scholarly journals Microplastics in the drinking water of the Riobamba city, Ecuador

2019 ◽  
Vol 28 (4) ◽  
pp. 653-663 ◽  
Author(s):  
Marcel Paredes ◽  
Elba Bodero ◽  
Tito Castillo ◽  
Gabriela Fuentes ◽  
Rafaela Viteri

The city of Riobamba captures for human consumption groundwater from melting glaciers, from seven wells in the foothills of the Chimborazo volcano. The objective is determine the percentage of existing microplastics in drinking water distribution system. Sixty two samples were collected, analysed with a cellulose filter and Nile red dye. Then observed in a stereoscope, obtaining presence in 12 samples of the 62 analysed. The results of the analysis show that there is a 19% presence of microplastics.

2007 ◽  
Vol 5 (2) ◽  
pp. 219-227 ◽  
Author(s):  
S. M. September ◽  
F. A. Els ◽  
S. N. Venter ◽  
V. S. Brözel

Water for human consumption is required to be free from any bacteria that might pose a health risk. The presence of biofilms in the drinking water distribution system may play a role in the presence of potential pathogens in the drinking water supply. Ninety-five biofilm samples from various parts of South Africa were tested for the presence of Escherichia coli, Aeromonas, Pseudomonas, Salmonella, Shigella and Vibrio spp. Members of these genera were quantified by the three-tube most probable number (MPN) approach using enrichment broths and plating on selective agars. The heterotrophic culturable counts were determined for both the planktonic and biofilm phases of the samples. Biofilm density varied between 10 and 1.9 × 109 colony forming units cm−2. The 16S rRNA identity of the putative pathogenic isolates revealed that high numbers of Aeromonas, Pseudomonas,Klebsiella and Enterobacter were present, but no putative Salmonella and Shigella could be confirmed. None of the Pseudomonas isolates belonged to the pathogenic Pseudomonas aeruginosa or Pseudomonas mendocina while the Aeromonas isolates showed relatedness to known pathogenic members of this group.


2008 ◽  
Vol 8 (4) ◽  
pp. 421-426
Author(s):  
J. Menaia ◽  
M. Benoliel ◽  
A. Lopes ◽  
C. Neto ◽  
E. Ferreira ◽  
...  

Concerns arise from the possible occurrence of pathogens in drinking water pipe biofilms and storage tank sediments. In these studies, biofilm samples from pipes and sediments from storage tanks of the Lisbon drinking water distribution system were analyzed. Protein determinations and heterotrophic counts on pipe biofilm samples were used to assess the Lisbon network sessile colonization intensity and distribution. Indicator and pathogenic microorganisms were analyzed in pipe biofilm samples, as well as in storage tanks biofilm and sediments, by using cultural methods and PCR, to assess risks. Results have shown that the Lisbon network sessile colonization is relatively weak in intensity. In addition, no meaningful hazards were apparent for both the network biofilm and the storage tanks biofilm and sediments.


2009 ◽  
Vol 43 (20) ◽  
pp. 5005-5014 ◽  
Author(s):  
Jeffrey G. Szabo ◽  
Christopher A. Impellitteri ◽  
Shekar Govindaswamy ◽  
John S. Hall

2007 ◽  
Vol 2007 (1) ◽  
pp. 449-467
Author(s):  
Stacia L. Thompson ◽  
Elizabeth Casman ◽  
Paul Fischbeck ◽  
Mitchell J. Small ◽  
Jeanne M. VanBriesen

2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Nelly Molina Frechero ◽  
Leonor Sánchez Pérez ◽  
Enrique Castañeda Castaneira ◽  
Anastasio Oropeza Oropeza ◽  
Enrique Gaona ◽  
...  

Fluoride is ingested primarily through consuming drinking water. When drinking water contains fluoride concentrations >0.7 parts per million (ppm), consuming such water can be toxic to the human body; this toxicity is called “fluorosis.” Therefore, it is critical to determine the fluoride concentrations in drinking water. The objective of this study was to determine the fluoride concentration in the drinking water of the city of Durango. The wells that supply the drinking water distribution system for the city of Durango were studied. One hundred eighty-nine (189) water samples were analyzed, and the fluoride concentration in each sample was quantified as established by the law NMX-AA-077-SCFI-2001. The fluoride concentrations in such samples varied between 2.22 and 7.23 ppm with a 4.313 ± 1.318 ppm mean concentration. The highest values were observed in the northern area of the city, with a 5.001 ± 2.669 ppm mean value. The samples produced values that exceeded the national standard for fluoride in drinking water. Chronic exposure to fluoride at such concentrations produces harmful health effects, the first sign of which is dental fluorosis. Therefore, it is essential that the government authorities implement water defluoridation programs and take preventative measures to reduce the ingestion of this toxic halogen.


2009 ◽  
Vol 9 (1) ◽  
pp. 67-74 ◽  
Author(s):  
Elise Corbi ◽  
Valérie Jacquemet ◽  
Alain Quendo ◽  
Francine Manciot ◽  
Adeline Lamy ◽  
...  

Lyon, France has the opportunity to distribute in abundance a groundwater resource with a good quality for drinking water. However, the length and the complexity of the distribution network can lead to consumer complaints in some areas of the water distribution system. In order to improve the organoleptic quality of distributed water, the water supplier wants to get a better understanding of potential taste and odour formation and to succeed in controlling it. Since 2006, activities have been taken with targeted analyses and sensory evaluation of water, taking into account both the consumers' private networks and the citywide distribution network. The first results were focused on the occurrence of bromophenols along the water distribution system, the understanding of the mechanisms of formation of such compounds, as well as their incidence on taste-and-odour events at the consumer's home.


Sign in / Sign up

Export Citation Format

Share Document