Effect of Er,Cr: YSGG Laser on the Microtensile Bond Strength of Two Different Adhesives to the Sound and Caries-affected Dentin

2009 ◽  
Vol 34 (4) ◽  
pp. 460-466 ◽  
Author(s):  
Z. Ergücü ◽  
E. U. Çelik ◽  
N. Ünlü ◽  
M. Türkün ◽  
F. Özer

Clinical Relevance The microtensile bond strength of a three-step etch-and-rinse and a two-step self-etch adhesive is not negatively affected by Er,Cr:YSGG laser irradiation in sound and caries-affected dentin.

2010 ◽  
Vol 35 (4) ◽  
pp. 428-435 ◽  
Author(s):  
A. Reis ◽  
C. Zander-Grande ◽  
S. Kossatz ◽  
R. Stanislawczuk ◽  
A. Manso ◽  
...  

Clinical Relevance All Bond 3 and All Bond Self-Etch are versatile systems, capable of being used either in the full or simplified version. Both showed adequate microtensile bond strength results in enamel and dentin after 24 hours of water storage.


2009 ◽  
Vol 34 (3) ◽  
pp. 328-336 ◽  
Author(s):  
C. D'Arcangelo ◽  
F. De Angelis ◽  
M. D'Amario ◽  
S. Zazzeroni ◽  
C. Ciampoli ◽  
...  

Clinical Relevance Compared to self-etch and self-adhesive luting systems, the two etch-and-rinse luting agents evaluated in the current study provided more reliable bonding when used to bond indirect resin-based composite restorations to sound dentin. On the contrary, the self-adhesive luting system showed the highest mean bond strength for the cementation of glass ceramic restorations.


2008 ◽  
Vol 33 (4) ◽  
pp. 448-455 ◽  
Author(s):  
M. V. Cardoso ◽  
J. De Munck ◽  
E. Coutinho ◽  
R. B. Ermis ◽  
K. Van Landuyt ◽  
...  

Clinical Relevance Er,Cr:YSGG laser irradiation produced morphological alterations on enamel, which may adversely influence the bond strength of certain adhesives, depending on their approach and composition.


Marine Drugs ◽  
2020 ◽  
Vol 18 (5) ◽  
pp. 263 ◽  
Author(s):  
Eugenia Baena ◽  
Sandra R Cunha ◽  
Tatjana Maravić ◽  
Allegra Comba ◽  
Federica Paganelli ◽  
...  

The aim of the present study was to evaluate the effect of 0.1% chitosan (Ch) solution as an additional primer on the mechanical durability and enzymatic activity on dentine using an etch-and-rinse (E&R) adhesive and a universal self-etch (SE) adhesive. Microtensile bond strength and interfacial nanoleakage expression of the bonded interfaces for all adhesives (with or without pretreatment with 0.1% Ch solution for 1 min and air-dried for 5 s) were analyzed immediately and after 10,000 thermocycles. Zymograms of protein extracts from human dentine powder incubated with Optibond FL and Scotchbond Universal on untreated or Ch-treated dentine were obtained to examine dentine matrix metalloproteinase (MMP) activities. The use of 0.1% Ch solution as an additional primer in conjunction with the E&R or SE adhesive did not appear to have influenced the immediate bond strength (T0) or bond strength after thermocycling (T1). Zymography showed a reduction in MMP activities only for mineralized and demineralized dentine powder after the application of Ch. Application of 0.1% Ch solution does not increase the longevity of resin–dentine bonds. Nonetheless, the procedure appears to be proficient in reducing dentine MMP activities within groups without adhesive treatments. Further studies are required to comprehend the cross-linking of Ch with dentine collagen.


2010 ◽  
Vol 35 (1) ◽  
pp. 94-104 ◽  
Author(s):  
M. Sarr ◽  
A. W. Kane ◽  
J. Vreven ◽  
A. Mine ◽  
K. L. Van Landuyt ◽  
...  

Clinical Relevance In the current study, contemporary adhesives are assessed mechanically and ultra-morphologically to predict clinical effectiveness. Adhesives with simplified application procedures (in particular, one-step self-etch adhesives) still underperform as compared to conventional “gold-standard” multi-step adhesives. “Mild” two-step self-etch adhesives that provide additional chemical bonding appear to most optimally combine bonding effectiveness with a simplified application protocol.


2017 ◽  
Vol 41 (3) ◽  
pp. 214-218 ◽  
Author(s):  
Tathiane Larissa Lenzi ◽  
Fabio Zovico Maxnuck Soares ◽  
Rachel de Oliveira Rocha

Objective: To evaluate the effect of bonding strategy on microtensile bond strength (μTBS) of a new universal adhesive system to primary tooth dentin. Study design: Flat dentin surfaces from 25 primary molars were assigned to 5 groups according to the adhesive and bonding approach: Adper Single Bond 2 (two-step etch-and-rinse adhesive) and Clearfil SE Bond (two-step self-etch system), as controls; Scotchbond Universal Adhesive–self-etch, dry or wet-bonding etch-and-rinse strategies. Composite buildups were constructed and the teeth were sectioned to obtain bonded sticks (0.8 mm2) to be tested under tension at 1mm/min. The μTBS means were analyzed by one-way ANOVA and Tukey's tests (α = 0.05). Failure mode was evaluated using a stereomicroscope (400×). Results: Universal adhesive applied following both dry and wet-bonding etch-and-rinse strategies showed similar bond strength compared with control adhesive systems. Self-etch approach resulted in the lowest μTBS values. For all groups, adhesive/mixed failure prevailed. The percentage of premature debonded specimens was higher when the universal adhesive was used as self-etch mode. Conclusion: The universal adhesive does not share the same versatility of being used in the etch-and-rinse and self-etch approaches; however, the use of the new adhesive following either wet or dry-bonding may be a suitable option as alternative to two-step etch-and-rinse adhesive protocol.


10.2341/05-38 ◽  
2006 ◽  
Vol 31 (3) ◽  
pp. 332-337 ◽  
Author(s):  
W. W. Brackett ◽  
S. Ito ◽  
Y. Nishitani ◽  
L. D. Haisch ◽  
D. H. Pashley

Clinical Relevance Bond strength to ground enamel of single component self-etching adhesive systems was lower than that of etch-and-rinse and self-etching primer systems.


2012 ◽  
Vol 37 (6) ◽  
pp. 610-616 ◽  
Author(s):  
RL Quock ◽  
JA Barros ◽  
SW Yang ◽  
SA Patel

SUMMARY The aim of this in vitro study was to investigate the effect of the cariostatic and preventive agent silver diamine fluoride (SDF) on the microtensile bond strength of resin composite to dentin. Forty-two caries-free, extracted molars were flattened occlusally and apically using a diamond saw, and the exposed occlusal dentin was polished with a series of silicon carbide papers, all under water irrigation. The teeth were then randomly divided into six groups of seven teeth each that were treated as follows: 1) Peak SE self-etch bonding agent; 2) 12% SDF + Peak SE; 3) 38% SDF + Peak SE; 4) Peak LC etch-and-rinse bonding agent; 5) 12% SDF + Peak LC; and 6) 38% SDF + Peak LC. Four-millimeter buildups of Amelogen Plus were incrementally placed on all teeth; after a 24-hour storage period in distilled water, the specimens were sectioned perpendicular to the adhesive interface to produce beams of cross-sectional surface area measuring approximately 1 mm2. The beams were placed on a microtensile testing machine, which utilized a single-speed pump motor and force gauge at 20 kgf × 0.01 second to record maximum tensile force before failure occurred. Two-way analysis of variance and post hoc Tukey tests were performed to compare the effects of the SDF on microtensile bond strength, with statistical significance set at α = 0.05. None of the experimental groups treated with different concentrations of SDF showed a significant difference in bond strength compared to the control groups, and there was no significant difference in bond strength between self-etch and etch-and-rinse groups. However, the effect of SDF on self-etch bonded teeth compared to etch-and-rinse bonded teeth was statistically significant (p=0.0363), specifically at the 12% concentration. SDF does not adversely affect the bond strength of resin composite to noncarious dentin.


2006 ◽  
Vol 85 (12) ◽  
pp. 1092-1096 ◽  
Author(s):  
L. Breschi ◽  
A. Mazzoni ◽  
D.H. Pashley ◽  
G. Pasquantonio ◽  
A. Ruggeri ◽  
...  

The use of electric current during the application of etch-and-rinse adhesive systems has been recently claimed to increase bonding of etch-and-rinse adhesives by enhancing substrate impregnation. The null hypothesis tested in this study was that electrically assisted application has no effect on bond strength of self-etching bonding systems. Three self-etch adhesives (Protect-Bond, Xeno III, and Prompt L-Pop) were applied with the aid of an electric signal-generating device (ElectroBond) and tested vs. controls prepared with the same disposable sponges but without electric current. Specimens bonded under the influence of electric current exhibited increased microtensile bond strength compared with the controls (p < 0.05). High-resolution SEM analysis showed that bonding under the influence of electricity reduced interfacial nanoleakage. It is speculated that resin infiltration may be improved by the attraction of polar monomers by an electric current or by modification of the dentin surface charges, resulting in better water substitution or evaporation.


Sign in / Sign up

Export Citation Format

Share Document