scholarly journals Correlations between heat release rate and gaseous by-product concentrations applied to the characterization of forest fuels

Author(s):  
I. Fernández-Gómez ◽  
J. Madrigal ◽  
A. J. de Castro ◽  
M. Guijarro ◽  
J. M. Aranda ◽  
...  
2019 ◽  
Vol 154 ◽  
pp. 44-51 ◽  
Author(s):  
Yao Liu ◽  
Jianguo Tan ◽  
Hao Wang ◽  
Liang Lv

2018 ◽  
Vol 16 (1) ◽  
pp. 108-115 ◽  
Author(s):  
A.A. Hanna ◽  
M.A. Nour ◽  
E.R. Souaya ◽  
M.A. sherief ◽  
A.S. Abdelmoaty

AbstractFire performance of polypropylene (PP) containing different percentages of ammonium polyphosphate (APP) with montmorillonite (Mt) or treated montmorillonite (MtT) was carried out by using the cone calorimeter test (CCT). Different samples from ammonium polyphosphate and montmorillonite were mixed with 90% polypropylene. The characterization of the prepared samples indicates that there is incorporation between the components of the samples. Heat release rate (HRR), peak heat release rate (PHRR), average heat release rate (Av-HRR), and time to ignition (TTI) of the samples were obtained from the cone calorimeter test. Also, the fire performance index (FPI) and the fire growth rate (FIGRA) were calculated. The interpretation of the curves and the parameters results from the cone calorimeter test which indicates that the addition of montmorillonite to APP increases its action as a flame retardant for PP. Moreover, the samples contain acid treatment montmorillonite showed an increase in the efficiency of ammonium polyphosphate when used. This result may be due to an increase in the SiO2 content by acid treatment.


2008 ◽  
Vol 18 (2) ◽  
pp. 111-124 ◽  
Author(s):  
C. Chen ◽  
L. Qu ◽  
Y. X. Yang ◽  
G. Q. Kang ◽  
W. K. Chow

2021 ◽  
Vol 11 (7) ◽  
pp. 3247
Author(s):  
Dong Hwan Kim ◽  
Chi Young Lee ◽  
Chang Bo Oh

In this study, the effects of discharge area and atomizing gas type in a twin-fluid atomizer on heptane pool fire-extinguishing performance were investigated under the heat release rate conditions of 1.17 and 5.23 kW in an enclosed chamber. Large and small full cone twin-fluid atomizers were prepared. Nitrogen and air were used as atomizing gases. With respect to the droplet size of water mist, as the water and air flow rates decreased and increased, respectively, the Sauter mean diameter (SMD) of the water mist decreased. The SMD of large and small atomizers were in the range of approximately 12–60 and 12–49 μm, respectively. With respect to the discharge area effect, the small atomizer exhibited a shorter extinguishing time, lower peak surface temperature, and higher minimum oxygen concentration than the large atomizer. Furthermore, it was observed that the effect of the discharge area on fire-extinguishing performance is dominant under certain flow rate conditions. With respect to the atomizing gas type effect, nitrogen and air appeared to exhibit nearly similar extinguishing times, peak surface temperatures, and minimum oxygen concentrations under most flow rate conditions. Based on the present and previous studies, it was revealed that the effect of atomizing gas type on fire-extinguishing performance is dependent on the relative positions of the discharged flow and fire source.


Fuel ◽  
2021 ◽  
Vol 288 ◽  
pp. 119656
Author(s):  
Robbert Willems ◽  
Frank Willems ◽  
Niels Deen ◽  
Bart Somers

Sign in / Sign up

Export Citation Format

Share Document