scholarly journals Long-Term Follow-Up in Tumoral Arthroplasty

2018 ◽  
Vol 1 (Supplement) ◽  
pp. 54
Author(s):  
G. Iacobescu ◽  
R. Ene ◽  
A. Cursaru ◽  
D. Anghelescu ◽  
C. Cîrstoiu

Abstract Introduction. Efficient management of a segmental resection or major osteolysis in the distal femur secondary to a tumor formation remains a controversial problem. Available options include the use of a modular or customized megaprosthetic implant. Modularity allows versatility for reconstruction and avoids the delay required to make a customized implant. Hypothesis and type of study. Performing a clinical and radiological retrospective study that aims to evaluate long-term efficiency in the use of megaprostheses in segmental distal femur resections. Elaboration of patient selection criteria for modular prosthesis. Materials and methods. We followed retrospectively 33 patients for 5 years from the time of the first surgery. We evaluated the implant stability, the late complications rate, and the long-term functional recovery of patients with distal femoral tumors who underwent segmental resections and subsequently reconstructive arthroplasty. Results. Thirty of the 33 patients maintained a mobile knee joint. An intermediate staging was performed at 30 months, which determined tumor recurrence in 2 patients, aseptic degradation of the components in 3 of them, and septic degradation in two of the evaluated cases. Because a tumoral recurrence occurred on the 45th month, the need for amputation of the prosthetic limb was imposed. The degradation of the polyethylene component (in 5 cases) was observed in the 5-year assessment. The functional results were excellent with the Musculoskeletal Tumor Society Score of 88% and a Toronto Extremity Severity Scale Score of 94%. Conclusions. Patients with distal femoral bone tumors undergoing modular reconstruction prosthetic arthroplasty have excellent functional results with retaining the affected limb and knee mobility. There was a close correlation between correctly applying the selection criteria for patients undergoing prosthesis intervention and functional recovery results.

2019 ◽  
Vol 33 (08) ◽  
pp. 818-824
Author(s):  
Joseph A. Ippolito ◽  
Megan L. Campbell ◽  
Brianna L. Siracuse ◽  
Joseph Benevenia

AbstractFor patients with tumors of the distal femur, options for limb salvage include tumor resection followed by reconstruction. While reconstruction commonly involves a distal femoral replacement, careful selection of patients with tumor involvement limited to a single condyle may be candidates for reconstruction with distal femur hemiarthroplasty. In these procedures, resection spares considerably more native anatomy. Three consecutive patients who underwent resection and reconstruction at the distal femur with custom unicondylar hemiarthroplasty are presented in this case series at a mean follow-up of 45 months (range, 26–78). In two cases, prostheses were utilized as a secondary procedure after failure of initial reconstruction. In one case, the custom prosthesis was utilized as the primary method of reconstruction. Mean Musculoskeletal Tumor Society disease-specific scores were 26.7 (range, 25–28). All patients achieved a return to full weight bearing, activities of daily living, and functional range of motion. In appropriately selected patients with tumors of the distal femur, reconstruction with custom unicondylar hemiarthroplasty provides benefits including optimal function postoperatively via preservation of tumor-free bone and ligamentous structures. Additionally, maintenance of greater bone stock may confer benefits to patients with pathology at a high likelihood for recurrence and need for subsequent procedures.


2019 ◽  
Vol 101-B (9) ◽  
pp. 1151-1159 ◽  
Author(s):  
N. Oike ◽  
H. Kawashima ◽  
A. Ogose ◽  
H. Hatano ◽  
T. Ariizumi ◽  
...  

Aims We analyzed the long-term outcomes of patients observed over ten years after resection en bloc and reconstruction with extracorporeal irradiated autografts Patients and Methods This retrospective study included 27 patients who underwent resection en bloc and reimplantation of an extracorporeal irradiated autograft. The mean patient age and follow-up period were 31.7 years (9 to 59) and 16.6 years (10.3 to 24.3), respectively. The most common diagnosis was osteosarcoma (n = 10), followed by chondrosarcoma (n = 6). The femur (n = 13) was the most frequently involved site, followed by the tibia (n = 7). There were inlay grafts in five patients, intercalary grafts in 15 patients, and osteoarticular grafts in seven patients. Functional outcome was evaluated with the Musculoskeletal Tumor Society (MSTS) scoring system. Results There were no recurrences in the irradiated autograft and the autograft survived in 24 patients (88.9%). Major complications included nonunion (n = 9), subchondral bone collapse (n = 4), and deep infection (n = 4). Although 34 revision procedures were performed, 25 (73.5%) and four (11.8%) of these were performed less than five years and ten years after the initial surgery, respectively. The mean MSTS score at the last follow-up was 84.3% (33% to 100%). Conclusion Considering long-term outcomes, extracorporeal irradiated autograft is an effective method of reconstruction for malignant musculoskeletal tumours Cite this article: Bone Joint J 2019;101-B:1151–1159


2019 ◽  
Vol 11 (1) ◽  
Author(s):  
Markus Nottrott ◽  
Arne Streitbürger ◽  
Georg Gosheger ◽  
Wiebke Guder ◽  
Gregor Hauschild ◽  
...  

Intra-articular sarcoma of the knee joint is a very rare condition. Extra-articular resection and reconstruction with a tumor prosthesis is usually performed. This report describes the results with this rare surgical procedure. This retrospective study evaluated the clinical and functional results after extra-articular resection of the knee joint in eight patients with soft-tissue sarcomas of the knee that were reconstructed using a tumor endoprosthesis. Five of the eight patients (62.5%) ultimately had to undergo amputation, mainly due to periprosthetic infection. In addition, two patients experienced periprosthetic fractures. The mean Musculoskeletal Tumor Society score was 18 (range 10-22), as function was impaired due to a weak extensor mechanism. These results suggest that in patients with intraarticular soft-tissue sarcomas, limb salvage procedures with tumor prostheses after extra-articular resection are associated with very high complication rates. In most cases, long-term limb salvage was not possible. When limb salvage is successful, function is also poor due to a weak extensor mechanism in the knee joint. The indication for this procedure should therefore be considered critically.


2018 ◽  
Vol 100-B (8) ◽  
pp. 1094-1099 ◽  
Author(s):  
S. Gupta ◽  
A. Malhotra ◽  
N. Mittal ◽  
S. K. Garg ◽  
R. Jindal ◽  
...  

Aims The aims of this study were to establish whether composite fixation (rail-plate) decreases fixator time and related problems in the management of patients with infected nonunion of tibia with a segmental defect, without compromising the anatomical and functional outcomes achieved using the classical Ilizarov technique. We also wished to study the acceptability of this technique using patient-based objective criteria. Patients and Methods Between January 2012 and January 2015, 14 consecutive patients were treated for an infected nonunion of the tibia with a gap and were included in the study. During stage one, a radical debridement of bone and soft tissue was undertaken with the introduction of an antibiotic-loaded cement spacer. At the second stage, the tibia was stabilized using a long lateral locked plate and a six-pin monorail fixator on its anteromedial surface. A corticotomy was performed at the appropriate level. During the third stage, i.e. at the end of the distraction phase, the transported fragment was aligned and fixed to the plate with two to four screws. An iliac crest autograft was added to the docking site and the fixator was removed. Functional outcome was assessed using the Association for the Study and Application of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) score. Results The mean age of patients was 38.1 years (sd 12.7). There were 13 men and one woman. The mean size of the defect was 6.4 cm (sd 1.3). the mean follow-up was 33.2 months (24 to 50). The mean external fixator index was 21.2 days/cm (sd 1.5). The complication rate was 0.5 (7/14) per patient. According to the classification of Paley, there were five problems and two obstacles but no true complications. The ASAMI bone score was excellent in all patients. The functional ASAMI scores were excellent in eight and good in six patients. The mean MSTS composite score was 83.9% (sd 7.1), with an MSTS emotional acceptance score of 4.9 (sd 0.5; maximum possible 5). Conclusion Composite fixation (rail-plate) decreases fixator time and the associated complications, in the treatment of patients of infected nonunion tibia with a segmental defect. It also provides good anatomical and functional results with high emotional acceptance. Cite this article: Bone Joint J 2018;100-B:1094–9.


2020 ◽  
Author(s):  
gang xu ◽  
Shinji Miwa ◽  
Norio Yamamoto ◽  
Katsuhiro Hayashi ◽  
Akihiko Takeuchi ◽  
...  

Abstract Background Limb salvage surgery is becoming increasingly popular after tumor resection in the lower extremity. Biological reconstruction and use of megaprosthesis are main methods for malignant bone tumors of the proximal femur, which remain controversial due to short- and long-term complication in the proximal femur. Tumor-bearing bone treated by liquid nitrogen is one of biological reconstruction. This study aimed to evaluate the mid- and long-term functional outcomes and complications in patients treated with frozen autograft–prosthesis composite (FAPC) reconstructions in the proximal femur. Methods This retrospective study included 19 patients (10 women, 9 men) with malignant tumors of the proximal femur who underwent tumor-wide resection and FAPC reconstruction (mean age, 46 years; range, 9-77 years). The mean follow-up period of 69 months (range, 9-179 month). Functional outcomes, oncological outcomes and complications were evaluated by Musculoskeletal Tumor Society score, clinical and radiological examinations. Results The overall survival rate was 68.4%, and the mean Musculoskeletal Tumor Society functional score was 26.4 points (88%). FAPC survival rates were 100% and 50% at 5 and 10 years, respectively. Five of the 19 patients (26%) had complications: 2 required prosthesis removal and 2 developed a deep infection around acetabular. Wear of the acetabulum occurred in 2 cases, while disease recurrence was occurred in 1 case. There were no cases of greater trochanter avulsion, obvious absorption around frozen bone, prosthesis loosening or leg length discrepancy. Conclusions Due to without femoral osteotomy, this technique features satisfactory functional outcome and provide biomechanical stability that is comparable to those of other methods of biological reconstruction or megaprosthesis.


2012 ◽  
Vol 27 (2) ◽  
pp. 95-101 ◽  
Author(s):  
Erika Sajtos ◽  
Anita Balint ◽  
Endre Brath ◽  
Norbert Nemeth ◽  
Katalin Peto ◽  
...  

PURPOSE: To examine the possible late complications of splenectomy or spleen autotransplantation in large laboratory animal model, in which we need non-invasive or minimal-invasive methods for long-term monitoring of the experimental animals. METHODS: Experimental groups of beagle dogs were: non-operated control, sham-operated control, splenectomy, spleen autotransplantation with 5 or 10 spleen-chips taken into the greater omentum (Furka's technique). Prior to operations, on the 1st postoperative week, monthly till the 6th as well as in the 9th and 12th month, hemorheological examinations were performed. In postoperative 12th month colloid scintigraphy and diagnostic laparoscopy were carried out. At the end of the investigation comparative morphological examinations were performed, too. RESULTS: From the 4th-5th postoperative month filtration function of spleen-autotransplants showed particular restoration compared to splenectomy group. However, the functional results did not reach the values of the control or sham-operated groups. Sham-operated control's scintigraphy nicely showed activity in the spleen. In spleen autotransplantation-groups scintigraphy indicated well the activity of spleen-chips. During diagnostic laparoscopy spleen-chips with their blood supply were found. Histologically, the structure of spleenautotransplants was similar to normal splenic tissue. CONCLUSIONS: The autotransplants are regenerated, their functions have been partly restored, and thus spleen autotransplantation may prevent the possible complications of splenectomy. These parameters and the presented investigative protocol are suitable for long-term following-up of viability of the spleen-autotransplants.


2020 ◽  
Vol 36 (05) ◽  
pp. 386-396
Author(s):  
Meghan C. McCullough ◽  
Alexandre Arkader ◽  
Rojine Ariani ◽  
Nina Lightdale-Miric ◽  
Vernon Tolo ◽  
...  

Abstract Background In the pediatric population, bony defects of the extremities pose a significant challenge for which free vascularized fibular grafts (FVFGs) represent a valuable reconstructive option. The purpose of this study was to explore surgical outcomes, complications, and long-term functionality of FVFG for this patient group. Methods Using MEDLINE and PubMed databases, studies were identified of pediatric extremity reconstruction using FVFG which reported functional outcomes and/or complications. The operative logs at a tertiary pediatric center were then reviewed for cases of FVFG between January 2000 and 2017. Demographic characteristics, surgical indications, operative details, graft survival, bony union, complications, and functionality of the reconstruction were recorded. Results A total of 366 studies were identified with 23 ultimately meeting inclusion criteria in the systematic review. In the institutional series, 29 patients were included with mean age of 9.7 years (1–17 years). Indications for reconstruction included malignant bone tumor (n = 11), osteomyelitis (n = 9), congenital pseudoarthrosis (n = 6), and osteofibrous dysplasia (n = 3). Major postoperative complications included graft nonunion (24.1%), fracture (17.2%), and hardware failure (17.2%). Thirteen patients (44.8%) experienced delayed complications, while two (6.8%) experienced an immediate complication. Complications occurred in the donor site in 2 cases and the recipient site in all 13 cases. Long-term graft survival was achieved in 27 patients (93.1%), and 23 (79.3%) had full functional recovery, with an average Musculoskeletal Tumor Society score of 90% (60–100%). Mean follow-up was 5.17 years (2–12 years). Conclusion This review and institutional series demonstrate the versatility of FVFG to facilitate limb reconstruction in large defects or serve as a salvage option in complex cases. While immediate and donor-site complications are uncommon, delayed recipient-site complications are frequent, and patients and families should be counseled regarding this expectation. Though technically challenging, excellent long-term graft viability and functional recovery can be achieved in the large majority of patients.


2020 ◽  
Vol 102-B (2) ◽  
pp. 170-176 ◽  
Author(s):  
Nicholas M. Bernthal ◽  
Zachary D. C. Burke ◽  
Vishal Hegde ◽  
Alexander Upfill-Brown ◽  
Clark J. Chen ◽  
...  

Aims We aimed to examine the long-term mechanical survivorship, describe the modes of all-cause failure, and identify risk factors for mechanical failure of all-polyethylene tibial components in endoprosthetic reconstruction. Methods This is a retrospective database review of consecutive endoprosthetic reconstructions performed for oncological indications between 1980 and 2019. Patients with all-polyethylene tibial components were isolated and analyzed for revision for mechanical failure. Outcomes included survival of the all-polyethylene tibial component, revision surgery categorized according to the Henderson Failure Mode Classification, and complications and functional outcome, as assessed by the Musculoskeletal Tumor Society (MSTS) score at the final follow-up. Results A total of 278 patients were identified with 289 all-polyethylene tibial components. Mechanical survival was 98.4%, 91.1%, and 85.2% at five, ten and 15 years, respectively. A total of 15 mechanical failures were identified at the final follow-up. Of the 13 all-polyethylene tibial components used for revision of a previous tibial component, five (38.5%) failed mechanically. Younger patients (< 18 years vs > 18 years; p = 0.005) and those used as revision components (p < 0.001) had significantly increased rates of failure. Multivariate logistic regression modelling showed revision status to be a positive risk factor for failure (odds ratio (OR) 19.498, 95% confidence interval (CI) 4.598 to 82.676) and increasing age was a negative risk factor for failure (OR 0.927, 95% CI 0.872 to 0.987). Age-stratified risk analysis showed that age > 24 years was no longer a statistically significant risk factor for failure. The final mean MSTS score for all patients was 89% (8.5% to 100.0%). Conclusion The long-term mechanical survivorship of all-polyethylene tibial components when used for tumour endoprostheses was excellent. Tumour surgeons should consider using these components for their durability and the secondary benefits of reduced cost and ease of removal and revision. However, caution should be taken when using all-polyethylene tibial components in the revision setting as a significantly higher rate of mechanical failure was seen in this group of patients. Cite this article: Bone Joint J. 2020;102-B(2):170–176


2020 ◽  
Author(s):  
gang xu ◽  
Shinji Miwa ◽  
Norio Yamamoto ◽  
Katsuhiro Hayashi ◽  
Akihiko Takeuchi ◽  
...  

Abstract Background Limb salvage surgery is becoming increasingly popular after tumor resection in the lower extremity. Biological reconstruction and use of megaprosthesis are main methods for malignant bone tumors of the proximal femur, which remain controversial due to short- and long-term complication in the proximal femur. Tumor-bearing bone treated by liquid nitrogen is one of biological reconstruction. This study aimed to evaluate the mid- and long-term functional outcomes and complications in patients treated with frozen autograft–prosthesis composite (FAPC) reconstructions in the proximal femur. Methods This retrospective study included 19 patients (10 women, 9 men) with malignant tumors of the proximal femur who underwent tumor-wide resection and FAPC reconstruction (mean age, 46 years; range, 9-77 years). The mean follow-up period of 69 months (range, 9-179 month). Functional outcomes, oncological outcomes and complications were evaluated by Musculoskeletal Tumor Society score, clinical and radiological examinations. Results The overall survival rate was 68.4%, and the mean Musculoskeletal Tumor Society functional score was 26.4 points (88%). FAPC survival rates were 100% and 50% at 5 and 10 years, respectively. Five of the 19 patients (26%) had complications: 2 required prosthesis removal and 2 developed a deep infection around acetabular. Wear of the acetabulum occurred in 2 cases, while disease recurrence was occurred in 1 case. There were no cases of greater trochanter avulsion, obvious absorption around frozen bone, prosthesis loosening or leg length discrepancy. Conclusions Due to without femoral osteotomy, this technique features satisfactory functional outcome and provide biomechanical stability that is comparable to those of other methods of biological reconstruction or megaprosthesis.


2006 ◽  
Vol 24 (18_suppl) ◽  
pp. 19501-19501
Author(s):  
M. Aono ◽  
I. Kudawara ◽  
K. Ohzono ◽  
Y. Aoki ◽  
A. Matsumine ◽  
...  

19501 Background: There are several options for the surgical management of osteosarcoma (OS) especially in the skeletally immature patients. We evaluate the clinical results and quality of life (QOL) of OS patients with limb salvage operations. Methods: From 1996 to 2005, ten children with newly diagnosed previously untreated nonmetastatic (stage IIB) OS of extremities were reviewed. There were 5 females and 5 males. The median age was 12 years (range, 8 to 14). Tumor locations: proximal humerus in 2, proximal femur in 1, distal femur in 2, proximal tibia in 3, distal tibia in 1, and tibial shaft in 1. Patients received neoadjuvant and adjuvant chemotherapy, and local wide resection of tumor. Limb salvage procedures: intraoperative extracorporeal autogenous irradiated bone graft (IORBG) in 4 and prosthetic replacement in 6. The functional results were measured for the patients accordance with the Musculoskeletal Tumor Society rating score. Results: With a median follow up of 4 years (range, 1 to 9), 7 were continuously disease free, 2 died of disease and in one there was no evidence of disease. No local recurrence was seen. Mean functional rating scores of patients with IORBG and prosthetic replacement were 82% (range 77 to 90) and 82% (range 57 to 93), respectively. Functional results were not different between these study groups and relatively good. There was one infection in patients with prosthetic replacement. There were subchondral collapse in 2 (50%), fracture in 1 (25%) and infection in 1 (25%) with IORBG. Conclusions: Limb salvage operation with neoadjuvant chemotherapy is the optimum treatment. However there remain several problems of function after limb salvage operations, with improvement of survival of pediatric osteosarcoma patient. We should select the most suitable surgical procedure to achieve the good function of limbs as well as local control. No significant financial relationships to disclose.


Sign in / Sign up

Export Citation Format

Share Document