NOVEL VALIDATED REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR DETERMINATION OF GLUCOSAMINE, DIACEREIN, AND METHYL SULFONYL METHANE IN MICRO SAMPLE RAT PLASMA AND ITS APPLICATION TO PHARMACOKINETIC AND DISSOLUTION STUDIES

Author(s):  
PODILI BHAVANI ◽  
KAMMELA PRASADA RAO ◽  
SEELAM MOHAN

Objective: The main objective of this research is to develop and validate a simple, specific, precise, sensitive, cost-effective, and rapid reversed-phase high-performance liquid chromatography method for simultaneous quantification of glucosamine (GLU), diacerein (DIA) and methyl sulfonyl methane in bulk and pharmaceutical dosage forms, and micro-sample of rat plasma using ultraviolet (UV) detection, to perform the studies of drug dissolution from tablets. Methods: Sprague-Dawley rats were used for pharmacokinetic study after intravenous administration of the drug samples at dose 5 mg/kg. The drug samples were extracted by liquid-liquid extraction technique using acetonitrile, which also acted as a deproteinization agent. The separation of the analyte was carried out on a phenomena C18 column with a mobile phase composed of 0.1 % orthophosphoric acid:acetonitrile (80:20 v/v) delivered at a flow rate of 1.0 ml/min, and separation has been monitored by a UV detector, at detection of the wavelength of 285 nm. Results: This method was proven to be linear over a concentration range of 30–450 μg/ml for GLU, 2–30 μg/ml for DIA, and 10–150 μg/ml for methyl sulfonyl methane with a correlation coefficient of 0.999. The retention time of GLU, DIA, and methyl sulfonyl methane were 2.89, 6.32, and 9.87 min, respectively. Recovery of the drugs was found to be in the range of 98.0–102.0%. Validation results were found to be satisfactory and the method applicable for bulk and formulation analysis. Hence, it was evident that the proposed method was said to be a suitable one for the regular analysis and quality control of pharmaceutical preparations which contain these active drugs either individually or in combination. Conclusion: The validation results were in good agreement with acceptable limits. Relative standard deviation values which are less than 2.0% are indicating the accuracy and precision of this method. The usefulness of the method is that the common chromatographic conditions have been adopted for assay, dissolution, and pharmacokinetic studies. This developed method showed reliable, precise, and accurate results under optimized conditions.

Author(s):  
Mannem Durga Babu ◽  
Kesana Surendrababu

Objective: The objective of the study was to develop and validate a novel, specific, precise, and simple reversed-phase high-performance liquid chromatography method for the estimation of guaifenesin present in methocarbamol API and its pharmaceutical dosage forms. Methods: The baseline separation for methocarbamol and guaifenesin was achieved by utilizing a Inertsil ODS C18 (250 mm × 4.6 mm) 5 μm column particle size and an isocratic elution method. The mobile phase contains a mixture of water and acetonitrile in the ratio of 70:30 v/v, respectively. The flow rate of the mobile phase was 1.0 mL/min with a column temperature of 25°C and detection wavelength at 272 nm. The method was validated for a limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and reproducibility with the help of the exhibit and simulated samples. Results: The LOD for guaifenesin was 0.62 μg/mL. The LOQ for guaifenesin was 1.87 μg/mL. The correlation coefficient obtained for impurity was >0.99. The recovery was obtained for impurity was 106.56% at 50%, 95.20% at 100%, and 100.45% at 150%. In tablet analysis, we can found 0.26% (<0.5%). Conclusion: The developed method was validated as per the ICH guidelines with respect to specificity, precision, linearity, accuracy, LOD and quantification, ruggedness, robustness, and solution stability.


2017 ◽  
Vol 2017 ◽  
pp. 1-7
Author(s):  
Paula Karina S. Uchoa ◽  
Leandro Bezerra de Lima ◽  
Antonia T. A. Pimenta ◽  
Maria da Conceição F. de Oliveira ◽  
Jair Mafezoli ◽  
...  

A high-performance liquid chromatography method was developed and validated for the quantification of the cytotoxic compounds produced by a marine strain ofAspergillus niger. The fungus was grown in malt peptone dextrose (MPD), potato dextrose yeast (PDY), and mannitol peptone yeast (MnPY) media during 7, 14, 21, and 28 days, and the natural products were identified by standard compounds. The validation parameters obtained were selectivity, linearity (coefficient of correlation > 0.99), precision (relative standard deviation below 5%), and accuracy (recovery > 96).


2014 ◽  
Vol 6 (16) ◽  
pp. 6560-6564 ◽  
Author(s):  
Wuxiang Zhang ◽  
Yicong Su ◽  
Jiangu Shi ◽  
Maosheng Zhang ◽  
Bide Wu ◽  
...  

In this paper, a high performance liquid chromatography technique is established for quantification of paraquat in blood.


2008 ◽  
Vol 30 (3) ◽  
pp. 341-346 ◽  
Author(s):  
Maria Bernadete Sousa Maia ◽  
Ismael Leite Martins ◽  
Demétrius Fernandes do Nascimento ◽  
Adriano Nunes Cunha ◽  
Francisco Evanir Gonçalves de Lima ◽  
...  