scholarly journals Use of Measurement Uncertainty in Compliance Assessment in Custody Transfer Operations

2021 ◽  
Vol 5 (4) ◽  
pp. 1-2
Author(s):  
Oliveira EC
2015 ◽  
Vol 7 (5) ◽  
pp. 2219-2228
Author(s):  
M. João Nunes ◽  
M. João de Moura

In house validation using several different fertilizer types and two analytical methods for total nitrogen content determination with assessment of measurement uncertainty. Importance of decision of analytical methods and rules for compliance assessment.


Author(s):  
Salvatore Sgrò ◽  
Benedicta Lavezzi ◽  
Cristian Caprari ◽  
Marco Polito ◽  
Marcello D’Elia ◽  
...  

AbstractHemp cultivation is living a period of renewed interest worldwide after long years of opposition and abandonment. The European Union (EU) allows and subsidizes the growing of fiber and oilseed cultivars of Cannabis sativa L. with respect to the THC content limit of 0.2%. The EU method for the quantitative determination of Δ9-tetrahydrocannabinol (THC) content in hemp varieties provides to apply a tolerance of 0.03 g of THC per 100 g of sample concerning compliance assessment to that limit. However, the method does not report any precision data, especially useful as a function of THC content to evaluate measurement uncertainty and therefore to establish the conformity of hemp at different THC legal limits. Measurement uncertainty of the method by both bottom-up and top-down approach, besides repeatability and reproducibility, was investigated and estimated in the THC concentration range 0.2–1.0%, which includes the different legal limits set out for hemp around the world. We proposed Decision Rules for conformity of hemp showing that a non-compliant declaration beyond reasonable doubt should be stated when the THC content, as a mean result on a duplicate analysis, exceeds the limit by at least 11–15%, depending on THC limit. We highlighted other issues concerning practical aspects of hemp analysis, from sampling to evaluation of results, as well as the need to carry out collaborative studies on the EU method. Graphical abstract


2020 ◽  
pp. 6-10
Author(s):  
A.E. Aslanyan ◽  
E.G. Aslanyan ◽  
S.M. Gavrilkin ◽  
A.S. Doynikov ◽  
A.N. Shchipunov

The article presents the results of studies to improve the National primary standard machine for hardness of metals on the shore D scale GET 161-2001, which were performed in FSUE “VNIIFTRI” from 2016 to 2018 in accordance with the technical task of Rosstandart.The improvement was carried out in order to ensure the uniformity of hardness measurements on the Leeb scales. The created new parts of the primary standard machine, which are settings for reproducing hardness numbers on the Leeb scales, are considered. Metrological characteristics of the upgraded and adopted National primary standard machine (GET 161-2019) were investigated, the budget of measurement uncertainty was calculated for reproducing hardness numbers on the Leeb scales.


2008 ◽  
Vol 11 (-1) ◽  
pp. 265-276
Author(s):  
Sylwester Kłysz ◽  
Janusz Lisiecki

2008 ◽  
Vol 11 (-1) ◽  
pp. 253-264
Author(s):  
Sylwester Kłysz ◽  
Janusz Lisiecki

Sign in / Sign up

Export Citation Format

Share Document