scholarly journals Determination of natural and synthetic oestrogens in surface water using gas chromatography-mass spectrometry

2014 ◽  
Vol 58 (4) ◽  
pp. 603-611 ◽  
Author(s):  
Barbara Woźniak ◽  
Alicja Kłopot ◽  
Iwona Matraszek-Żuchowska ◽  
Katarzyna Sielska ◽  
Jan Żmudzki

Abstract A simple and sensitive gas chromatography method was developed to determine a group of oestrogens in surface water. In the first stage of analysis, enzymatic hydrolysis of oestrogen metabolites with glucuronidase AS-HP was performed. Free compounds were extracted from 200 mL of water sample on C18 SPE column (6 mL, 1000 mg). The evaporated extract was subjected to derivatisation with a mixture of MSTFA/NH4I/DTT (1000:2:5, v/w/w). The separation of the analytes on HP-5ms capillary column was conducted. The method was validated according to the Commission Decision 2002/657/EC. Recovery in spiked samples ranged from 90% to 120 % with standard deviation lower than 30% for all examined compounds. The decision limit and detection capability of five oestrogens were in the range of 0.3-0.6 ng L-1 and 0.5-0.9 ng L-1, respectively. Nineteen water samples collected from different sites of several Polish rivers and lakes were tested for the presence of oestrogens. Some target compounds such as 17α-oestradiol, 17β-oestradiol, oestrone, oestriol, and 17α-ethynyloestradiol were found in trace amounts in the analysed samples. The highest concentration observed for oestradiol reached 23 ng L-1.

1987 ◽  
Vol 70 (5) ◽  
pp. 912-915 ◽  
Author(s):  
Randall L Smith ◽  
Darryl M Sullivan ◽  
Earl F Richter

Abstract A positive bias in the gas chromatographic (GC) analysis of butter for β-sitosterol was discovered when attempting to confirm values by gas chromatography/mass spectrometry (GC/MS). The source of the problem was traced to an interfering material that was not effectively separated by packed column GC. Because capillary columns are known to provide superior separation, they were substituted for packed columns in the assay, and instrument parameters were modified accordingly. A compound with a similar retention time, identified by GC/MS as lanosterol, was separated from β-sitosterol by the capillary column. The capillary column technique was applied to over 300 butter samples. The results indicate that the method can accurately quantitate β-sitosterol in butter with no known interferences. The limit of detection for this method is 1 mg/100 g. Recoveries at a level of 3 mg/100 g averaged 98% with a coefficient of variation of 3.45%


Sign in / Sign up

Export Citation Format

Share Document