scholarly journals Simultaneous estimation of ledipasvir and sofosbuvir in bulk and its dosage forms by stability indicating RP-HPLC method

2019 ◽  
Vol 10 (3) ◽  
pp. 1631-1639
Author(s):  
Ismail Y ◽  
Vijaya Vara Prasad M

The fixed-dose ledipasvir-sofosbuvir combination offers an effective and well-tolerated pill for the treatment of chronic hepatitis C infection. Only a few analytical works were carried out to estimate the Ledipasvir and Sofosbuvir drug combination in the various dosage forms. This work aimed to simplify the estimation process using RP-HPLC methodology. The method was developed on a reversed phase Agilent C18 (4.6 x 150 mm, 5 µm) column. The isocratic elution process was performed using a mobile phase ratio of Methanol (70% v/v): Water (30 % v/v) with 0.6 ml/min flow rate. Elute was scanned using the PDA detector at the wavelength of 235 nm. The results of the elution process showed that the Ledipasvir and Sofosbuvir elute the peak at a concentration of 9 μg/ml and 40 μg/ml with retention times of 7.745 min and 2.345 min respectively. The percentage purity of Ledipasvir and Sofosbuvir was found to be 99.40 % w/v and 98.20 % w/v. The proposed method was found to be a high degree of precision and reproducibility. The percentage recovery was found to be 99.92 % for Ledipasvir and 99.82 % for Sofosbuvir. The LOD and LOQ were measured, and the results were within limits. The developed validation method can be applied for degradation evaluation of Ledipasvir and Sofosbuvir for the various dosage forms.


2013 ◽  
Vol 11 (2) ◽  
pp. 157-163
Author(s):  
Md Akteruzzaman ◽  
Asma Rahman ◽  
Md Zakir Sultan ◽  
Farhana Islam ◽  
Md Abdus Salam ◽  
...  

The objective of this study was to develop a simple, efficient, precise and accurate reversed phase HPLC (RP-HPLC) method for simultaneous determination of metformin in combination with rosiglitazone in newly formulated tablets. The combination of these drugs are commonly used and prescribed as anti-diabetic drugs in Bangladesh. The method has been developed by using the mobile phase comprising of sodium dihydrogen phosphate (NaH2PO4) buffer (pH 3.5) and acetonitrile (60:40, v/v) at a flow rate of 0.7 ml/min over C18 bonded silica column (ODS) (250 x 4.6 mm, 5 ?) at ambient temperature. The effluents were monitored at 230 nm and retention times were found to be 3.35 min and 11.95 min for metformin and rosiglitazone, respectively. Calibration curves were determined with a range from 0.03125 to 0.50 ?mole/ml of standards and the regression coefficients (r2) were found as 0.999 for metformin and 1.0 for rosiglitazone. The assay was validated for the accuracy, precision etc. according to ICH, USP and FDA guidelines. The proposed method can be useful in routine analysis for quantitative determination of metformin hydrochloride and rosiglitazone in pharmaceutical dosage forms. DOI: http://dx.doi.org/10.3329/dujps.v11i2.14574 Dhaka Univ. J. Pharm. Sci. 11(2): 157-163, 2012 (December)



2020 ◽  
Vol 32 (1) ◽  
pp. 16-21 ◽  
Author(s):  
Mahmoud M. Sebaiy ◽  
Sobhy M. El-Adl ◽  
Mohamed M. Baraka ◽  
Amira A. Hassan

An isocratic reversed-phase high-performance liquid chromatography (RP-HPLC) method has been developed for rapid and simultaneous separation and estimation of 3 antidiabetic drugs, namely, metformin, pioglitazone, and glimepiride, in human plasma within 3 min. Separation was carried out on a MAGELLEN 5U C18 (5 μm, 150 mm × 4.60 mm) using a mobile phase of MeOH–0.025 M KH2PO4 adjusted to pH 3.20 using ortho-phosphoric acid (85:15, v/v) at ambient temperature. The flow rate was 1 mL/min, and the maximum absorption was measured at 235 nm. The retention time of metformin, pioglitazone, and glimepiride was noted to be 1.24, 2.32, and 2.77 min, respectively, indicating a very short analysis time compared to that of other reported methods. Also, limits of detection were reported to be 0.05, 0.26, and 0.10 μg/mL for metformin, pioglitazone, and glimepiride, respectively, showing a high degree of method sensitivity. The method was then validated according to the FDA guidelines for the determination of the three drugs clinically in human plasma, in particular, regarding pharmacokinetic and bioequivalence simulation studies.



2010 ◽  
Vol 60 (2) ◽  
pp. 197-205 ◽  
Author(s):  
Dipti Patel ◽  
Natubhai Patel

Validated RP-HPLC and TLC methods for simultaneous estimation of tamsulosin hydrochloride and finasteride in combined dosage formsReversed-phase high-performance liquid chromatography (RP-HPLC) and thin-layer chromatography (TLC) methods have been developed and validated for simultaneous estimation of tamsulosin hydrochloride and finasteride in bulk drug and in combined dosage forms. RP-HPLC separation was achieved on a Phenomenex C18column using methanol/0.02 mol L-1ammonium acetate buffer/triethylamine (79.9 + 20 + 0.1,V/V/V) (pH 9.2) as mobile phase. TLC separation was achieved on an aluminium-backed layer of silica gel 60 F254using toluene/methanol/triethylamine (9 + 1.5 + 1,V/V/V) as eluent. Quantification was achieved with photodiode array (PDA) detection at 235 nm over the concentration range 0.5-16 and 1-50 μg mL-1with mean recovery of 99.8 ± 0.9 and 100.0 ± 0.8% for tamsulosin hydrochloride and finasteride, respectively, by the RP-HPLC method. Quantification was achieved with UV detection at 270 nm over the concentration range 100-2000 ng per spot and 250-5000 ng per spot with mean recovery of 98.9 ± 0.9 and 99.6 ± 0.7 % for tamsulosin hydrochloride and finasteride, respectively, by the TLC method. Both methods are simple, precise, accurate and sensitive and are applicable to the simultaneous determination of tamsulosin hydrochloride and finasteride in bulk drug and in combined dosage forms.



2018 ◽  
Vol 14 (4) ◽  
pp. 412-418
Author(s):  
Rasmita Patra ◽  
Prakash Narayana Reddy ◽  
N.S. Sampath Kumar ◽  
Vijaya R. Dirisala


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 59-68
Author(s):  
H Mahajan ◽  
S Savale ◽  
P Nerkar ◽  

The present study was aimed at developing a Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) method for simultaneous determination of curcumin (CRM) and gefitinib (GFT) in bulk, plasma and brain homogenate. hydrochlorothiazide was used as an internal standard (IS). A new simple, rapid, selective, precise and accurate RP-HPLC method has been developed. The separation was achieved by using C-18 column (Qualisil BDS C18, 250 mm x 4.6 mm I.D.) coupled with a guard column of silica, mobile phase consisted of acetonitrile: water with 0.1% formic acid (30:70 v/v). The flow rate was 0.2 ml/min and the drug was detected using PDA detector at the wavelength of 242 nm. The experimental conditions, including the diluting solvent, mobile phase composition, column saturation and flow rate, were optimised to provide high-resolution and reproducible peaks. The method was developed and tested for linearity range of 10-60 μg/mL for bulk analysis and 200-800 ng/mL for plasma and brain homogenate. The developed method was validated as per ICH guidelines, in terms of linearity, application of the proposed method to bulk sample, recovery, precision, repeatability, ruggedness, sensitivity (LOD and LOQ) and robustness and stability study (short and long-term stabilities, freeze/thaw stability, post-preparative). The low value of % RSD showed that the method was precise within the acceptance limit of 2%. The developed method was successfully applied for the analysis of the drug in bulk as well as various marketed formulation and drug in plasma and brain distribution studies.



Author(s):  
Bijithra Cholaraja ◽  
Shanmugasundaram P ◽  
Ragan G ◽  
Sankar Ask ◽  
Sumithra M

ABSTRACTObjective: To development and validation of a reversed-phase high-performance liquid chromatography (RP-HPLC) for the determination of modafinilin bulk and pharmaceutical dosage forms.Methods: A simple, precise, rapid, and accurate RP-HPLC method was developed for the estimation of modafinil in bulk and pharmaceutical dosageforms. Xterra RP 18 (250 mm × 4.6 mm, 5 µ particle size) with a mobile phase consisting of methanol:water 70:30 V/V was used. The flow rate1.0 ml/min and the effluents were monitored at 260 nm. The retention time and recovery time was 12 minutes. The detector response was linear inthe concentration of 10-50 µg/ml. The respective linear regression equation being Y=452.1x+65237. The limit of detection and limit of quantificationwere 4.547 and 1.377 mcg, respectively. The method was validated by determining its accuracy, precision, and system suitability.Result: The objective of the present work is to develop simple, precise, and reliable HPLC method for the analysis of modafinil in bulk andpharmaceutical dosage forms. This is achieved using the most commonly employed Xterra RP 18 (250 mm × 4.6 mm, 5 μ particle size) columndetection at 260 nm. The present method was validated according to ICH guidelines.Conclusion: In this study, a simple, fast and reliable HPLC method was developed and validated for the determination of modafinil in pharmaceuticalformulations.Keywords: Modafinil, Reversed-phase high-performance liquid chromatography, Estimation, ICH guidelines, Tablets. 



1970 ◽  
Vol 3 (1) ◽  
pp. 49-53 ◽  
Author(s):  
Gaurav Patel ◽  
Sanjay Patel ◽  
Dhamesh Prajapiti ◽  
Rajendra Mehta

A reverse phase high performance liquid chromatographic (RP-HPLC) method has been developed for the simultaneous estimation of Amlodipine Besylate and Hydrochlorothiazide in combine dosage form. Amlodipine Besylate (AML) is a long acting calcium channel blocker and in the treatment of CVS disorder. Hydrochlorothiazide (HCT) is a diuretic and antihypertensive. The mobile phase used was a combination of Water: Methanol (70:30). The detection of the combined dosage form was carried out at 245nm and a flow rate employd was 0.5ml/min. The retention time for Amlodipine Besylate and Hydrochlorothiazide was found to be 6.95 and 2.65 min respectively. Linearity was obtained in the concentration range of 6 to 18μg/ml of Amlodipine Besylate and 6 to 18μg/ml of Hydrochlorothiazide with a correlation coefficient of 0.997 and 0.9974. Detector consists of photodiode array detector; the reversed phase column used was RP-C18 (5 μm size, 250mm, 4.6mm i.d.) at ambient temperature. The developed method was validated according to ICH guidelines and values of accuracy, precision and other statistical analysis were found to be in good accordance with the prescribed values. Thus the proposed method is precise, selective and rapid for simultaneous estimation of Amlodipine Besylate and Hydrochlorothiazide in routine analysis. Key Words: Simultaneous Estimation; Amlodipine Besylate; Hydrochlorothiazide; HPLC. DOI: 10.3329/sjps.v3i1.6798S. J. Pharm. Sci. 3(1): 49-53



Sign in / Sign up

Export Citation Format

Share Document