scholarly journals Experimental Investigation on Punching Behavior of Thick Reinforced Concrete Slabs

2013 ◽  
Vol 59 (2) ◽  
pp. 157-174 ◽  
Author(s):  
T. Urban ◽  
M. Gołdyn ◽  
J. Krakowski ◽  
Ł. Krawczyk

Abstract The results of experimental test of nine thickset reinforced concrete slabs in punching are presented in the this paper. The aim of the tests was verification of the Eurocode EC 2 procedure, by which the ultimate shear stresses vRd,c depend on the slenderness of the slab. Besides of the performed tests results, the analysis of the foreign investigation of the fundaments is also included. The test results, as well as other tests, show the correctness of the function assumed in Eurocode 2, which gives correlation between ultimate stresses vRd,c and shear slenderness.

2014 ◽  
Vol 13 (3) ◽  
pp. 183-192
Author(s):  
Tadeusz Urban ◽  
Jakub Krakowski

The punching shear behavior of thick reinforced concrete slabs was analyzed in this paper by using strut-and-tie model (S-T). Calculating procedures were compared to our own experimental test results. The analyzed elements were subjected to symmetric loading and without shear reinforcement.


Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4622
Author(s):  
Kevin Paolo V. Robles ◽  
Jurng-Jae Yee ◽  
Seong-Hoon Kee

The main objectives of this study are to evaluate the effect of geometrical constraints of plain concrete and reinforced concrete slabs on the Wenner four-point concrete electrical resistivity (ER) test through numerical and experimental investigation and to propose measurement recommendations for laboratory and field specimens. First, a series of numerical simulations was performed using a 3D finite element model to investigate the effects of geometrical constraints (the dimension of concrete slabs, the electrode spacing and configuration, and the distance of the electrode to the edges of concrete slabs) on ER measurements of concrete. Next, a reinforced concrete slab specimen (1500 mm (width) by 1500 mm (length) by 300 mm (thickness)) was used for experimental investigation and validation of the numerical simulation results. Based on the analytical and experimental results, it is concluded that measured ER values of regularly shaped concrete elements are strongly dependent on the distance-to-spacing ratio of ER probes (i.e., distance of the electrode in ER probes to the edges and/or the bottom of the concrete slabs normalized by the electrode spacing). For the plain concrete, it is inferred that the thickness of the concrete member should be at least three times the electrode spacing. In addition, the distance should be more than twice the electrode spacing to make the edge effect almost negligible. It is observed that the findings from the plain concrete are also valid for the reinforced concrete. However, for the reinforced concrete, the ER values are also affected by the presence of reinforcing steel and saturation of concrete, which could cause disruptions in ER measurements


2012 ◽  
Vol 256-259 ◽  
pp. 850-854
Author(s):  
Yong Wang ◽  
Yu Li Dong

This paper presents the latest developments of a simple method used to determine the ultimate load of two-way simply supported reinforced concrete slabs. Based on the reinforcement ratio, two failure criteria are proposed in the paper. The effectiveness of the developed model is validated through satisfactory comparison with from test results.


2014 ◽  
Vol 501-504 ◽  
pp. 1048-1052 ◽  
Author(s):  
Xiao Jin Li ◽  
Yi Yan Lu ◽  
Na Li

A total of four two-way reinforced concrete slabs strengthened with three methods were tested. The four test specimens were one unstrengthened reinforced concrete slab (control), one slab strengthened with CFRP strips, one slab strengthened with steel sheets, and one slab strengthened with an innovative method of applying CFRP strips and steel sheets combination bonding to the tension face of the slab. The test results show the CFRP-Steel combination strengthened technique is a rapid and effective strengthening technique for two-way RC slab. The increase in ultimate capacities of CFRP-Steel combination strengthened slab is 221.1% over the control slab, 84.4% over the CFRP-strengthened slab, and 45.2% over the steel-strengthened slab. In addition, the CFRP-Steel combination strengthened slab exhibited superior ductility than the CFRP-strengthened slab.


Materials ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 5046
Author(s):  
Hyeong-Yeol Kim ◽  
Young-Jun You ◽  
Gum-Sung Ryu

A textile reinforced concrete (TRC) system has been widely used for repair and strengthening of deteriorated reinforced concrete (RC) structures. This paper proposes an accelerated on-site installation method of a TRC system by grouting to strengthen deteriorated RC structures. Four RC slabs were strengthened with one ply of carbon textile grid and 20 mm-thick cementitious grout. The TRC strengthened slab specimens were tested under flexure and the test results were compared with those of an unstrengthened specimen and theoretical solutions. Furthermore, the TRC strengthened specimens experienced longer plastic deformation after steel yield than the unstrengthened specimen. The TRC strengthened specimens exhibited many fine cracks and finally failed by rupture of the textile. Therefore, TRC system with the proposed installation method can effectively be used for strengthening of deteriorated RC structural elements. The theoretically computed steel yield and ultimate loads overestimate the test data by 11% and 5%, respectively.