scholarly journals Method Development and Validation of Gemifloxacin in Tablet Dosage Form by RP-HPLC

2020 ◽  
Vol 10 (4) ◽  
pp. 97-101
Author(s):  
Mithun Rudrapal ◽  
Nazim Hussain

A simple, precise and accurate RP-HPLC method was developed and validated for the estimation of gemifloxacin in the tablet dosage form. The separation was achieved on a reversed-phase C-18 column (250 x 4.6 mm i.d., 5 µm) using a mobile phase consisting of acetonitrile/acetate buffer of pH 4.5 (70:30 v/v) at a flow rate of 1.0 ml/min and a detection wavelength of 244 nm. The separation was carried out on an isocratic mode at room temperature. The method was validated as per ICH guidelines for linearity, accuracy, precision, robustness, LOD, LOQ and specificity. The developed method showed good linearity over the concentration range of 50-150 µg/ml (r2=0.995). The average percentage recovery was 99.77%. The LOD and LOQ were 12.678 µg/ml and 14.261 µg/ml, respectively. Based upon validation studies, the developed method can be successfully applied for the routine analysis of gemifloxacin in bulk drugs as well as pharmaceutical dosage forms. Keywords: Gemifloxacin, Tablet dosage form, RP-HPLC, Validation, ICH guidelines

2013 ◽  
Vol 49 (2) ◽  
pp. 359-366 ◽  
Author(s):  
Mustafa Çelebier ◽  
Tuba Reçber ◽  
Engin Koçak ◽  
Sacide Altinöz

Rivaroxaban, an anti-clotting medication, acts at a crucial point in the blood-clotting process and stops the formation of blood clots. In this study, RP-HPLC method was developed for the determination of rivaroxaban in tablets (Xarelto® (10 mg)). Phenomenex Luna 5 µm C18 100 Å LC Column (250 x 4.6 mm) was used at 40 ºC. Isocratic elution was performed with ACN:Water (55:45 v/v) mixture. The flow rate was 1.2 mL min-1 and UV detection was at 249 nm. Internal standard (Caffeine) and rivaroxaban were eluted within 2.21 and 3.37 minutes, respectively. The developed method was validated according to the ICH guidelines and found to be linear within the range 0.005 - 40.0 µg mL-1. The method was accurate, precise, robust and rapid. Thus, it was applied successfully for the quality control assay of rivaroxaban in tablet dosage form.


Author(s):  
Krishna Kishore Adireddy ◽  
Srinivasa Rao Baratam ◽  
Nagarjuna Hari Pratap S

A simple, rapid, accurate and precise RP-HPLC method was developed and validated for the determination of Istradefylline in table dosage form. Chromatographic analysis of the drug was achieved on Shimadzu HPLC comprising of LC- 20 AD binary gradient pump, a variable wavelength programmable SPD-20A detector and SCL system controller. C18G column (250 mm x 4.6 mm, 5 μ) as stationary phase with mobile phase consisting of 0.1 % orthophosphoric acid and acetonitrile in the ratio of 30: 70 v/v. The method showed a good linear response in the concentration range of 10-90 μg/ml with correlation coefficient of 0.9993. The flow rate was maintained at 1.0 ml/min and detection was carried out at 246 nm. The retention time was 3.125 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, solution stability, selectivity and sensitivity. The results obtained in the study were within the limits of ICH guidelines and hence this method can be used for the determination of istradefylline in tablet formulation.


INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (01) ◽  
pp. 58-61
Author(s):  
P. P Udapurkar ◽  
S. R. Kamble ◽  
K. R. Biyani ◽  

The present paper describes simple and sensitive, reversed phase high performance liquid chromatography (RP-HPLC) method developed for the determination of tapentadol hydrochloride in bulk and in its tablet dosage form. Chromatographic separation was achieved by using phenomenex C18 column, 250×4.6 mm, 5 μm as stationary phase. Mixture of acetonitrile: water (80:20 V/V) was used as the mobile phase and the pH was adjusted into 7.0 using orthophosphoric acid, at a flow rate of 0.7 mL/ min. Tapentadol standard shows maximum absorption in UV at 272 nm. The method was linear over the concentration range of 5-25 μg/mL. The method was validated statistically and recovery study was performed as per ICH guidelines. The analytical recovery obtained was 98-119%. As per validation data it was found that method is specific, robust and precise within the described concentration range. The described RP-HPLC method was successfully employed for the analysis of a commercial brand of tapentadol hydrochloride tablets.


2021 ◽  
Vol 2 (1) ◽  
pp. 015-022
Author(s):  
Gunasekar Manoharan ◽  
Bhargava Gottam

A simple and gradient RP- HPLC method has been validated and developed for Fluvastatin Sodium in bulk and tablet dosage form. The proposed method was validated to obtain official requirements including stability, accuracy, precision, linearity and selectivity. The method was developed on Hypersil ODS C18 column (150 x 4.6 mm, 5micron) using the mobile phase consists of methanol: 20mM Phosphate buffer (pH 3.2 adjusted with Phosphoric acid): acetonitrile (55: 30: 15 v/v) was delivered at a flow rate of. The flow rate was set as 1.1 ml/minute and the maximum absorption were observed at 234 nm. The Fluvastatin Sodium drug showed a precise and good linearity at the concentration ranges of 3-15 µg/ml. The RP-HPLC, assay showed the highest purity ranging 99.88 % to 100.09 % for Fluvastatin Sodium tablet formulation and 100.02 % was the mean percentage purity. The Fluvastatin Sodium retention time was found to be 5.5 minutes. The method accuracy was showed by statistical analysis. The developed RP-HPLC method can be adopted for the routine analysis of Fluvastatin Sodium in bulk and pharmaceutical dosage forms in quality control laboratories. The developed method was validated according to the ICH guidelines.


Author(s):  
Sireesha D ◽  
Sai Lakshmi E ◽  
Sravya E ◽  
Vasudha Bakshi

A new simple, rapid, specific, accurate, precise and novel Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method has been developed for the estimation of Sitagliptin Phosphate in the pharmaceutical dosage form. The chromatographic separation for Sitagliptin was achieved with mobile phase containing methanol, Thermoscientific C18 column, (250x4.6 particle size of 5μ) at room temperature and UV detection at 248 nm. The compounds were eluted in the isocratic mode at a flow rate of 1ml/min. The retention time of Sitagliptin was 1.91min. The above method was validated in terms of linearity, accuracy, precision, LOD and LOQ in accordance with ICH guidelines.


2019 ◽  
Vol 6 (1) ◽  
Author(s):  
Ananda Thangadurai Subramaniam ◽  
Devi Velmurugan ◽  
Sambathkumar Ramanathan ◽  
Kamalakannan Dhanabalan ◽  
Jambulingam Munusamy ◽  
...  

Recent study was conducted to develop and validate analytical methods for estimation of Risedronate sodium in pure and pharmaceutical dosage form using UV Spectroscopy and               RP- HPLC method. The first method (Method A) based on the UV Spectroscopy using 0.1M Hcl as diluent lambda max was found at 261 nm. Linearity existed perceived in the concentration between 10-50 μg/ml (r 2 = 0.999) for the method. The method was validated pertaining to linearity, precision and accuracy studies, LOD and LOQ consistent with ICH guidelines. The second method (Method B), based on determination of Risedronate sodium tablet dosage form by RP-HPLC method.  Chromatography separation was carried out on a C18 (150X4.6 mm x5 µ) SS Column using Methanol: Ammonium formate (85:15) as the mobile phase at a flow rate of   1.0 ml/min. The chromatographic analysis was carried out in the reflectance and absorbance mode at 254 nm and retention time of the drug was found to be 1.11 ml/min for standard and tablet. Linear responses of the drug were in the concentration range of 200-1000 µg/ml. The accuracy of the method was assessed by standard dilution method and found to be 98% to              102% .The results of the analysis were validated statistically prism software. The method established was found to be simple, precise, linear, accurate and sensitive. The developed method can be used for routine quality control analysis of Risedronate sodium in pure and pharmaceutical dosage form.


Author(s):  
D. Chinababu

Aim: The objective of the study was simplest, accurate, precise and robust reversed phase high performance liquid chromatographic (RP-HPLC) method was developed for the estimation of Velpatasvir (VEL) and Sofosbuvir (SOF) in the bulk and its tablet dosage form. Study Design: The Quantitative and Qualitative estimation and designed forced degradation study of Velpatasvir & Sofosbuvir by RP-HPLC. Place and Duration of Study: The study was carried at Santhiram College of Pharmacy and time taken 4 months. Method: The method was attained by used Waters( 5µm, C18 250 x 4.6 mm) column with mobile phase consists of  0.5 mM disodium hydrogen phosphate buffer pH adjusted to 6.5, with Orthophosphoric acid and Methanol in the ratio of 78:22 v/v, a flow rate of 1.0 mL/min and ultraviolet detection at 285 nm. Results: The method was validated as per ICH guidelines with different parameters, the mean retention times of VEL and SOF were found to be 2.8 & 4.7 min respectively. The resolution between VEL and SOF was found to be 10.66. The Correlation coefficients for calibration curves within the detection range of 32.5 - 97.5 and 125 - 375 µg/mL were 0.999 for VEL and SOF respectively. The LOD and LOQ for VEL and SOF were found to be 0.0068-0.029 µg/mL and 0.104-0.342 µg/mL respectively. Conclusion: The results were indicated that the developed method was used for the routine analysis of VEL & SOF combined form in bulk and its commercial formulation. To the best of our knowledge, there was no method of RP-HPLC for the determination of VEL alone or in combination with SOF molecule.


2020 ◽  
Vol 10 (6) ◽  
pp. 6610-6618

A Simple, selective, accurate, precise, linear, and stability-indicating RP-HPLC method was developed and validated for the estimation of Cinacalcet hydrochloride in bulk and tablet dosage forms. Chromatographic separation was achieved on X-Terra Symmetry C18 (4.6 x 150mm; 5 m) with mobile phase containing Phosphate buffer: Acetonitrile (40:60 v/v) pH adjusted to 3.0 ±0.05 with diluted ortho-phosphoric acid. The flow rate was maintained at 0.9 mL/min. The eluent was monitored at 282 nm. Moreover, the retention time of Cinacalcet was 2.8 minutes. The method was validated for linearity, accuracy, precision, and robustness as per ICH guidelines. The developed method was found linear between 25-150 μg/ml, and the linear regression coefficient was 0.999. The % RSD values are less than 2 % indicating the accuracy and precision of the method. The percentage of recovery was obtained from 98-102%. The system suitability parameters were found to be within the limit. Forced degradation studies were conducted under various conditions. The proposed method is simple, rapid, precise, and accurate. It can be used for the quantitation of Cinacalcet hydrochloride in bulk and commercial pharmaceutical dosage forms.


INDIAN DRUGS ◽  
2020 ◽  
Vol 57 (07) ◽  
pp. 47-51
Author(s):  
B. Anupama ◽  
P. Tejaswi ◽  
KNV. Chenchu Lakshmi ◽  
A. Vishwanadh

A rapid, simple and precise reversed phase high performance liquid chromatography (RP-HPLC) method was developed for the estimation of edoxabantosylate in tablets. The quantification was carried out using a Phenomenex C-18 column (250×4.6 mm i.d., 5µm particle size) in isocratic mode with mobile phase comprising of ammonium acetate buffer andacetonitrile in the ratio of 50:50 (V/V) at a flow rate 1 mL/min. The eluent was monitored at 240 nm. The retention time of the drug was 3.486 min. The calibration curve was linear in the concentration range of 5-25 µg/mL and per cent recovery ranged from 98.25-101.6.The developed method was validated as per ICH guidelines and the results obtained were satisfactory.The method can be applied for routine quality control analysis of edoxabantosylate in tablet dosage forms.