Application of STATCOMs to improve static voltage stability for Vietnam power system with grid connection of large nuclear power plant

2016 ◽  
Vol 02 ◽  
pp. 50
Author(s):  
Tien, N.N.
Author(s):  
Zhang Zhichao

At present, in the typical design of China’s nuclear power plant, main generation system is connected to the power grid by 500 kV system. 500 kV system as a priority power source, 220kV system as an auxiliary power source. Independent operation of 500kV and 220kV system, improved the reliability of power supply of nuclear power plant. However, the DC 220V power system used to control the 500kV and 220kV system in the switch station of partial nuclear power project is not independently configured, and the design form of one set of DC system is used in the transformer station. In recent years, there are many accidents that AC power enters into the DC power system, resulted in the loss of power source in the transformer station. The loss of external power source in the whole plant is very significant. In this paper, the influence of AC power entering into DC power system on relay protection device is analyzed, the measures to prevent the AC power into DC power system are discussed, the necessity of independent configuration of DC control power system for the 500kV priority power system and 220kV auxiliary power supply system is analyzed.


Author(s):  
Zhenpeng Tang ◽  
Fuyu Zhao ◽  
Pengfei Wang ◽  
Li Chen ◽  
Huawei Fang

The power system frequency stability problem has been the focus of attention since 1920s. Primary frequency regulation (PFR) is one of vital methods to maintain frequency stability, especially when the power system suffers a sudden load disturbance, such as the substation tripping or generator outage accident. To a power system, the more power units participating in PFR, the frequency stability will be controlled better. With the rapid development of nuclear power units in China, the study of the nuclear power units participating in PFR of power system has becoming a pressing problem. In the present study, a detailed nonlinear dynamic mathematical model of the whole pressurized water reactor (PWR) nuclear power plant is built. The dynamic calculation codes are compiled to dynamic link library (DLL) files, which are developed by using FORTRAN language, and the compiled DLL files are embedded into MATLAB/SIMULINK simulation platform by using S-function, the control systems are designed and the whole system of PWR nuclear power plant is simulated in MATLAB/SIMULINK finally. In this method, the operation and control mode of PWR participating in PFR of power system is analyzed and simulated. The simulations results show that the PWR nuclear units are feasible in participating in PFR from safety and economy.


Author(s):  
Muhammad Aman Ullah ◽  
Arslan Qaiser ◽  
Qamar Saeed ◽  
Abdul Rehman Abbasi ◽  
Iftikhar Ahmed ◽  
...  

2014 ◽  
Vol 986-987 ◽  
pp. 196-201 ◽  
Author(s):  
Tao Zhang ◽  
Xiao Dong Ma ◽  
Yu Zhu ◽  
Gang Wang ◽  
Peng Ye

Based on extensive research, introduced the peak load regulation characteristics and capacity of different nuclear power plant (NPP) in this paper. The running mode of NPP participating in peak load regulation of power system, combined operation tactics of NPP with other peaking power source and synergistic scheduling of an integrated power generation system with wind, photovoltaic, energy storage unit and NPP were summarized, technology development trend of NPP participating in peak load regulation of power system was analyzed and forecasted.


Sign in / Sign up

Export Citation Format

Share Document