Realization of Multifunctional Surfaces Containing MEMS-based DBD Plasma Actuators and Biomimetic Structures for Flow Manipulation

Author(s):  
Dominik J. Berndt ◽  
Matthias G. Lindner ◽  
Rupert Schreiner ◽  
Rüdiger Hink ◽  
Andrei Pipa ◽  
...  
2017 ◽  
Vol 50 (47) ◽  
pp. 475204 ◽  
Author(s):  
V F Kopiev ◽  
P N Kazansky ◽  
V A Kopiev ◽  
I A Moralev ◽  
M Yu Zaytsev
Keyword(s):  

Author(s):  
Alexander Duchmann ◽  
Bernhard Simon ◽  
Philip Magin ◽  
Cameron Tropea ◽  
Sven Grundmann

2012 ◽  
Vol 135 (1) ◽  
Author(s):  
Christopher R. Marks ◽  
Rolf Sondergaard ◽  
Mitch Wolff ◽  
Rich Anthony

This paper presents experimental work comparing several Dielectric Barrier Discharge (DBD) plasma actuator configurations for low Reynolds number separation control. Actuators studied here are being investigated for use in a closed loop separation control system. The plasma actuators were fabricated in the U.S. Air Force Research Laboratory Propulsion Directorate’s thin film laboratory and applied to a low Reynolds number airfoil that exhibits similar suction surface behavior to those observed on Low Pressure (LP) Turbine blades. In addition to typical asymmetric arrangements producing downstream jets, one electrode configurations was designed to produce an array of off axis jets, and one produced a spanwise array of linear vertical jets in order to generate vorticity and improved boundary layer to freestream mixing. The actuators were installed on an airfoil and their performance compared by flow visualization, surface stress sensitive film (S3F), and drag measurements. The experimental data provides a clear picture of the potential utility of each design. Experiments were carried out at four Reynolds numbers, 1.4 × 105, 1.0 × 105, 6.0 × 104, and 5.0 × 104 at a-1.5 deg angle of attack. Data was taken at the AFRL Propulsion Directorate’s Low Speed Wind Tunnel (LSWT) facility.


2021 ◽  
Author(s):  
F. F. Rodrigues ◽  
J. Nunes-Pereira ◽  
M. Abdollahzadeh ◽  
J. Pascoa ◽  
S. Lanceros-Mendez

Abstract Dielectric Barrier Discharge (DBD) plasma actuators are simple devices with great potential for active flow control applications. Further, it has been recently proven their ability for applications in the area of heat transfer, such as film cooling of turbine blades or ice removal. The dielectric material used in the fabrication of these devices is essential in determining the device performance. However, the variety of dielectric materials studied in the literature is very limited and the majority of the authors only use Kapton, Teflon, Macor ceramic or poly(methyl methacrylate) (PMMA). Furthermore, several authors reported difficulties in the durability of the dielectric layer when the actuators operate at high voltage and frequency. Also, it has been reported that, after long operation time, the dielectric layer suffers degradation due to its exposure to plasma discharge, degradation that may lead to the failure of the device. Considering the need of durable and robust actuators, as well as the need of higher flow control efficiencies, it is highly important to develop new dielectric materials which may be used for plasma actuator fabrication. In this context, the present study reports on the experimental testing of dielectric materials which can be used for DBD plasma actuators fabrication. Plasma actuators fabricated of poly(vinylidene fluoride) (PVDF) and polystyrene (PS) have been fabricated and evaluated. Although these dielectric materials are not commonly used as dielectric layer of plasma actuators, their interesting electrical and dielectric properties and the possibility of being used as sensors, indicate their suitability as potential alternatives to the standard used materials. The plasma actuators produced with these nonstandard dielectric materials were analyzed in terms of electrical characteristics, generated flow velocity and mechanical efficiency, and the obtained results were compared with a standard actuator made of Kapton. An innovative calorimetric method was implemented in order to estimate the thermal power transferred by these devices to an adjacent flow. These results allowed to discuss the ability of these new dielectric materials not only for flow control applications but also for heat transfer applications.


2018 ◽  
Vol 30 (9) ◽  
pp. 4141-4154
Author(s):  
Abbas Ebrahimi ◽  
Majid Hajipour ◽  
Kamran Ghamkhar

PurposeThe purpose of this paper is to control flow separation over a NACA 4415 airfoil by applying unsteady forces to the separated shear layers using dielectric barrier discharge (DBD) plasma actuators. This novel flow control method is studied under conditions which the airfoil angle of attack is 18°, and Reynolds number based on chord length is 5.5 × 105.Design/methodology/approachLarge eddy simulation of the turbulent flow is used to capture vortical structures through the airfoil wake. Power spectral density analysis of the baseline flow indicates dominant natural frequencies associated with “shear layer mode” and “wake mode.” The wake mode frequency is used simultaneously to excite separated shear layers at both the upper surface and the trailing edge of the airfoil (dual-position excitation), and it is also used singly to excite the upper surface shear layer (single-position excitation).FindingsBased on the results, actuations manipulate the shear layers instabilities and change the wake patterns considerably. It is revealed that in the single-position excitation case, the vortices shed from the upper surface shear layer are more coherent than the dual-position excitation case. The maximum value of lift coefficient and lift-to-drag ratio is achieved, respectively, by single-position excitation as well as dual-position excitation.Originality/valueThe paper contributes to the understanding and progress of DBD plasma actuators for flow control applications. Further, this research could be a beneficial solution for the promising design of advanced low speed flying vehicles.


2019 ◽  
Vol 36 (2) ◽  
pp. 157-173
Author(s):  
David E. Ashpis ◽  
Douglas R. Thurman

Abstract We address requirements for laboratory testing of AC Dielectric Barrier Discharge (AC-DBD) plasma actuators for active flow control in aviation gas turbine engines. The actuator performance depends on the gas discharge properties, which, in turn, depend on the pressure and temperature. It is technically challenging to simultaneously set test-chamber pressure and temperature to the flight conditions. We propose that the AC-DBD actuator performance depends mainly on the gas density, when considering ambient conditions effects. This enables greatly simplified testing at room temperature with only chamber pressure needing to be set to match the density at flight conditions. For turbine engines, we first constructed generic models of four engine thrust-classes; 300-, 150-, 50-passenger, and military fighter, and then calculated the densities along the engine at sea-level takeoff and altitude cruise conditions. The range of chamber pressures that covers all potential applications was found to be from 3 to 1256 kPa (0.03 to 12.4 atm), depending on engine-class, flight altitude, and actuator placement in the engine. The engine models are non-proprietary and can be used as reference data for evaluation requirements of other actuator types and for other purposes. We also provided examples for air vehicles applications up to 19,812 m (65,000 ft).


2018 ◽  
Vol 140 (10) ◽  
Author(s):  
F. F. Rodrigues ◽  
J. C. Pascoa ◽  
M. Trancossi

Dielectric barrier discharge (DBD) plasma actuators have several applications within the field of active flow control. Separation control, wake control, aircraft noise reduction, modification of velocity fluctuations, or boundary layer control are just some examples of their applications. They present several attractive features such as their simple construction, very low mass, fast response, low power consumption, and robustness. Besides their aerodynamic applications, these devices have also possible applications within the field of heat transfer, for example film cooling applications or ice formation prevention. However, due to the extremely high electric fields in the plasma region and consequent impossibility of applying classic intrusive techniques, there is a relative lack of information about DBDs thermal characteristics. In an attempt to overcome this scenario, this work describes the thermal behavior of DBD plasma actuators under different flow conditions. Infra-red thermography measurements were performed in order to obtain the temperature distribution of the dielectric layer and also of the exposed electrode. During this work, we analyzed DBD plasma actuators with different dielectric thicknesses and also with different dielectric materials, whose thermal behavior is reported for the first time. The results allowed to conclude that the temperature distribution is not influenced by the dielectric thickness, but it changes when the actuator operates under an external flow. We also verified that, although in quiescent conditions the exposed electrode temperature is higher than the plasma region temperature, the main heat energy dissipation occurs in the dielectric, more specifically in the plasma formation region.


Author(s):  
Takayuki Matsunuma ◽  
Takehiko Segawa

Tip leakage flow through the small gap between the blade tip of a turbine and the casing endwall reduces the aerodynamic performance. String-type dielectric barrier discharge (DBD) plasma actuators made of silicone printed-circuit board were used for the active control of the tip leakage flow of a linear turbine cascade. Sinusoidal voltage excitation with amplitude varying from 4 kV to 6 kV (peak-to-peak voltage: 8 kVp-p to 12 kVp-p) and fixed frequency of 10 kHz was applied to the plasma actuators. The two-dimensional velocity field in the blade passage was estimated by particle image velocimetry (PIV) under the very low Reynolds number conditions of Re = 7.1 × 103 and 1.42 × 104. The tip leakage flow was reduced by the flow control using plasma actuators. The high turbulence intensity region caused by the tip leakage flow was also reduced. For the quantitative comparisons, the displacement thickness of the absolute velocity distributions was examined. By the flow control of the plasma actuators, the displacement thickness at tip-side gradually decreased as the input voltage increased. Although three types of plasma actuators were used, with thin, thick, and flat electrodes and different ratios of discharge area, the differences in their effect were negligible. The reason for these very small differences in effect is the wide spread of the plasma discharge from the encapsulated electrode in the plasma actuator to the exposed electrode of the blade tip. At the relatively high Reynolds number condition of Re = 1.42 × 104, the effect of the plasma actuator was smaller than that at the lower Reynolds number condition of Re = 7.1 × 103.


Sign in / Sign up

Export Citation Format

Share Document