scholarly journals Predictive values of resonance frequency analysis as a diagnostic tool in palatal implant loss

2019 ◽  
Vol 89 (5) ◽  
pp. 721-726
Author(s):  
Katja Wieczorek ◽  
Winfried Harzer ◽  
Heinrich Wehrbein ◽  
Maximilian Moergel ◽  
Martin Kunkel ◽  
...  

ABSTRACTObjectives:To determine the diagnostic value of resonance frequency analysis (RFA) in predicting palatal implant (PI) loss.Materials and Methods:RFA values of 32 patients (study center at Mainz and Dresden) were evaluated in a prospective randomized controlled trial addressing clinical performance of two loading concepts on PI (Orthosystem, Straumann, Basel, Switzerland). Group 1: conventional loading after a 12-week healing period vs group 2: immediate loading within one week after insertion. Stability was assessed by RFA after surgical insertion (T1), one week (T2), and 12 weeks (T3) later.Results:All 32 PI were clinically stable after surgical insertion; 14 PI were loaded conventionally and 18 immediately. One implant in group 1 was lost 6 weeks after insertion. One drop-out was registered in group 2. One false positive and three false negative implant stability quotients (ISQ) were observed. ISQ values of clinically stable PI in group 1 were 67.2 (SD ± 9.5) at T1, 62.3 (SD ± 11.7) at T2, and 68.2 (SD ± 5.5) at T3. Group 2 showed 67.1 (SD ± 11.7) at T1, 65.4 (SD ± 10.4) at T2, and 72.3 (SD ± 5.6) at T3. Differences between groups were not statistically significant for starting time (P = .88) and change from T1 to T2: 0.08 but were significant from T1 to T3: P = .04; (regression analysis).Conclusions:RFA had no sensitivity for prediction of stability. General decrease after primary stability and increase with secondary stability gives support for specificity. Within the limits of the study, only the diagnostic value of RFA identifying stable palatal implants could be confirmed.

2015 ◽  
Vol 41 (6) ◽  
pp. e281-e286 ◽  
Author(s):  
Sergio Alexandre Gehrke ◽  
Ulisses Tavares da Silva ◽  
Massimo Del Fabbro

The purpose of this study was to assess implant stability in relation to implant design (conical vs. semiconical and wide-pitch vs narrow-pitch) using resonance frequency analysis. Twenty patients with bilateral edentulous maxillary premolar region were selected. In one hemiarch, conical implants with wide pitch (group 1) were installed; in the other hemiarch, semiconical implants with narrow pitch were installed (group 2). The implant allocation was randomized. The implant stability quotient (ISQ) was measured by resonance frequency analysis immediately following implant placement to assess primary stability (time 1) and at 90 days after placement (time 2). In group 1, the mean and standard deviation ISQ for time 1 was 65.8 ± 6.22 (95% confidence interval [CI], 55 to 80), and for time 2, it was 68.0 ± 5.52 (95% CI, 57 to 77). In group 2, the mean and standard deviation ISQ was 63.6 ± 5.95 (95% CI, 52 to 78) for time 1 and 67.0 ± 5.71 (95% CI, 58 to 78) for time 2. The statistical analysis demonstrated significant difference in the ISQ values between groups at time 1 (P = .007) and no statistical difference at time 2 (P = .54). The greater primary stability of conical implants with wide pitch compared with semiconical implants with narrow pitch might suggest a preference for the former in case of the adoption of immediate or early loading protocols.


2018 ◽  
Vol 8 ◽  
pp. 139-145
Author(s):  
Ashish Kumar Singh ◽  
Sridhar Kannan ◽  
Nitin Arora ◽  
Yatin Bajaj ◽  
Ameet V. Revankar

Introduction In the last decade, anchorage control with mini-implants has gained enormous credibility in maintaining orthodontic anchorage. Resonance frequency analysis (RFA) has proven to be an adequate method to measure the stability of these mini-implants because of its non-invasiveness and contactless measurement method. Materials and Method Tomas and S.K surgical mini-implants were tested. For this purpose custom fabricated attachment was fabricated to attach the smart peg on orthodontic mini-implant head, and 45 mini-implants were inserted in fresh swine pelvic bone in the density matched sites to that of most common sites where mini-implants are placed in human mandible. Mini-implants of two different lengths with diameter constant were also placed to assess the effect of length on primary stability. Results The mean ISQ of Group 1 (Tomas 10 mm) was 55.53±3.39 while that of Group 2 (S.K Surgical 10mm) was 56.63±3.48 and that of Group 3(S.K Surgical 8 mm) was 55.90±3.48. Difference among the groups were not statistically significant when ANOVA test was used (P >0.05). Conclusion The resonance frequency analysis is applicable to comparatively assess the primary stability of orthodontic mini-implants. There was no difference in primary stability of Tomas and S.K Surgical mini-implant and primary stability was not affected by the length of the mini-implant.


Author(s):  
ÇAĞLAR BİLMENOĞLU BİLMENOĞLU ◽  
ANIL ÖZYURT ◽  
AHMET ALTUĞ ÇİLİNGİR ◽  
FATMA NESRİN TURAN

The aim of this study was to examine the primary stabilization of different vertically impacted bone implants. Implant stability was measured by resonance frequency analysis. Forty-five dental implants were used and divided into three groups. Group 1 was placed 4 mm (1/3 impacted), Group 2 was placed 8 mm (2/3 impacted), and Group 3 was placed 12 mm (fully impacted). Implant stability quotient values were measured on the longitudinal and transversal axis by two independent researchers. The fully-impacted group showed the significantly highest value among the groups (p < 0.05). There were statistically varying implant-stability quotient values between researchers. None of the 1/3 impacted implants’ value reached a 70 implant-stability quotient value.


2020 ◽  
Vol 46 (3) ◽  
pp. 182-189 ◽  
Author(s):  
Davide Farronato ◽  
Mattia Manfredini ◽  
Michele Stocchero ◽  
Mattia Caccia ◽  
Lorenzo Azzi ◽  
...  

The aim of this study was to evaluate the influence of bone quality, drilling technique, implant diameter, and implant length on insertion torque (IT) and resonance frequency analysis (RFA) of a prototype-tapered implant with knife-edge threads. The investigators hypothesized that IT would be affected by variations in bone quality and drilling protocol, whereas RFA would be less influenced by such variables. The investigators implemented an in vitro experiment in which a prototype implant was inserted with different testing conditions into rigid polyurethane foam blocks. The independent variables were: bone quality, drilling protocol, implant diameter, and implant length. Group A implants were inserted with a conventional drilling protocol, whereas Group B implants were inserted with an undersized drilling protocol. Values of IT and RFA were measured at implant installation. IT and RFA values were significantly correlated (Pearson correlation coefficient: 0.54). A multivariable analysis showed a strong model. Higher IT values were associated with drilling protocol B vs A (mean difference: 71.7 Ncm), implant length (3.6 Ncm increase per mm in length), and substrate density (0.199 Ncm increase per mg/cm3 in density). Higher RFA values were associated with drilling protocol B vs A (mean difference: 3.9), implant length (1.0 increase per mm in length), and substrate density (0.032 increase per mg/cm3 in density). Implant diameter was not associated with RFA or IT. Within the limitations of an in vitro study, the results of this study suggest that the studied implant can achieve good level of primary stability in terms of IT and RFA. A strong correlation was found between values of IT and RFA. Both parameters are influenced by the drilling protocol, implant length, and substrate density. Further studies are required to investigate the clinical response in primary stability and marginal bone response.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Bada Choi ◽  
Ye Chan Lee ◽  
Kyung Chul Oh ◽  
Jae Hoon Lee

Abstract Background This study aimed to investigate the effects of ultraviolet (UV) photofunctionalization on the stability of implants during the early phase in the posterior region of the maxilla. The study was a randomized double-blinded clinical trial. Half of the participants received conventional commercial implants while the other half received UV-irradiated implants. The surgical sites were classified into three bone quality groups (II, III, IV) based on the grayscale value measured on cone-beam computed tomography. The values obtained from resonance frequency analysis were recorded immediately after implant placement and at 4 weeks and at 4 months postoperatively. The marginal bone level of the implants was evaluated using periapical radiographs at 4 weeks, 4 months, and 1 year postoperatively. Results Fifty-seven implants placed in 34 participants were analyzed in this study. In group III, significant differences were observed in terms of the differences of resonance frequency analysis values at 4 weeks (p = 0.004) and 4 months (p = 0.017) postoperatively. In group II, the UV-treated group showed significantly lesser bone loss at 4 weeks post-operatively (p = 0.037). Conclusions Within the limitation of the present study, we concluded that UV surface treatment on implants may increase the initial stability in the region of the maxilla with poor bone quality.


Author(s):  
Ingrid Kästel ◽  
Giles de Quincey ◽  
Jörg Neugebauer ◽  
Robert Sader ◽  
Peter Gehrke

Abstract Background There is disagreement about the optimal torque for tightening smartpegs for resonance frequency analysis (RFA). Subjective finger pressure during hand tightening could affect the reliability of the resulting values. The aim of the current study was therefore to assess whether or not the insertion torque of a smartpeg magnetic device influences the implant stability quotient (ISQ) value during RFA. Methods Thirty self-tapping screw implants (XiVE S, Dentsply Sirona Implants, Bensheim, Germany) with a diameter of 3.8 mm and a length of 11 mm were inserted in three cow ribs with a bone quality of D1. The RFA value of each implant was measured (Ostell, FA W&H Dentalwerk, Bürmoos, Austria) in two orthogonal directions (mesial and buccal) after tightening the corresponding smartpeg type 45 with a mechanically defined value of 5 Ncm (Meg Torq device, Megagen, Daegu, South Korea) (test). Additionally, 4 different examiners measured the RFA after hand tightening the smartpegs, and the results were compared (control). Insertion torque values were determined by measuring the unscrew torque of hand seated smartpegs (Tohnichi Manufacturing Co. Ltd, Tokyo, Japan). Results The ISQ values varied from 2 to 11 Ncm by hand tightening and from 2 to 6 Ncm by machine tightening. The comparison of hand and machine tightening of smartpegs displayed only minor differences in the mean ISQ values with low standard deviations (mesial 79.76 ± 2,11, buccal 77.98 ± 2,) and no statistical difference (mesial p = 0,343 and buccal p = 0,890). Conclusions Manual tightening of smartpeg transducers allows for an objective and reliable determination of ISQ values during RFA.


2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Michael Cordes ◽  
Theresa Ida Götz ◽  
Elmar Wolfgang Lang ◽  
Stephan Coerper ◽  
Torsten Kuwert ◽  
...  

Abstract Background Ultrasound is the first-line imaging modality for detection and classification of thyroid nodules. Certain characteristics observable by ultrasound have recently been identified that may indicate malignancy. This retrospective cohort study was conducted to test the hypothesis that advanced thyroid carcinomas show distinctive clinical and sonographic characteristics. Using a neural network model as proof of concept, nine clinical/sonographic features served as input. Methods All 96 study enrollees had histologically confirmed thyroid carcinomas, categorized (n = 32, each) as follows: group 1, advanced carcinoma (ADV) marked by local invasion or distant metastasis; group 2, non-advanced papillary carcinoma (PTC); or group 3, non-advanced follicular carcinoma (FTC). Preoperative ultrasound profiles were obtained via standardized protocols. The neural network had nine input neurons and one hidden layer. Results Mean age and the number of male patients in group 1 were significantly higher compared with groups 2 (p = 0.005) or 3 (p <  0.001). On ultrasound, tumors of larger volume and irregular shape were observed significantly more often in group 1 compared with groups 2 (p <  0.001) or 3 (p ≤ 0.01). Network accuracy in discriminating advanced vs. non-advanced tumors was 84.4% (95% confidence interval [CI]: 75.5–91), with positive and negative predictive values of 87.1% (95% CI: 70.2–96.4) and 92.3% (95% CI: 83.0–97.5), respectively. Conclusions Our study has shown some evidence that advanced thyroid tumors demonstrate distinctive clinical and sonographic characteristics. Further prospective investigations with larger numbers of patients and multicenter design should be carried out to show whether a neural network incorporating these features may be an asset, helping to classify malignancies of the thyroid gland.