Determination of the probability of compliance of the measuring instruments with the metrological requirements

2018 ◽  
Vol 0 (3) ◽  
pp. 18-23
Author(s):  
Ігор Петрович Захаров ◽  
Павло Іванович Неєжмаков ◽  
Олеся Анатоліївна Боцюра
2018 ◽  
pp. 76-84
Author(s):  
K. V. Sorokin ◽  
E. A. Sunarchina

Improvement of orbits precision is one of the most important tasks of space surveillance catalogue maintenance. The solution of this problem is directly related to an adequate consideration of the errors of the coordinate information from the measuring instruments. The article consideresd a new method for estimating the precision of measuring instruments on the catalog orbits. To carry out such analysis, in PJSC «VIMPEL» special technological program was created. Main results of a study of radar errors with orbits of space surveillance catalogue was presented. Also, the results were compared with data of measuring instrument's calibration software complex. This software complex provides determination of satellite's position with errors less than 10 m. A new dynamic model of measuring instrument errors is proposed.


1978 ◽  
Vol 21 (2) ◽  
pp. 158-163
Author(s):  
I. V. Abuladze ◽  
A. I. Belyaevskii ◽  
A. A. Dzhevdet

2015 ◽  
Vol 8 (6) ◽  
pp. 2417-2435 ◽  
Author(s):  
F. Tack ◽  
F. Hendrick ◽  
F. Goutail ◽  
C. Fayt ◽  
A. Merlaud ◽  
...  

Abstract. We present an algorithm for retrieving tropospheric nitrogen dioxide (NO2) vertical column densities (VCDs) from ground-based zenith–sky (ZS) measurements of scattered sunlight. The method is based on a four-step approach consisting of (1) the differential optical absorption spectroscopy (DOAS) analysis of ZS radiance spectra using a fixed reference spectrum corresponding to low NO2 absorption, (2) the determination of the residual amount in the reference spectrum using a Langley-plot-type method, (3) the removal of the stratospheric content from the daytime total measured slant column based on stratospheric VCDs measured at sunrise and sunset, and simulation of the rapid NO2 diurnal variation, (4) the retrieval of tropospheric VCDs by dividing the resulting tropospheric slant columns by appropriate air mass factors (AMFs). These steps are fully characterized and recommendations are given for each of them. The retrieval algorithm is applied on a ZS data set acquired with a multi-axis (MAX-) DOAS instrument during the Cabauw (51.97° N, 4.93° E, sea level) Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI) held from 10 June to 21 July 2009 in the Netherlands. A median value of 7.9 × 1015 molec cm−2 is found for the retrieved tropospheric NO2 VCDs, with maxima up to 6.0 × 1016 molec cm−2. The error budget assessment indicates that the overall error σTVCD on the column values is less than 28%. In the case of low tropospheric contribution, σTVCD is estimated to be around 39% and is dominated by uncertainties in the determination of the residual amount in the reference spectrum. For strong tropospheric pollution events, σTVCD drops to approximately 22% with the largest uncertainties on the determination of the stratospheric NO2 abundance and tropospheric AMFs. The tropospheric VCD amounts derived from ZS observations are compared to VCDs retrieved from off-axis and direct-sun measurements of the same MAX-DOAS instrument as well as to data from a co-located Système d'Analyse par Observations Zénithales (SAOZ) spectrometer. The retrieved tropospheric VCDs are in good agreement with the different data sets with correlation coefficients and slopes close to or larger than 0.9. The potential of the presented ZS retrieval algorithm is further demonstrated by its successful application on a 2-year data set, acquired at the NDACC (Network for the Detection of Atmospheric Composition Change) station Observatoire de Haute Provence (OHP; Southern France).


2010 ◽  
Vol 82 (12) ◽  
pp. 2315-2335 ◽  
Author(s):  
Ute Resch-Genger ◽  
Paul C. DeRose

Chromophore-based fluorescence standards for the characterization of photo-luminescence measuring systems and the determination of relevant fluorometric quantities are classified according to their scope and area of application. General and type-specific requirements for suitable standards are derived for each class of standards. Metrological requirements linked to the realization of comparable measurements are addressed and recommendations on selecting, using, and developing fluorescence standards are given.


2014 ◽  
Vol 14 (5) ◽  
pp. 263-269 ◽  
Author(s):  
Dimitar Dichev ◽  
Hristofor Koev ◽  
Totka Bakalova ◽  
Petr Louda

Abstract The present paper considers a new measurement concept of modeling measuring instruments for gyro-free determination of the parameters of moving objects. The proposed approach eliminates the disadvantages of the existing measuring instruments since it is based, on one hand, on a considerably simplified mechanical module, and on the other hand, on the advanced achievements in the area of nanotechnologies, microprocessor and computer equipment. A specific measuring system intended for measuring the trim, heel, roll, and pitch of a ship has been developed in compliance with the basic principles of this concept. The high dynamic accuracy of this measuring system is ensured by an additional measurement channel operating in parallel with the main channel. The operating principle of the additional measurement channel is based on an appropriate correction algorithm using signals from linear MEMS accelerometers. The presented results from the tests carried out by means of stand equipment in the form of a hexapod of six degrees of freedom prove the effectiveness of the proposed measurement concept


Sign in / Sign up

Export Citation Format

Share Document