scholarly journals Economic burden of lives lost due to COVID-19 in New York State

Author(s):  
Briana Lui ◽  
Michelle Zheng ◽  
Robert S White ◽  
Marguerite Hoyler

Aim: To examine the economic impact of lives lost due to the COVID-19 pandemic across New York State. Materials & methods: Death counts by age range and period life expectancy were extracted from the NYS Department of Health, NYC Department of Health and Mental Hygiene, and Social Security Administration website. Years of potential life lost and value of statistical life (VSL) were calculated. Results: The average years of potential life lost per person was 12.72 and 15.13, and the VSL was US$119.62 and 90.45 billion, in NYS and NYC, respectively. VSL was greatest in Queens and Brooklyn, followed by the Bronx, Manhattan and Staten Island. Conclusion: New York City, specifically Queens and Brooklyn, bore the greatest economic burden of lives lost across the state.

1927 ◽  
Vol 1 (3) ◽  
pp. 271-275
Author(s):  
Frederick W. Parsons

1989 ◽  
Vol 35 (10) ◽  
pp. 2059-2065 ◽  
Author(s):  
P J Parsons ◽  
N V Stanton ◽  
E W Gunter ◽  
D Huff ◽  
J R Meola ◽  
...  

Abstract This interlaboratory study was conducted to examine four erythrocyte protoporphyrin control materials from Aviv Biomedical, Helena Laboratories, Kaulson Laboratories, and the New York State Department of Health for use with hematofluorometers. Our principal aims were to monitor the stability of these materials at three different storage temperatures (room, refrigerator, freezer) and, where appropriate, to validate the manufacturer's target values. Measurements for the study were generated in three reference laboratories that used a total of five hematofluorometers, three from Environmental Science Associates and two from Aviv Biomedical. Each instrument was calibrated against a consensus acetic acid-ethyl acetate extraction procedure. We found the materials from Aviv to be the most stable, followed by the New York State material. However, the target values assigned by Aviv were not within the acceptable range determined by consensus. The target values assigned by Kaulson Laboratories for their materials did fall within the acceptable consensus range, but they were the least stable of the materials evaluated. The materials from Helena Laboratories were originally designed for use as calibrators with Helena's "ProtoFluor Z" hematofluorometer, which reports in different units. They were deemed unsuitable for use as control materials with the Aviv or Environmental Science Associates hematofluorometers because of the narrow range of values and the wide scatter of results.


1988 ◽  
Vol 2 (3) ◽  
pp. 174
Author(s):  
GERALDINE BUNN ◽  
MARY ELLEN HENRY ◽  
TODD GERBER

Sign in / Sign up

Export Citation Format

Share Document