2.094) except for activity VAS (standardized response mean=0.50). Accelerometry measures had low sensitivity to change at 2 weeks, but excellent sensitivity at 4 weeks (standardized response mean=0.803-1.032). CONCLUSIONS Daily pain VAS and SANE had good correlation with the validated questionnaires, excellent reliability at 1 week, and excellent sensitivity to change at 2 and 4 weeks. Daily activity VAS and accelerometry-derived active time correlated well together. Activity VAS had excellent reliability, but moderate sensitivity to change. Accelerometry measures had moderate reliability and acceptable sensitivity to change at 4 weeks.


10.2196/14468 ◽  
2019 ◽  
Vol 6 (2) ◽  
pp. e14468
Author(s):  
Samuel Larrivée ◽  
Frédéric Balg ◽  
Guillaume Léonard ◽  
Sonia Bédard ◽  
Michel Tousignant ◽  
...  

Background Shoulder pain secondary to rotator cuff tendinopathy affects a large proportion of patients in orthopedic surgery practices. Corticosteroid injections are a common intervention proposed for these patients. The clinical evaluation of a response to corticosteroid injections is usually based only on the patient’s self-evaluation of his function, activity, and pain by multiple questionnaires with varying metrological qualities. Objective measures of upper extremity functions are lacking, but wearable sensors are emerging as potential tools to assess upper extremity function and activity. Objective This study aimed (1) to evaluate and compare test-retest reliability and sensitivity to change of known clinical assessments of shoulder function to wrist-based accelerometer measures and visual analog scales (VAS) of shoulder activity during daily living in patients with rotator cuff tendinopathy convergent validity and (2) to determine the acceptability and compliance of using wrist-based wearable sensors. Methods A total of 38 patients affected by rotator cuff tendinopathy wore wrist accelerometers on the affected side for a total of 5 weeks. Western Ontario Rotator Cuff (WORC) index; Short version of the Disability of the Arm, Shoulder, and Hand questionnaire (QuickDASH); and clinical examination (range of motion and strength) were performed the week before the corticosteroid injections, the day of the corticosteroid injections, and 2 and 4 weeks after the corticosteroid injections. Daily Single Assessment Numeric Evaluation (SANE) and VAS were filled by participants to record shoulder pain and activity. Accelerometer data were processed to extract daily upper extremity activity in the form of active time; activity counts; and ratio of low-intensity activities, medium-intensity activities, and high-intensity activities. Results Daily pain measured using VAS and SANE correlated well with the WORC and QuickDASH questionnaires (r=0.564-0.815) but not with accelerometry measures, amplitude, and strength. Daily activity measured with VAS had good correlation with active time (r=0.484, P=.02). All questionnaires had excellent test-retest reliability at 1 week before corticosteroid injections (intraclass correlation coefficient [ICC]=0.883-0.950). Acceptable reliability was observed with accelerometry (ICC=0.621-0.724), apart from low-intensity activities (ICC=0.104). Sensitivity to change was excellent at 2 and 4 weeks for all questionnaires (standardized response mean=1.039-2.094) except for activity VAS (standardized response mean=0.50). Accelerometry measures had low sensitivity to change at 2 weeks, but excellent sensitivity at 4 weeks (standardized response mean=0.803-1.032). Conclusions Daily pain VAS and SANE had good correlation with the validated questionnaires, excellent reliability at 1 week, and excellent sensitivity to change at 2 and 4 weeks. Daily activity VAS and accelerometry-derived active time correlated well together. Activity VAS had excellent reliability, but moderate sensitivity to change. Accelerometry measures had moderate reliability and acceptable sensitivity to change at 4 weeks.



Medicina ◽  
2020 ◽  
Vol 57 (1) ◽  
pp. 29
Author(s):  
Yuta Suzuki ◽  
Noriaki Maeda ◽  
Junpei Sasadai ◽  
Kazuki Kaneda ◽  
Taizan Shirakawa ◽  
...  

Background and objectives: The long head of the biceps (LHB) and rotator cuff tendinopathy is the major cause of shoulder pain in competitive swimmers. The risk of tendinopathy increases with aging; however, the structural changes of LHB and rotator cuff in populations of masters swimmers have not been well examined. The purpose of this study was to investigate the prevalence of ultrasonographic abnormalities of the shoulders in masters swimmers, and the association of pain, age, and swim training with structural changes in this population. Materials and Methods: A total of 60 subjects participated in this study, with 20 masters swimmers with shoulder pain, 20 asymptomatic masters swimmers, and 20 sex- and age-matched controls. All swimmers completed a self-reported questionnaire for shoulder pain, their history of competition, and training volume. Each subject underwent ultrasonographic examination of both shoulders for pathologic findings in the LHB tendon, rotator cuff (supraspinatus (SSP) and subscapularis (SSC)) tendons, and subacromial bursa (SAB) of both shoulders and had thickness measured. Results: The prevalence of tendinosis (LHB, 48.8%; SSP, 17.5%; SSC, 15.9%), partial tear (SSP, 35.0%), and calcification (SSC, 10.0%) were higher in swimmers than in controls. LHB and SSP tendinosis were associated with shoulder pain. Older age and later start of competition were associated with an increased risk of LHB tendinosis and SSC calcification. Earlier initiation of swimming and longer history of competition were associated with an increased risk of SSP and SSC tendinosis. The thicker SSP tendon significantly increased the risk of tendinosis and partial tear. Conclusions: A high prevalence of structural changes in the rotator cuff and biceps tendons in masters swimmers reflects the effect of shoulder symptoms, aging, and swim training.



Physiotherapy ◽  
2013 ◽  
Vol 99 (4) ◽  
pp. 358-362 ◽  
Author(s):  
Chris Littlewood ◽  
Peter Malliaras ◽  
Sue Mawson ◽  
Stephen May ◽  
Stephen Walters


Physiotherapy ◽  
2015 ◽  
Vol 101 ◽  
pp. e309-e310
Author(s):  
A. Desjardins-Charbonneau ◽  
J.-S. Roy ◽  
C.E. Dionne ◽  
P. Frémont ◽  
J.C. MacDermid ◽  
...  


Author(s):  
Vishal S. Desai ◽  
Christopher L. Camp ◽  
Venkat Boddapati ◽  
Joshua S. Dines ◽  
Stephen F. Brockmeier ◽  
...  




Sign in / Sign up

Export Citation Format

Share Document