Diagnosis of Atrial Fibrillation Using Machine Learning with Wearable Devices after Cardiac Surgery (Preprint)

2021 ◽  
Author(s):  
Daisuke Hiraoka ◽  
Tomohiko Inui ◽  
Eiryo Kawakami ◽  
Megumi Oya ◽  
Ayumu Tsuji ◽  
...  

BACKGROUND Some attempts have been made to detect atrial fibrillation with a wearable device equipped with photoelectric volumetric pulse wave technology, and it is expected to be applied under real clinical conditions. OBJECTIVE This study is the second part of a two-phase study aimed at developing a method for immediate detection of paroxysmal atrial fibrillation (AF) using a wearable device with built-in PPG. The objective of this study is to develop an algorithm to immediately diagnose atrial fibrillation by wearing an Apple Watch equipped with a photoplethysmography (PPG) sensor on patients undergoing cardiac surgery and using machine learning of the pulse data output from the device. METHODS A total of 80 subjects who underwent cardiac surgery at a single institution between June 2020 and March 2021 were monitored for postoperative atrial fibrillation using telemetry monitored ECG and Apple Watch. Atrial fibrillation was diagnosed by qualified physicians from telemetry-monitored ECGs and 12-lead ECGs; a diagnostic algorithm was developed using machine learning on pulse rate data output from the Apple Watch. RESULTS One of the 80 patients was excluded from the analysis due to redness of the Apple Watch wearer. 27 (34.2%) of the 79 patients developed AF, and 199 events of AF, including brief AF, were observed. 18 events of AF lasting longer than 1 hour were observed, and Cross-correlation analysis (CCF) showed that pulse rate measured by Apple Watch was strongly correlated (CCF 0.6-0.8) with 8 events and very strongly correlated (CCF >0.8) with 3 events. The diagnostic accuracy by machine learning was 0.7952 (sensitivity 0.6312, specificity 0.8605 at the point closest to the top-left) for the AUC of the ROC curve. CONCLUSIONS We were able to safely monitor pulse rate in patients after cardiac surgery by wearing an Apple Watch. Although the pulse rate from the PPG sensor does not follow the heart rate of the telemetry monitoring ECG in some parts, which may reduce the accuracy of the diagnosis of atrial fibrillation by machine learning, we have shown the possibility of clinical application of early detection of atrial fibrillation using only the pulse rate collected by the PPG sensor. CLINICALTRIAL The use of wristband type continuous pulse measurement device with artificial intelligence for early detection of paroxysmal atrial fibrillation Clinical Research Protocol No. jRCTs032200032 https://jrct.niph.go.jp/latest-detail/jRCTs032200032

2015 ◽  
Vol 2015 (mar26 2) ◽  
pp. bcr2014208329-bcr2014208329 ◽  
Author(s):  
C. J. OSullivan ◽  
M. Sprenger ◽  
D. Tueller ◽  
F. R. Eberli

2013 ◽  
Vol 146 (4) ◽  
pp. 810-823 ◽  
Author(s):  
Patrick M. McCarthy ◽  
Adarsh Manjunath ◽  
Jane Kruse ◽  
Adin-Cristian Andrei ◽  
Zhi Li ◽  
...  

JMIR Cardio ◽  
10.2196/14857 ◽  
2020 ◽  
Vol 4 (1) ◽  
pp. e14857 ◽  
Author(s):  
Tomohiko Inui ◽  
Hiroki Kohno ◽  
Yohei Kawasaki ◽  
Kaoru Matsuura ◽  
Hideki Ueda ◽  
...  

Background Wearable devices with photoplethysmography (PPG) technology can be useful for detecting paroxysmal atrial fibrillation (AF), which often goes uncaptured despite being a leading cause of stroke. Objective This study is the first part of a 2-phase study that aimed at developing a method for immediate detection of paroxysmal AF using PPG-integrated wearable devices. In this study, the diagnostic performance of 2 major smart watches, Apple Watch Series 3 and Fitbit (FBT) Charge HR Wireless Activity Wristband, each equipped with a PPG sensor, was compared, and the pulse rate data outputted from those devices were analyzed for precision and accuracy in reference to the heart rate data from electrocardiography (ECG) during AF. Methods A total of 40 subjects from patients who underwent cardiac surgery at a single center between September 2017 and March 2018 were monitored for postoperative AF using telemetric ECG and PPG devices. AF was diagnosed using a 12-lead ECG by qualified physicians. Each subject was given a pair of smart watches, Apple Watch and FBT, for simultaneous pulse rate monitoring. The heart rate of all subjects was also recorded on the telemetry system. Time series pulse rate trends and heart rate trends were created and analyzed for trend pattern similarities. Those trend data were then used to determine the accuracy of PPG-based pulse rate measurements in reference to ECG-based heart rate measurements during AF. Results Of the 20 AF events in group FBT, 6 (30%) showed a moderate or higher correlation (cross-correlation function>0.40) between pulse rate trend patterns and heart rate trend patterns. Of the 16 AF events in group Apple Watch (workout [W] mode), 12 (75%) showed a moderate or higher correlation between the 2 trend patterns. Linear regression analyses also showed a significant correlation between the pulse rates and the heart rates during AF in the subjects with Apple Watch. This correlation was not observed with FBT. The regression formula for Apple Watch W mode and FBT was X=14.203 + 0.841Y and X=58.225 + 0.228Y, respectively (where X denotes the mean of all average pulse rates during AF and Y denotes the mean of all corresponding average heart rates during AF), and the coefficient of determination (R2) was 0.685 and 0.057, respectively (P<.001 and .29, respectively). Conclusions In this validation study, the detection precision of AF and measurement accuracy during AF were both better with Apple Watch W mode than with FBT.


2011 ◽  
Vol 27 (Supplement) ◽  
pp. PJ2_023
Author(s):  
Kenji Kawamoto ◽  
Takashi Fujiwara ◽  
Shinpei Fujita ◽  
Hideyuki Suzuki ◽  
Tsuyoshi Miyaji ◽  
...  

2019 ◽  
Author(s):  
Tomohiko Inui ◽  
Hiroki Kohno ◽  
Yohei Kawasaki ◽  
Kaoru Matsuura ◽  
Hideki Ueda ◽  
...  

BACKGROUND Wearable devices with photoplethysmography (PPG) technology can be useful for detecting paroxysmal atrial fibrillation (AF), which often goes uncaptured despite being a leading cause of stroke. OBJECTIVE This study is the first part of a 2-phase study that aimed at developing a method for immediate detection of paroxysmal AF using PPG-integrated wearable devices. In this study, the diagnostic performance of 2 major smart watches, Apple Watch Series 3 and Fitbit (FBT) Charge HR Wireless Activity Wristband, each equipped with a PPG sensor, was compared, and the pulse rate data outputted from those devices were analyzed for precision and accuracy in reference to the heart rate data from electrocardiography (ECG) during AF. METHODS A total of 40 subjects from patients who underwent cardiac surgery at a single center between September 2017 and March 2018 were monitored for postoperative AF using telemetric ECG and PPG devices. AF was diagnosed using a 12-lead ECG by qualified physicians. Each subject was given a pair of smart watches, Apple Watch and FBT, for simultaneous pulse rate monitoring. The heart rate of all subjects was also recorded on the telemetry system. Time series pulse rate trends and heart rate trends were created and analyzed for trend pattern similarities. Those trend data were then used to determine the accuracy of PPG-based pulse rate measurements in reference to ECG-based heart rate measurements during AF. RESULTS Of the 20 AF events in group FBT, 6 (30%) showed a moderate or higher correlation (cross-correlation function&gt;0.40) between pulse rate trend patterns and heart rate trend patterns. Of the 16 AF events in group Apple Watch (workout [W] mode), 12 (75%) showed a moderate or higher correlation between the 2 trend patterns. Linear regression analyses also showed a significant correlation between the pulse rates and the heart rates during AF in the subjects with Apple Watch. This correlation was not observed with FBT. The regression formula for Apple Watch W mode and FBT was X=14.203 + 0.841Y and X=58.225 + 0.228Y, respectively (where X denotes the mean of all average pulse rates during AF and Y denotes the mean of all corresponding average heart rates during AF), and the coefficient of determination (<i>R</i><sup>2</sup>) was 0.685 and 0.057, respectively (<i>P</i>&lt;.001 and .29, respectively). CONCLUSIONS In this validation study, the detection precision of AF and measurement accuracy during AF were both better with Apple Watch W mode than with FBT.


Sign in / Sign up

Export Citation Format

Share Document