scholarly journals STABILITY-INDICATING METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF ROSUVASTATIN CALCIUM IN PHARMACEUTICAL DOSAGE FORM BY REVERSE PHASE-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Author(s):  
AWDHUT PIMPALE ◽  
RAJENDRA KAKDE

Objective: The present work was focused on the development and validation of the reversed-phase high-performance liquid chromatography (RP-HPLC) method, which is simple, rapid, precise, accurate, sensitive, economical, and stability-indicating for the quantification of rosuvastatin calcium in bulk and tablet formulation. Methods: The separation was attained on reversed-phase Princeton (C18) column with dimensions (250 mm × 4.6 mm, 5μ) employing buffer, which is a mixture of water (pH 3.0, adjusted with orthophosphoric acid) and methanol in the ratio (20:80) v/v as mobile phase, at flow rate 1.0 ml/min. and detection was carried out at wavelength 240 nm. The retention time under the optimized condition of rosuvastatin calcium was found to be 2.844 min. Results: The linearity of the method was demonstrated in the concentration range of 6-16 µg/ml for rosuvastatin calcium with a correlation coefficient (r2) of 0.9999. The percentage relative standard deviation was ˂2% and percentage recovery was found to be 100.12-101.37% for rosuvastatin calcium. The assay of marketed tablet formulations was found to be 98.99%. Conclusion: The developed RP-HPLC technique was found to be simple, specific, sensitive, rapid, linear, accurate, precise, and economical and will be used for regular quality control of rosuvastatin calcium in bulk and tablet formulations.

Author(s):  
PULAGURTHA BHASKARARAO ◽  
GOWRI SANKAR DANNANA

Objective: Noscof tablet is a fixed dosage combination formulation having diphenhydramine (DH), ephedrine (ED), noscapine (NP), and glycerol glycolate (GG). A sensitive, selective, accurate, precise, and stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) method with photodiode array detection has been developed and validated for simultaneous analysis of DH, ED, NP, and GG in bulk drug and Noscof tablets. Methods: Reversed-phase chromatographic separation and analysis of DH, ED, NP, and GG were done on an Altima C18 column with 0.01 M KH2PO4 buffer (pH 3.5) and acetonitrile (50:50%, v/v) as mobile phase at 0.8 ml/min flow rate in isocratic mode. Detection was performed at 260 nm. The method was validated in harmony with International Conference on Harmonization (ICH) guidelines. The tablet sample solution was subjected to diverse stress conditions using ICH strategy such as hydrolytic degradation (neutral - with distilled water, alkaline - with 2 N NaOH, and acidic - with 2 N HCl), oxidation (with 10% H2O2), photodegradation (exposing to UV light), and dry heat degradation (exposing to 105°C). Results: Using the above stated chromatographic conditions, sharp peaks were obtained for ED, NP, DH, and GG with retention time of 3.272 min, 4.098 min, 5.467 min, and 6.783 min, respectively. Good regression coefficient values were obtained in the range of 2–12 μg/ml for ED, 3.75–22.5 μg/ml for NP, 3.125–18.75 μg/ml for DH, and 25–150 μg/ml for GG. The quantification limits were 0.181 μg/ml, 0.187 μg/ml, 0.246 μg/ml, and 1.114 μg/ml for ED, NP, DH, and GG, respectively. The values of validation parameters are within the acceptance limits given by ICH. The ED, NP, DH, and GG showed more percent of degradation in acid condition and less percent of degradation in the neutral condition. The peaks of degradants did not interfere with the peaks of analytes. ED, NP, DH, and GG were assessed with a good percentage of the assay (near to 100%) and low percent relative standard deviation (<2%) in Noscof tablets using the proposed method. Conclusion: The stability indicating RP-HPLC method developed was suitable for quantifying ED, NP, DH, and GG simultaneously in bulk as well as in tablet formulation.


2020 ◽  
Vol 10 (4) ◽  
pp. 79-86
Author(s):  
Awdhut Pimpale ◽  
Rajendra Kakde

A Simple, precise, and accurate stability-indicating reversed-phase high-performance liquid chromatography method has been established for the simultaneous estimation of rosuvastatin calcium and fenofibrate in combined bulk and tablet formulation. The chromatographic separation was performed on reverse phase Princeton (C18) (250 mm x 4.6 mm, 5µ) column with mobile phase as a mixture of water (pH adjusted to 3.0 with orthophosphoric acid) and acetonitrile in the ratio (40:60) v/v at the flow rate 1.0 ml/min. Detection was carried out at wavelength 240 nm. The retention time under the optimized condition of Rosuvastatin calcium and Fenofibrate was found to be 2.485 & 3.905 minutes respectively. The calibration curve was linear in the range of 6-16 µg/ml and 87-232 µg/ml for rosuvastatin calcium and fenofibrate with a correlation coefficient of 0.9999 and 0.9994 respectively. Relative standard deviation values for all key parameters were less than 2.0%. The percentage recovery was found to be 99.66-100.37% and 99.13-100.44% for rosuvastatin calcium and fenofibrate respectively. The developed reversed-phase high-performance liquid chromatography method was found to be simple, specific, sensitive, rapid, linear, accurate, precise, and economical, and could be used for regular quality control of rosuvastatin calcium and fenofibrate in bulk and tablet formulations.  Keywords: Rosuvastatin calcium, Fenofibrate, RP-HPLC, Method validation, ICH guidelines.


Author(s):  
SAILAJA B ◽  
SRAVANA KUMARI K

Objective: The present work was focused on the development and validation of reverse-phase high-performance liquid chromatography (RP-HPLC) method which is simple, rapid, precise, accurate, sensitive, economical, and stability indicating for the quantitation of rosuvastatin calcium in bulk and tablet formulation. Methods: The separation was attained on Waters Symmetry C18 column with dimensions 150×4.6 mm, 5 mm particle size employing 0.1% orthophosphoric acid buffer:acetonitrile in the ratio of 55:45% v/v as mobile phase, which was pumped at a rate of 1.0 ml/min and detected at a wavelength of 241 nm. Results: The linearity of the method was demonstrated in the concentration range of 2–12 μg/ml for rosuvastatin calcium with a correlation coefficient (r2) of 0.999, percentage drug recovery was found to be 100.22–101.16%, and percentage relative standard deviation <2. Limit of detection and limit of quantitation values were found to be 0.013 μg/ml and 0.042 μg/ml, respectively, and assay of marketed tablet formulation was found to be 99.76%. Conclusion: The developed RP-HPLC method was found to be simple, specific, sensitive, rapid, linear, accurate, precise, and economical and could be used for regular quality control of rosuvastatin calcium in bulk and tablet formulation.


Author(s):  
Muhammad Fawad Rasool ◽  
Umbreen Fatima Qureshi ◽  
Nazar Muhammad Ranjha ◽  
Imran Imran ◽  
Mouqadus Un Nisa ◽  
...  

AbstractTh accurate rapid, simple and selective reversed phase high performance liquid chromatography (RP-HPLC) has been established and validated for the determination of captopril (CAP). Chromatographic separation was accomplished using prepacked ODSI C18 column (250 mm × 4.6 mm with 5 μm particle size) in isocratic mode, with mobile phase consisting of water: acetonitrile (60:40 v/v), pH adjusted to 2.5 by using 85% orthophosphoric acid at a flow rate of 1 mL/min and UV detection was performed at 203 nm. RP-HPLC method used for the analysis of CAP in mobile phase and rabbit plasma was established and validated as per ICH-guidelines. It was carried out on a well-defined chromatographic peak of CAP was established with a retention time of 4.9 min and tailing factor of 1.871. The liquid–liquid extraction method was used for extraction of CAP from the plasma. Excellent linearity (R2 = 0.999) was shown over range 3.125–100 µg/mL with mean percentage recoveries ranges from 97 to 100.6%. Parameters of precision and accuracy of the developed method meet the established criteria. Intra and inter-day precision (% relative standard deviation) study was also performed which was less than 2% which indicate good reproducibility of the method. The limit of detection (LOD) and quantification for the CAP in plasma were 3.10 and 9.13 ng/mL respectively. The method was suitably validated and successfully applied to the determination of CAP in rabbit plasma samples.


Author(s):  
Bijithra Cholaraja ◽  
Shanmugasundaram P ◽  
Ragan G ◽  
Sankar Ask ◽  
Sumithra M

ABSTRACTObjective: To development and validation of a reversed-phase high-performance liquid chromatography (RP-HPLC) for the determination of modafinilin bulk and pharmaceutical dosage forms.Methods: A simple, precise, rapid, and accurate RP-HPLC method was developed for the estimation of modafinil in bulk and pharmaceutical dosageforms. Xterra RP 18 (250 mm × 4.6 mm, 5 µ particle size) with a mobile phase consisting of methanol:water 70:30 V/V was used. The flow rate1.0 ml/min and the effluents were monitored at 260 nm. The retention time and recovery time was 12 minutes. The detector response was linear inthe concentration of 10-50 µg/ml. The respective linear regression equation being Y=452.1x+65237. The limit of detection and limit of quantificationwere 4.547 and 1.377 mcg, respectively. The method was validated by determining its accuracy, precision, and system suitability.Result: The objective of the present work is to develop simple, precise, and reliable HPLC method for the analysis of modafinil in bulk andpharmaceutical dosage forms. This is achieved using the most commonly employed Xterra RP 18 (250 mm × 4.6 mm, 5 μ particle size) columndetection at 260 nm. The present method was validated according to ICH guidelines.Conclusion: In this study, a simple, fast and reliable HPLC method was developed and validated for the determination of modafinil in pharmaceuticalformulations.Keywords: Modafinil, Reversed-phase high-performance liquid chromatography, Estimation, ICH guidelines, Tablets. 


Author(s):  
Geetha Susmita A ◽  
Rajitha G ◽  
Ramya Yadav Y ◽  
Uma P

Objective: The objective of this study was to develop and validate a stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of the metformin and empagliflozin in tablet dosage forms.Methods: The chromatographic conditions were optimized and it was run through Std. BDS (250 mm × 4.6 mm, 5 m) column with mobile phase consisting of 0.1% orthophosphoric acid buffer: acetonitrile in the ratio of 50:50. The flow rate was 1 ml/min and optimized wavelength was 210 nm. Temperature was maintained at 30°C.Results: The retention times of metformin and empagliflozin were found to be 2.588 min and 3.679 min and percentage relative standard deviation (RSD) of the metformin and empagliflozin was found to be 0.59 and 1.2, respectively. Percentage recovery was in the range of 100.01–100.65% for metformin and empagliflozin, respectively.Conclusion: A sensitive, rapid, and specific method has been developed for the simultaneous estimation of metformin and empagliflozin using RP-HPLC in tablet dosage form.


Author(s):  
Geetha Susmita A ◽  
Rajitha G ◽  
Ramya Yadav Y ◽  
Uma P

Objective: The objective of this study was to develop and validate a stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of the metformin and empagliflozin in tablet dosage forms.Methods: The chromatographic conditions were optimized and it was run through Std. BDS (250 mm × 4.6 mm, 5 m) column with mobile phase consisting of 0.1% orthophosphoric acid buffer: acetonitrile in the ratio of 50:50. The flow rate was 1 ml/min and optimized wavelength was 210 nm. Temperature was maintained at 30°C.Results: The retention times of metformin and empagliflozin were found to be 2.588 min and 3.679 min and percentage relative standard deviation (RSD) of the metformin and empagliflozin was found to be 0.59 and 1.2, respectively. Percentage recovery was in the range of 100.01–100.65% for metformin and empagliflozin, respectively.Conclusion: A sensitive, rapid, and specific method has been developed for the simultaneous estimation of metformin and empagliflozin using RP-HPLC in tablet dosage form.


Author(s):  
Vaishali Mistry ◽  
Akshay Yelwe ◽  
Amey Deshpande

Objective: The present study describes the stability indicating reversed-phase high-performance liquid chromatography (RP-HPLC) method for simultaneous estimation of 5-fluorouracil and tegafur in pharmaceutical dosage forms.Method: 5-fluorouracil and tegafur the propose RP-HPLC method were developed by using Shimadzu Prominence-i LC-2030 HPLC system equipped with UV detector and chromatographic separation was carried on shim-pack gist c18 (250 × 4.6 mm, 5 μ) column at a flow rate of 1 ml/min and the run time was 10 min. The mobile phase consisted of methanol and water in the ratio of 50:50% v/v and elements were scanned using a UV detector at 271 nm.Result: The retention time of 5-fluorouracil and tegafur was found to be 2.74 and 3.66 min, respectively. A linearity response was observed in the concentration range of 13.4 μg/ml–31.3 μg/ml for 5-fluorouracil and 6 μg/ml–14 μg/ml for tegafur, respectively. Limit of detection and limit of quantification of 5-fluorouracil were 10.97 μg/ml and 33.26 μg/ml and for tegafur are 4.89 μg/ml and 14.83 μg/ml, respectively.Conclusion: The stability indicating that the method was developed by subjecting drugs to stress conditions such as acid and base hydrolysis, oxidation, photo and thermal degradation, and degraded products formed were resolved successfully from samples.


Author(s):  
AWDHUT PIMPALE ◽  
RAJENDRA KAKDE

Objective: The present work was focused on the development and validation of reversed-phase high-performance liquid chromatography (RP-HPLC) method which is simple, rapid, precise, accurate, sensitive, economical, and stability-indicating for the quantification of rosuvastatin (RSV) calcium and clopidogrel bisulfate (CLO) in bulk and tablet formulation. Methods: The separation was attained on RP Princeton (C18) column with dimensions (250 mm × 4.6 mm, 5 μ) employing buffer which is a mixture of water (pH 3.0, adjusted with orthophosphoric acid), and methanol in the ratio (20:80) v/v as mobile phase, at flow rate 1.0 ml/min and detection was carried out at wavelength 240 nm. The retention time under the optimized condition of RSV calcium and CLO was found to be 2.844 min and 4.388 min, respectively. Results: The linearity of the method was demonstrated in the concentration range of 6–16 µg/ml and 45–120 µg/ml for RSV calcium and CLO with a correlation coefficient (r2) of 0.9999 and 0.9996, respectively. The percentage relative standard deviation was ˂2% and percentage recovery was found to be 100.12–101.37% and 99.72–101.09% for RSV calcium and CLO, respectively. Assay of marketed tablet formulation was found to be 98.99% and 99.92%, respectively. Conclusion: The developed RP-HPLC method was found to be simple, specific, sensitive, rapid, linear, accurate, precise, and economical and could be used for regular quality control of RSV calcium and CLO in bulk and tablet formulations.


Author(s):  
SUFIYAN AHMAD ◽  
PRANIT KHABIYA ◽  
TATIYA AU ◽  
ABDURL RAHEMAN BAKHSHI

Objective: As per requisition of current regulatory requirements, simple, rapid and sensitive method by 33 factorial quality by design approach was established and validated for Ambroxol (AMB) by reversed-phase high-performance liquid chromatography (RP-HPLC). Methods: A simple RP-HPLC method has been developed and validated with different parameters such as linearity, precision, repeatability, limit of detection (LOD), limit of quantitation (LOQ), accuracy as per International Conference for Harmonisation guidelines (Q2R1). Statistical data analysis was done for data obtained from different aliquots Runs on Agilent Tech. Gradient System with Auto injector, ultraviolet (UV) diode-array detection and Gradient Detector. Results: Equipped with Reverse Phase (Agilent) C18 column (4.6 mm × 100 mm; 2.5 μm), a 20 μl injection loop and UV730D Absorbance detector at 244 nm wave length and running chemstation 10.1 software and drugs along with degradants were separated via Methanol: (0.1% orthophosphoric acid) Water (75:25) of pH 3 as mobile phase setting flow rate 0.7 ml/min at ambient temperature the retention time of AMB were found to be 4.85 min. The industrialized method was found linear over the concentration range of 10–50 μg/ml for AMB while the LOD and LOQ of AMB was found to be 0.5174–0.2739 μg/ml, analytical method that concluded. Conclusion: There are no interfering peaks underperformed degradation conditions. Therefore, a sensitive, robust, accurate, and stability indicating method was developed with high degree of practical utility.


Sign in / Sign up

Export Citation Format

Share Document