The Influence of Luting Systems on the Microtensile Bond Strength of Dentin to Indirect Resin-based Composite and Ceramic Restorations

2009 ◽  
Vol 34 (3) ◽  
pp. 328-336 ◽  
Author(s):  
C. D'Arcangelo ◽  
F. De Angelis ◽  
M. D'Amario ◽  
S. Zazzeroni ◽  
C. Ciampoli ◽  
...  

Clinical Relevance Compared to self-etch and self-adhesive luting systems, the two etch-and-rinse luting agents evaluated in the current study provided more reliable bonding when used to bond indirect resin-based composite restorations to sound dentin. On the contrary, the self-adhesive luting system showed the highest mean bond strength for the cementation of glass ceramic restorations.

2010 ◽  
Vol 35 (4) ◽  
pp. 428-435 ◽  
Author(s):  
A. Reis ◽  
C. Zander-Grande ◽  
S. Kossatz ◽  
R. Stanislawczuk ◽  
A. Manso ◽  
...  

Clinical Relevance All Bond 3 and All Bond Self-Etch are versatile systems, capable of being used either in the full or simplified version. Both showed adequate microtensile bond strength results in enamel and dentin after 24 hours of water storage.


2016 ◽  
Vol 10 (1) ◽  
pp. 268-277 ◽  
Author(s):  
Fernanda Borguetti Manfroi ◽  
Maurem Leitão Marcondes ◽  
Deise Caren Somacal ◽  
Gilberto Antonio Borges ◽  
Luiz Henrique Burnett Júnior ◽  
...  

Objective: The aim of the study was to evaluate the microtensile bond strength (µTBS) of Scotchbond Universal to dentin using the etch-and-rinse or the self-etch technique after 24 h and 6 months of storage. Materials and Methods: Flat dentin surfaces were obtained in 24 third molars. The teeth were divided into four groups: G1 – Scotchbond Universal applied in the etch-and-rinse mode; G2 – Scotchbond Universal applied in the self-etch mode; G3 – Scotchbond Multi-Purpose; G4 – Clearfil SE Bond. A block of composite was built on the adhesive area. The tooth/resin sets were cut parallel to the long axis to obtain 40 beams (~0.8 mm2) for each group. Twenty specimens were immediately submitted to the µTBS test, and the remaining 20 were stored in water for 6 months. Failures and the adhesive interface were analyzed by SEM. Results: According to two-way ANOVA, the interaction between adhesive and storage time was significant (p=0.015).The µTBS (MPa) means were the following: 24 h – G1 (39.37±10.82), G2 (31.02±13.76), G3 (35.09±14.03) and G4 (35.84±11.06); 6 months – G1 (36.99±8.78), G2 (40.58±8.07), G3 (32.44±6.07) and G4 (41.75±8.25). Most failures were mixed. Evidence of hybrid layer and numerous resin tags were noted for Scotchbond Universal applied with the etch-and-rinse mode and Scotchbond Multi-Purpose. A thinner hybrid layer and fewer resin tags were noted for Scotchbond Universal applied in the self-etch mode and Clearfil SE Bond. Conclusion: The results indicate that the µTBS for Scotchbond Universal is comparable to the gold-standard adhesives. Scotchbond Universal applied in the self-etch mode and Clearfil SE Bond revealed higher bond stability compared to the etch-and-rinse mode.


2009 ◽  
Vol 34 (4) ◽  
pp. 460-466 ◽  
Author(s):  
Z. Ergücü ◽  
E. U. Çelik ◽  
N. Ünlü ◽  
M. Türkün ◽  
F. Özer

Clinical Relevance The microtensile bond strength of a three-step etch-and-rinse and a two-step self-etch adhesive is not negatively affected by Er,Cr:YSGG laser irradiation in sound and caries-affected dentin.


10.2341/07-42 ◽  
2008 ◽  
Vol 33 (1) ◽  
pp. 79-88 ◽  
Author(s):  
A. D. Loguercio ◽  
S. K. Moura ◽  
A. Pellizzaro ◽  
K. Dal-Bianco ◽  
R. T. Patzlaff ◽  
...  

Clinical Relevance The effect of surface preparation was adhesive-dependent. Improvements in resin-enamel bond strength after enamel preparation were observed only for AdheSE and Optibond Solo plus Self-Etch Primer. Among the self-etch systems, mild, self-etch Clearfil SE Bond showed the highest bond strength values. No degradation of resin-enamel bonds was observed after 12 months of water storage, regardless of the adhesive tested.


Marine Drugs ◽  
2020 ◽  
Vol 18 (5) ◽  
pp. 263 ◽  
Author(s):  
Eugenia Baena ◽  
Sandra R Cunha ◽  
Tatjana Maravić ◽  
Allegra Comba ◽  
Federica Paganelli ◽  
...  

The aim of the present study was to evaluate the effect of 0.1% chitosan (Ch) solution as an additional primer on the mechanical durability and enzymatic activity on dentine using an etch-and-rinse (E&R) adhesive and a universal self-etch (SE) adhesive. Microtensile bond strength and interfacial nanoleakage expression of the bonded interfaces for all adhesives (with or without pretreatment with 0.1% Ch solution for 1 min and air-dried for 5 s) were analyzed immediately and after 10,000 thermocycles. Zymograms of protein extracts from human dentine powder incubated with Optibond FL and Scotchbond Universal on untreated or Ch-treated dentine were obtained to examine dentine matrix metalloproteinase (MMP) activities. The use of 0.1% Ch solution as an additional primer in conjunction with the E&R or SE adhesive did not appear to have influenced the immediate bond strength (T0) or bond strength after thermocycling (T1). Zymography showed a reduction in MMP activities only for mineralized and demineralized dentine powder after the application of Ch. Application of 0.1% Ch solution does not increase the longevity of resin–dentine bonds. Nonetheless, the procedure appears to be proficient in reducing dentine MMP activities within groups without adhesive treatments. Further studies are required to comprehend the cross-linking of Ch with dentine collagen.


2009 ◽  
Vol 102 (5) ◽  
pp. 306-312 ◽  
Author(s):  
Ronaldo G. Viotti ◽  
Alline Kasaz ◽  
Carlos E. Pena ◽  
Rodrigo S. Alexandre ◽  
Cesar A. Arrais ◽  
...  

2019 ◽  
Vol 30 (5) ◽  
pp. 467-475 ◽  
Author(s):  
Gabriela Cardoso de Cardoso ◽  
Leina Nakanishi ◽  
Cristina Pereira Isolan ◽  
Patrícia dos Santos Jardim ◽  
Rafael Ratto de Moraes

Abstract This study evaluated the immediate and 6-month dentin bond strength of universal adhesives used in etch-and-rinse or self-etch bonding strategies. The adhesives tested were Ambar Universal, G-Bond, Single Bond Universal, Tetric N-Bond Universal, and Ybond Universal. Gold standard adhesives (Scotchbond Multipurpose Plus and Clearfil SE Bond) were controls. Microtensile dentin bond strength (n=5 teeth), pH, and C=C conversion (n=3) were evaluated. Data were analyzed at α=0.05. All adhesives showed differences in pH. Ybond had intermediately strong aggressiveness, whereas the others were ultra-mild. The C=C conversion was different in most adhesives. In the etch-and-rinse strategy, all adhesives showed similar results generally except for G-Bond, which had lower bond strength than most adhesives. G-Bond and Tetric-N-Bond showed lower bond strengths after 6 months compared with 24 h, whereas the other adhesives had stable dentin bonds. In the self-etch strategy, G-Bond had lower bond strength than most adhesives. After 6 months, Ambar was the only adhesive showing lower dentin bond strength compared with 24 h. Most adhesives had discreet drops in bond strength during aging when used in the self-etch strategy. The failure modes were also material dependent, with a general pattern of increased adhesive and/or pre-testing failures after storage. In conclusion, the bonding performance of universal adhesives to dentin is material dependent. Most adhesives had stable dentin bonds with results comparable to the gold standard materials, particularly when applied in the self-etch mode. In general, it seems the use of universal adhesives in dentin should not be preceded by phosphoric acid etching.


2010 ◽  
Vol 35 (1) ◽  
pp. 94-104 ◽  
Author(s):  
M. Sarr ◽  
A. W. Kane ◽  
J. Vreven ◽  
A. Mine ◽  
K. L. Van Landuyt ◽  
...  

Clinical Relevance In the current study, contemporary adhesives are assessed mechanically and ultra-morphologically to predict clinical effectiveness. Adhesives with simplified application procedures (in particular, one-step self-etch adhesives) still underperform as compared to conventional “gold-standard” multi-step adhesives. “Mild” two-step self-etch adhesives that provide additional chemical bonding appear to most optimally combine bonding effectiveness with a simplified application protocol.


2017 ◽  
Vol 41 (3) ◽  
pp. 214-218 ◽  
Author(s):  
Tathiane Larissa Lenzi ◽  
Fabio Zovico Maxnuck Soares ◽  
Rachel de Oliveira Rocha

Objective: To evaluate the effect of bonding strategy on microtensile bond strength (μTBS) of a new universal adhesive system to primary tooth dentin. Study design: Flat dentin surfaces from 25 primary molars were assigned to 5 groups according to the adhesive and bonding approach: Adper Single Bond 2 (two-step etch-and-rinse adhesive) and Clearfil SE Bond (two-step self-etch system), as controls; Scotchbond Universal Adhesive–self-etch, dry or wet-bonding etch-and-rinse strategies. Composite buildups were constructed and the teeth were sectioned to obtain bonded sticks (0.8 mm2) to be tested under tension at 1mm/min. The μTBS means were analyzed by one-way ANOVA and Tukey's tests (α = 0.05). Failure mode was evaluated using a stereomicroscope (400×). Results: Universal adhesive applied following both dry and wet-bonding etch-and-rinse strategies showed similar bond strength compared with control adhesive systems. Self-etch approach resulted in the lowest μTBS values. For all groups, adhesive/mixed failure prevailed. The percentage of premature debonded specimens was higher when the universal adhesive was used as self-etch mode. Conclusion: The universal adhesive does not share the same versatility of being used in the etch-and-rinse and self-etch approaches; however, the use of the new adhesive following either wet or dry-bonding may be a suitable option as alternative to two-step etch-and-rinse adhesive protocol.


Sign in / Sign up