scholarly journals RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANIOUS ESTIMATION AND FORCED DEGRADATION STUDIES OF LAMIVUDINE AND RALTEGRAVIR IN SOLID DOSAGE FORM

2018 ◽  
Vol 10 (6) ◽  
pp. 242
Author(s):  
Juluri Krishna Dutta Tejaswi ◽  
R. Govinda Rajan

Objective: A stability indicating reverse phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the estimation of the combined tablet formulation of lamivudine (LAM) and raltegravir (RAL) in dosage forms and its API.Methods: Chromatographic separation was achieved on inertsil ODS C18 5 µm (4.6 X 150 mm) using a mobile phase (MP) consisting of a mixture of mixed orthophosphoric acid (OPA): acetonitrile (ACN) in the ratio 50:50 v/v which was determined at 242 nm respectively. Results: The assay of LAM and RAL was performed with tablets, and the % assay was found to be 100.12 and 99.89 which shows that the method is useful for routine analysis. The linearity of LAM and RAL was found to be linear with a correlation coefficient of 0.998 and 0.999, which shows that the method is capable of producing good sensitivity. The retention time of LAM and RAL was 1.99 min and 4.34 min respectively; linearity range was found to lie from 15 µg/ml to 75 µg/ml for LAM, 30 µg/ml to 150 µg/ml for RAL with a correlation coefficient of 0.999 respectively. Forced degradation studies were conducted in acidic, basic, thermal, photolytic and peroxide where all the degradation peaks were monitored.Conclusion: The proposed HPLC method was found to be simple, specific, precise, accurate, rapid and economical for simultaneous estimation of LAM and RAL in bulk and tablet dosage form. Thus the validated economical method was applied for forced degradation study of LAM and RAL tablet.

Author(s):  
D. Chinababu

Aim: The objective of the study was simplest, accurate, precise and robust reversed phase high performance liquid chromatographic (RP-HPLC) method was developed for the estimation of Velpatasvir (VEL) and Sofosbuvir (SOF) in the bulk and its tablet dosage form. Study Design: The Quantitative and Qualitative estimation and designed forced degradation study of Velpatasvir & Sofosbuvir by RP-HPLC. Place and Duration of Study: The study was carried at Santhiram College of Pharmacy and time taken 4 months. Method: The method was attained by used Waters( 5µm, C18 250 x 4.6 mm) column with mobile phase consists of  0.5 mM disodium hydrogen phosphate buffer pH adjusted to 6.5, with Orthophosphoric acid and Methanol in the ratio of 78:22 v/v, a flow rate of 1.0 mL/min and ultraviolet detection at 285 nm. Results: The method was validated as per ICH guidelines with different parameters, the mean retention times of VEL and SOF were found to be 2.8 & 4.7 min respectively. The resolution between VEL and SOF was found to be 10.66. The Correlation coefficients for calibration curves within the detection range of 32.5 - 97.5 and 125 - 375 µg/mL were 0.999 for VEL and SOF respectively. The LOD and LOQ for VEL and SOF were found to be 0.0068-0.029 µg/mL and 0.104-0.342 µg/mL respectively. Conclusion: The results were indicated that the developed method was used for the routine analysis of VEL & SOF combined form in bulk and its commercial formulation. To the best of our knowledge, there was no method of RP-HPLC for the determination of VEL alone or in combination with SOF molecule.


Author(s):  
B. Anjaneyulu Reddy ◽  
Md. Irshad Alam ◽  
Nazia Khanam ◽  
P. R. Adhakrishnanand

Objective: To develop an innovative, rapid, simple, cost effective, stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method for simultaneous estimation of ledipasvir (LP) and sofosbuvir (SB) in combination pill dosage form. Methods: The method was developed using C8 column, 250 mm x 4.6 mm, 5mm using mobile section comprising of 0.1% (v/v) orthophosphoric acid buffer at pH 2.2 and acetonitrile in the ratio of 45:55 that was pumped through the column at a flow rate of 0.8 ml/min. Temperature was maintained at 30 °C, the effluents were monitored at 260 nm with the help of usage of PDA detector. Results: The retention time of LP and SB were found to be 2.246 min and 3.502 min. The approach was found to be linear with the variety of 9-36 µg/ml and 40-240 μg/ml for LP and SB respectively, the assay of estimated compounds were found to be 99.65% and 99.73% w/v for LP and SB respectively. Conclusion: The pressured samples changed into analyzed and this proposed a technique turned into determined to be particular and stability indicating as no interfering peaks of decay compound and excipients were observed. Hence, the approach was easy and economical that may be efficiently applied for simultaneous estimation of both LP and SB in bulk and combination tablet system.


Author(s):  
Juluri Krishna Dutta Tejaswi ◽  
Govinda Rajan R

Objective: A stability indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the estimation of emtricitabine (EMT), rilpivirine (RIL), and tenofovir alafenamide (TAF) in combined dosage forms and its API.Methods: Chromatographic separation was achieved on Waters ACQUITY RP-HPLC with PDA detector having Zodiac C18 Column (250×4.6×5μ) using mobile phase mixture of phosphate buffer: acetonitrile in the ratio of 40:60 v/v at 262 nm.Results: The assay was performed with tablets, and the % assay was found to be 100.104 for EMT, 99.74 for RIL, and 102.41 for TAF which shows that the method is useful for routine analysis. The linearity was found to be linear with a correlation coefficient of 0.999, which shows that the method is capable of producing good sensitivity. The retention time (RT) of EMT, RIL, and TAF using optimum conditions was found to be 2.517, 3.273, and 6.697 min. Forced degradation studies (FDS) were performed on sample using acid, base, thermal, photolytic, and peroxide degradation.Conclusion: Due to its simplicity, rapidness, high precision, and low RT value, this method was successfully applied to the estimation of EMT, RIL, and TAF combined dosage form. The drugs were found to be stable at FDS, and the net degradation was found to be within the limits.


2020 ◽  
Vol 13 (3) ◽  
pp. 206-216
Author(s):  
Madhusudan Bhoir ◽  
Nutan Rao

The objective of the study was to develop and validate a novel, stability indicating, simple, rapid, accurate, precise and isocratic reverse-phase high-performance liquid chromatographic (RP-HPLC) method for simultaneous estimation of benserazide HCl and levodopa in a marketed formulation. Chromatographic separation was achieved by using C18 Cosmosil 4.6 × 250 mm column with a mixture of phosphate buffer pH 2 and acetonitrile in proportion of 95:5 as mobile phase at a flow rate of 1.0 ml/min and column temperature 25°C. The detection was carried out at 210 nm using UV detector. The retention time for benserazide and levodopa was found to be 3.1 minutes and 6.6 minutes respectively and recoveries from tablet were between 98 and 102 %.


Author(s):  
Neha Desai ◽  
Munira Momin ◽  
Upasana Singh ◽  
Tabassum Khan ◽  
Atul Sherje

Objective: The present work was undertaken with an aim to develop and validate a rapid reverse-phase high-performance liquid chromatography (RP-HPLC) method for the estimation of curcumin and cyclosporine in the capsule dosage form. Methods: The RP-HPLC method for the simultaneous estimation of curcumin and cyclosporine was developed using Agilent (Infinity 1260) HPLC system and Eclipse XDB-C18 (4.6 x 150 mm i.d., 5µ) stationary phase. The optimized mobile phase comprised of acetonitrile: water: methanol (50: 10: 40 v/v/v) pumped at a flow rate of 0.5 ml/min. Separation of drugs was achieved in an isocratic mode and elution was monitored using PDA detector at 214 nm. The method was validated as per ICH-Q2R1 guidelines. Results: Retention time of the curcumin and cyclosporine were found to be 3.073 min and 6.373 min with the correlation coefficient (R2) of 0.9993 and 0.998 respectively. The response of curcumin and cyclosporine was found linear in the concentration range of 8-48 μg/ml and 4-24 μg/ml respectively. The percent recovery values were found in the range of 97-103% indicating satisfactory accuracy of the method. The percent relative standard deviation (% RSD) values for the precision study was less than 2 which suggest that the method is precise. Conclusion: The proposed method was found accurate, precise and specific for the determination of curcumin and cyclosporine in bulk as well as in capsule dosage form. Thus, the present method can be used for routine analysis and quality control of curcumin and cyclosporine in bulk and capsule dosage form.


Author(s):  
BHOOMI D PATEL ◽  
MEHTA BHAVYA ◽  
ANKIT B CHAUDHARY

Objective: The objective of the study was to develop and validate reverse-phase high-performance liquid chromatography (RP-HPLC) method and apply method to tablet dosage form. Methods: A simple, rapid, economical, precise, and accurate RP-HPLC method for simultaneous estimation of lamivudine and zidovudine in their combined dosage form has been developed. Results: A RP-HPLC method was developed for the simultaneous estimation of lamivudine and zidovudine. In their combined dosage form has been developed. The separation was achieved by LC-C18 column (150 mm ×4.6 mm, 5 μm) and water: methanol (65:35v/v) as mobile phase, at a flow rate of 0.8 ml/min. Detection was carried out at 272 nm. Retention time of lamivudine and zidovudine was found to be 3.007 min and 4.647, respectively. The method has been validated for linearity, accuracy, and precision. The assay method was found to be linear from 50% to 150% for lamivudine and zidovudine. Conclusion: Developed method was found to be accurate, precise, and rapid for simultaneous estimation of lamivudine and zidovudine in their combined dosage form.


Author(s):  
T. Hemant Kumar ◽  
Samata Samantaray ◽  
D. Gowri Sankar

A simple, specific, accurate, and precise RP-HPLC method was developed and validated for the simultaneous estimation of Metoprolol Succinate and Olmesartan Medoxomil in pharmaceutical formulation with forced degradation studies. The method was developed using Enable C 18G column (250 ×4.6 mm, 5 μm) with mobile phase consisting of methanol and water (pH adjusted to 3.5 with orthophosphoric acid in the ratio of 80: 20 % v/v with a flow rate of 1 mL/min. The UV detection was carried out at 240 nm. The retention time for Metoprolol Succinate and Olmesartan Medoxomil were found to be 3.986 and 6.092 min, respectively. The proposed method was validated for linearity, range, accuracy, precision, robustness, LOD, and LOQ. Linearity was observed over a concentration range 4-40 μg/mL for Metoprolol Succinate (r2 = 0.9999) and 5-60 μg/ml for Olmesartan Medoxomil (r2 = 0.9999). The % RSD for Intraday and Interday precision was found to be 0.57 and 0.68 for Metoprolol Succinate and 0.52 and 0.41 for Olmesartan Medoxomil. The LOD and LOQ were found to be 0.1143 μg/mL and 0.3565 μg/mL for Metoprolol Succinate and LOD and LOQ were found to be 0.0563 and 0.1782 μg/mL for Olmesartan Medoxomil respectively.


Author(s):  
Juluri Krishna Dutta Tejaswi ◽  
Govinda Rajan R

Objective: A stability indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the estimation of emtricitabine (EMT), rilpivirine (RIL), and tenofovir alafenamide (TAF) in combined dosage forms and its API.Methods: Chromatographic separation was achieved on Waters ACQUITY RP-HPLC with PDA detector having Zodiac C18 Column (250×4.6×5μ) using mobile phase mixture of phosphate buffer: acetonitrile in the ratio of 40:60 v/v at 262 nm.Results: The assay was performed with tablets, and the % assay was found to be 100.104 for EMT, 99.74 for RIL, and 102.41 for TAF which shows that the method is useful for routine analysis. The linearity was found to be linear with a correlation coefficient of 0.999, which shows that the method is capable of producing good sensitivity. The retention time (RT) of EMT, RIL, and TAF using optimum conditions was found to be 2.517, 3.273, and 6.697 min. Forced degradation studies (FDS) were performed on sample using acid, base, thermal, photolytic, and peroxide degradation.Conclusion: Due to its simplicity, rapidness, high precision, and low RT value, this method was successfully applied to the estimation of EMT, RIL, and TAF combined dosage form. The drugs were found to be stable at FDS, and the net degradation was found to be within the limits.