scholarly journals RP-HPLC Method development, Validation and Forced Degradation for Simultaneous estimation of Benserazide HCl and Levodopa in a Marketed Formulation

2020 ◽  
Vol 13 (3) ◽  
pp. 206-216
Author(s):  
Madhusudan Bhoir ◽  
Nutan Rao

The objective of the study was to develop and validate a novel, stability indicating, simple, rapid, accurate, precise and isocratic reverse-phase high-performance liquid chromatographic (RP-HPLC) method for simultaneous estimation of benserazide HCl and levodopa in a marketed formulation. Chromatographic separation was achieved by using C18 Cosmosil 4.6 × 250 mm column with a mixture of phosphate buffer pH 2 and acetonitrile in proportion of 95:5 as mobile phase at a flow rate of 1.0 ml/min and column temperature 25°C. The detection was carried out at 210 nm using UV detector. The retention time for benserazide and levodopa was found to be 3.1 minutes and 6.6 minutes respectively and recoveries from tablet were between 98 and 102 %.

2018 ◽  
Vol 8 (6-s) ◽  
pp. 78-82 ◽  
Author(s):  
Vishal Singh Solanki ◽  
RAM SINGH BISHNOI ◽  
Raviraj Baghel ◽  
Deepti Jain

A simple precise and economical reverse phase high performance liquid chromatographic method has been developed and validated for the simultaneous estimation of Cilnidipine (CDP), Atenolol (ATL) and Chlorthalidone (CTD).The chromatographic separation was achieved by using Hypersil- keystone C18 (4.6 x 250mm, 5μm) under isocratic conditions The mobile phase consisted of methanol and triple distilled water (80/20, v/v) having pH 7 with a flow rate of 1.0 mL/min. The eluents were monitored at 225 nm for simultaneous measurement.The selected chromatographic conditions were found to effectively separate CDP (Rt: 3.25 min), ATL (Rt: 5.366 min) and CTD (Rt: 9.025 min) having good resolution. The developed method was validated for linearity, accuracy, precision, LOD, LOQ, robustness and for system suitability parameters as per ICH guidelines. In this study, an excellent linearity was obtained with r2 = 0.999, r² = 0.999, r² = 1, for CDP, ATL and CTD respectively. The developed chromatographic method proved to be simple, precise, accurate, robust and reproducible Thus, this method would be employed for routine simultaneous quantification of CDP, ATL and CTD in bulk form or tablet dosage form.   Keywords: Cilnidipine, Atenolol and Chlorthalidone, RP-HPLC.


2018 ◽  
Vol 10 (4) ◽  
pp. 111 ◽  
Author(s):  
Vandana Jain ◽  
Sultana Shaikh

Objective: To develop a novel, accurate, precise and linear reverse phase high performance liquid chromatographic (RP-HPLC) method for simultaneous qualitative and quantitative estimation of ellagic acid and quercetin in an ayurvedic formulation and validate as per international conference on harmonization (ICH) guidelines.Methods: In the present work, good chromatographic separation was achieved isocratically using a shim-pack HPLC C18 column (4.6 x 250 mm, 5μm) and a mobile phase consisting of 0.02 M potassium dihydrogen orthophosphate buffer (pH adjusted to 3.5 with orthophosphoric acid) and acetonitrile in the ratio 60:40, at flow rate of 1.2 ml/min and column temperature maintained at 35 °C. The effluents obtained were monitored at 255 nm with UV-visible detector.Results: The retention time of ellagic acid and quercetin were found to be 1.65 min and 2.94 min respectively. Linearity of ellagic acid and quercetin were tested in the range of 6-14 ppm and 3-11 ppm respectively. The correlation coefficient for ellagic acid and quercetin were 0.997 and 0.993 respectively. The high recovery values (98 %-102 %) indicate a satisfactory accuracy. The low percent relative standard deviation (% RSD) values in the precision study reveals that the method is precise.Conclusion: The developed method is novel, simple, precise, rapid, accurate and reproducible for simultaneous quantitative estimation of ellagic acid and quercetin in an ayurvedic formulation. Hence the developed method can be used for quantitative analysis and quality control of extracts and commercial samples of other plant species and formulation containing these two markers.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (02) ◽  
pp. 39-46
Author(s):  
Babu D. China ◽  
◽  
C. Madhusudhana Chetty ◽  
Sk. Mastanamma

A simple, accurate, precise and robust reversed phase high performance liquid chromatographic (RP-HPLC) method was developed for the estimation of Ertugliflozin (ETZ) and metformin (MFN) in bulk and in tablet dosage form. The method was carried out by used Waters (5μm, C18 250 x 4.6 mm) column with mobile phase consists of 0.75 mM sodium dihydrogen orthophosphate buffer pH adjusted to 8.5, with NaOH, and acetonitrile in the ratio of 60:40 v/v, a flow rate of 1.5 mL/min and photodiode detection at 263 nm. The method was validated as per ICH guidelines with different parameters, the mean retention times of ertugliflozin and metformin were found to be 3.5& 2.0 min, respectively. The correlation coefficient values of calibration curves were found to be 0.999 for both ETZ and MFN, respectively. The LOD and LOQ for ertugliflozin and metformin were found to be 0.02-0.06 μg/mL and 17.5-58.3 μg/mL respectively.


2021 ◽  
Vol 11 (6) ◽  
pp. 54-61
Author(s):  
Khanderao Rajaram Jadhav

In the present work new, Simple Reversed-Phase High Performance Liquid Chromatographic method was developed and validated for the estimation of Melatonin in tablets. A sharp peak was obtained 7.125 min using Methanol: Phosphate buffer (PH 3.0) in the ratio of 40:60 as mobile phase at a flow rate of 1.0 ml/min, on HPLC Waters 515 system containing UV detector with Empower software. The separation was achieved on the C18 analytical column (250 mm × 4.6 mm, 5.0 μm). The detection was carried out at 223 nm. The method gave good resolution and suitable retention time. The results of the analysis in this method were validated in terms of specificity, accuracy, precision, linearity, and range. The method was found to be reliable, reproducible, rapid, and economic. The RP-HPLC method developed in this study showed specificity and selectivity with linearity in the working range and good precision and accuracy, making it very suitable for the estimation of Melatonin in tablets.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (08) ◽  
pp. 12-16
Author(s):  
S Vidyadhara ◽  
◽  
L. S Reddyvalam ◽  
T. Koduri ◽  
P. K. Borra ◽  
...  

A simple, accurate, precise high-performance liquid chromatographic (HPLC) method has been developed and validated for the simultaneous determination of abacavir sulphate (ABA) and lamivudine (LAM) in combined dosage form. Separation was performed on a C18 column [Agilent ODS UG 5 column, 250 mm x 4.5 mm], with methanol: water (50:50 V/V) isocratic elution using a flow rate of 1mL/min. Good sensitivity was observed with UV detection at 277 nm. After method development, the interference of other active compounds and excipients, repeatability and linearity, were investigated. Retention times of LAM and ABA were found to be 3.3 and 6.3 min, respectively. The method was validated over the range from 2.5-12.5 μg/mL for LAM and 5-25 μg/mL for ABA with correlation coefficients of 0.9997 and 0.9996, respectively. This method was shown to be accurate, robust, selective, linear, and repeatable and can be successfully employed in routine quality control for the simultaneous analysis of ABA and LAM in tablets.


Author(s):  
Zubaidur Rahman ◽  
Vijey Aanandhi M ◽  
Sumithra M

Objective: A simple, novel, sensitive, rapid high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for quantitative determination of atomoxetine HCl (ATH) in bulk and formulations.Methods: The chromatographic development was carried out on RP-HPLC. The column used as Xterra RP 18 (250 mm × 4.6 mm, 5 μ particle size), with mobile phase consisting of methanol: water 80:20 V/V. The flow rate was 1.0 mL/min and the effluents were monitored at 270 nm.Results: The retention time was found to be 5.350 min. The method was validated as per International Conference on Harmonization Guideline with respect to linearity, accuracy, precision, and robustness. The calibration curve was found to be linear over a range of 2–10 μg/mL with a regression coefficient of 0.9999. The method has proved high sensitivity and specificity.Conclusion: The results of the study showed that the proposed RP-HPLC method was simple, rapid, precise and accurate which is useful for the routine determination of ATH in bulk drug and in its pharmaceutical dosage form.


Author(s):  
T Hemant Kumar ◽  
CH. ASHA ◽  
D. GOWRI SANKAR

Objective: To develop and validate a simple, specific, accurate, precise and sensitive reverse phase high performance liquid chromatographic (RP-HPLC) method with forced degradation studies for the simultaneous estimation of amlodipine besylate and irbesartan in the pharmaceutical formulation. Methods: The chromatographic separation of the two drugs were achieved using Enable C 18G column (250 ×4.6 mm; 5 µm) in isocratic mode with mobile phase consisting of sodium acetate buffer (pH 4.0) and acetonitrile (30:70, % v/v) with a flow rate of 0.6 ml/min. Ultraviolet(UV) detection was carried out at 238 nm. The proposed method was validated for linearity, range, accuracy, precision, robustness, limit of detection (LOD) and limit of quantification (LOQ). The tablet formulation was subjected to stress conditions of degradation including acidic, alkaline, oxidative, thermal and photolysis. Results: The retention time for amlodipine besylate and irbesartan were found to be 5.512 and 6.321 min respectively. Linearity was observed over a concentration range 4-32 µg/ml for amlodipine besylate (r2 =0.9999) and 10-70 µg/ml for Irbesartan (r2 =0.9998). The % relative standard deviation (RSD) for Intraday and Interday precision was found to be 0.436 and 0.699 for amlodipine besylate and 0.435 and 0.30 for irbesartan. Amlodipine besylate shown stability towards acidic and thermal whereas in basic, oxidative and photolytic it shown less stability in which it degraded to more extent. Irbesartan shown stability towards thermal conditions whereas in remaining conditions it degrades to more extent especially in oxidative conditions. Conclusion: The developed reverse phase high performance liquid chromatographic (RP-HPLC) method was also found to be simple, precise and sensitive for the simultaneous determination of amlodipine besylate and irbesartan in the tablet dosage form.


Author(s):  
B. Anjaneyulu Reddy ◽  
Md. Irshad Alam ◽  
Nazia Khanam ◽  
P. R. Adhakrishnanand

Objective: To develop an innovative, rapid, simple, cost effective, stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method for simultaneous estimation of ledipasvir (LP) and sofosbuvir (SB) in combination pill dosage form. Methods: The method was developed using C8 column, 250 mm x 4.6 mm, 5mm using mobile section comprising of 0.1% (v/v) orthophosphoric acid buffer at pH 2.2 and acetonitrile in the ratio of 45:55 that was pumped through the column at a flow rate of 0.8 ml/min. Temperature was maintained at 30 °C, the effluents were monitored at 260 nm with the help of usage of PDA detector. Results: The retention time of LP and SB were found to be 2.246 min and 3.502 min. The approach was found to be linear with the variety of 9-36 µg/ml and 40-240 μg/ml for LP and SB respectively, the assay of estimated compounds were found to be 99.65% and 99.73% w/v for LP and SB respectively. Conclusion: The pressured samples changed into analyzed and this proposed a technique turned into determined to be particular and stability indicating as no interfering peaks of decay compound and excipients were observed. Hence, the approach was easy and economical that may be efficiently applied for simultaneous estimation of both LP and SB in bulk and combination tablet system.


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Sadana Gangishetty ◽  
Surajpal Verma

The present work describes a simple, rapid, and reproducible reverse phase high performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of clarithromycin (CLA) and paracetamol (PCM). C18 column (Kromasil ODS, 5 µm, 250 × 4.6 mm) and a mobile phase containing phosphate buffer (0.05 M) along with 1-octane sulphonic acid sodium salt monohydrate (0.005 M) adjusted to pH 3.2: acetonitrile (50 : 50 v/v) mixture was used for the separation and quantification. The flow rate was 1.0 mL/min and the eluents were detected by UV detector at 205 nm. The retention times were found to be 2.21 and 3.73 mins, respectively. The developed method was validated according to ICH guidelines Q2 (R1) and found to be linear within the range of 75–175 µg/mL for both drugs. The developed method was applied successfully for assay of clarithromycin and paracetamol in their combined in-house developed dosage forms and in vitro dissolution studies.


Author(s):  
D. Chinababu

Aim: The objective of the study was simplest, accurate, precise and robust reversed phase high performance liquid chromatographic (RP-HPLC) method was developed for the estimation of Velpatasvir (VEL) and Sofosbuvir (SOF) in the bulk and its tablet dosage form. Study Design: The Quantitative and Qualitative estimation and designed forced degradation study of Velpatasvir & Sofosbuvir by RP-HPLC. Place and Duration of Study: The study was carried at Santhiram College of Pharmacy and time taken 4 months. Method: The method was attained by used Waters( 5µm, C18 250 x 4.6 mm) column with mobile phase consists of  0.5 mM disodium hydrogen phosphate buffer pH adjusted to 6.5, with Orthophosphoric acid and Methanol in the ratio of 78:22 v/v, a flow rate of 1.0 mL/min and ultraviolet detection at 285 nm. Results: The method was validated as per ICH guidelines with different parameters, the mean retention times of VEL and SOF were found to be 2.8 & 4.7 min respectively. The resolution between VEL and SOF was found to be 10.66. The Correlation coefficients for calibration curves within the detection range of 32.5 - 97.5 and 125 - 375 µg/mL were 0.999 for VEL and SOF respectively. The LOD and LOQ for VEL and SOF were found to be 0.0068-0.029 µg/mL and 0.104-0.342 µg/mL respectively. Conclusion: The results were indicated that the developed method was used for the routine analysis of VEL & SOF combined form in bulk and its commercial formulation. To the best of our knowledge, there was no method of RP-HPLC for the determination of VEL alone or in combination with SOF molecule.


Sign in / Sign up

Export Citation Format

Share Document