Non-invasive glucose monitoring using open electromagnetic waveguides

Author(s):  
M. Hofmann ◽  
M. Bloss ◽  
R. Weigel ◽  
G. Fischer ◽  
D. Kissinger
Biosensors ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 189
Author(s):  
David Bamgboje ◽  
Iasonas Christoulakis ◽  
Ioannis Smanis ◽  
Gaurav Chavan ◽  
Rinkal Shah ◽  
...  

Diabetes mellitus (DM) is a chronic disease that must be carefully managed to prevent serious complications such as cardiovascular disease, retinopathy, nephropathy and neuropathy. Self-monitoring of blood glucose is a crucial tool for managing diabetes and, at present, all relevant procedures are invasive while they only provide periodic measurements. The pain and measurement intermittency associated with invasive techniques resulted in the exploration of painless, continuous, and non-invasive techniques of glucose measurement that would facilitate intensive management. The focus of this review paper is the existing solutions for continuous non-invasive glucose monitoring via contact lenses (CLs) and to carry out a detailed, qualitative, and comparative analysis to inform prospective researchers on viable pathways. Direct glucose monitoring via CLs is contingent on the detection of biomarkers present in the lacrimal fluid. In this review, emphasis is given on two types of sensors: a graphene-AgNW hybrid sensor and an amperometric sensor. Both sensors can detect the presence of glucose in the lacrimal fluid by using the enzyme, glucose oxidase. Additionally, this review covers fabrication procedures for CL biosensors. Ever since Google published the first glucose monitoring embedded system on a CL, CL biosensors have been considered state-of-the-art in the medical device research and development industry. The CL not only has to have a sensory system, it must also have an embedded integrated circuit (IC) for readout and wireless communication. Moreover, to retain mobility and ease of use of the CLs used for continuous glucose monitoring, the power supply to the solid-state IC on such CLs must be wireless. Currently, there are four methods of powering CLs: utilizing solar energy, via a biofuel cell, or by inductive or radiofrequency (RF) power. Although, there are many limitations associated with each method, the limitations common to all, are safety restrictions and CL size limitations. Bearing this in mind, RF power has received most of the attention in reported literature, whereas solar power has received the least attention in the literature. CLs seem a very promising target for cutting edge biotechnological applications of diagnostic, prognostic and therapeutic relevance.


Author(s):  
Herbert Fink ◽  
Tim Maihöfer ◽  
Jeffrey Bender ◽  
Jochen Schulat

Abstract Blood glucose monitoring (BGM) is the most important part of diabetes management. In classical BGM, glucose measurement by test strips involves invasive finger pricking. We present results of a clinical study that focused on a non-invasive approach based on volatile organic compounds (VOCs) in exhaled breath. Main objective was the discovery of markers for prediction of blood glucose levels (BGL) in diabetic patients. Exhaled breath was measured repeatedly in 60 diabetic patients (30 type 1, 30 type 2) in fasting state and after a standardized meal. Proton Transfer Reaction Time of Flight Mass Spectrometry (PTR-ToF-MS) was used to sample breath every 15 minutes for a total of six hours. BGLs were tested in parallel via BGM test strips. VOC signals were plotted against glucose trends for each subject to identify correlations. Exhaled indole (a bacterial metabolite of tryptophan) showed significant mean correlation to BGL (with negative trend) and significant individual correlation in 36 patients. The type of diabetes did not affect this result. Additional experiments of one healthy male subject by ingestion of lactulose and 13C-labeled glucose (n=3) revealed that exhaled indole does not directly originate from food digestion by intestinal microbiota. As indole has been linked to human glucose metabolism, it might be a tentative marker in breath for non-invasive BGM. Clinical studies with greater diversity are required for confirmation of such results and further investigation of metabolic pathways.


1997 ◽  
Vol 20 (5) ◽  
pp. 285-290 ◽  
Author(s):  
U.A. Müller ◽  
B. Mertes ◽  
C. Fischbacher ◽  
K.U. Jageman ◽  
K. Danzer

The feasibility of using near infrared reflection spectroscopy for non-invasive blood glucose monitoring is discussed. Spectra were obtained using a diode-array spectrometer with a fiberoptic measuring head with a wavelength ranging from 800 nm to 1350 nm. Calibration was performed using partial least-squares regression and radial basis function networks. The results of different methods used to evaluate the quality of the recorded spectra in order to improve the reliability of the calibration models, are presented.


Sensors ◽  
2021 ◽  
Vol 21 (20) ◽  
pp. 6820
Author(s):  
Bushra Alsunaidi ◽  
Murad Althobaiti ◽  
Mahbubunnabi Tamal ◽  
Waleed Albaker ◽  
Ibraheem Al-Naib

The prevalence of diabetes is increasing globally. More than 690 million cases of diabetes are expected worldwide by 2045. Continuous blood glucose monitoring is essential to control the disease and avoid long-term complications. Diabetics suffer on a daily basis with the traditional glucose monitors currently in use, which are invasive, painful, and cost-intensive. Therefore, the demand for non-invasive, painless, economical, and reliable approaches to monitor glucose levels is increasing. Since the last decades, many glucose sensing technologies have been developed. Researchers and scientists have been working on the enhancement of these technologies to achieve better results. This paper provides an updated review of some of the pioneering non-invasive optical techniques for monitoring blood glucose levels that have been proposed in the last six years, including a summary of state-of-the-art error analysis and validation techniques.


2021 ◽  
pp. 193229682110541
Author(s):  
Farid Sanai ◽  
Arshman S. Sahid ◽  
Jacqueline Huvanandana ◽  
Sandra Spoa ◽  
Lachlan H. Boyle ◽  
...  

Background: Frequent blood glucose level (BGL) monitoring is essential for effective diabetes management. Poor compliance is common due to the painful finger pricking or subcutaneous lancet implantation required from existing technologies. There are currently no commercially available non-invasive devices that can effectively measure BGL. In this real-world study, a prototype non-invasive continuous glucose monitoring system (NI-CGM) developed as a wearable ring was used to collect bioimpedance data. The aim was to develop a mathematical model that could use these bioimpedance data to estimate BGL in real time. Methods: The prototype NI-CGM was worn by 14 adult participants with type 2 diabetes for 14 days in an observational clinical study. Bioimpedance data were collected alongside paired BGL measurements taken with a Food and Drug Administration (FDA)-approved self-monitoring blood glucose (SMBG) meter and an FDA-approved CGM. The SMBG meter data were used to improve CGM accuracy, and CGM data to develop the mathematical model. Results: A gradient boosted model was developed using a randomized 80-20 training-test split of data. The estimated BGL from the model had a Mean Absolute Relative Difference (MARD) of 17.9%, with the Parkes error grid (PEG) analysis showing 99% of values in clinically acceptable zones A and B. Conclusions: This study demonstrated the reliability of the prototype NI-CGM at collecting bioimpedance data in a real-world scenario. These data were used to train a model that could successfully estimate BGL with a promising MARD and clinically relevant PEG result. These results will enable continued development of the prototype NI-CGM as a wearable ring.


Sign in / Sign up

Export Citation Format

Share Document