scholarly journals Effect of positioning on physiological parameters on low birth weight preterm babies in neonatal intensive care unit

2019 ◽  
Vol 10 (4) ◽  
pp. 2800-2804 ◽  
Author(s):  
Alice Jeba J ◽  
Senthil Kumar S ◽  
Shivaprakash sosale

Preterm infants are babies who are delivered before the completion of 37 weeks gestation period. They are born with immature functioning of the brain. In  Neonatal Intensive Care Unit (NICU), these infants receives many environmental stimuli, and their comfort will be disturbed. These various sensory stimulus received in NICU influence the functional and neurodevelopmental outcome of these infants and also their quality of life. So this study was intended to evaluate the axillary temperature, heart rate, respiratory rate and oxygen saturation level of these infants prior to nesting and after nesting at the 60th minute. Forty preterm infants who fulfilled the criteria of selection were included in the study by simple random sampling and segregated into case and control groups by blocked randomization. Data was collected and recorded. The temperature was recorded by a digital thermometer, respiratory rate was counted by the number of times the infants' chest rises, heart rate and oxygen saturation readings from the pulse oximeter. The result of the study showed that there was statistically significant effect of nesting at 60th minute, temperature (t=5.03966,p<0.05), respiratory rate(t= -2.13,p<0.05) and heart rate (t=-2.59766,p<0.05). But the effect was not significant on oxygen saturation level (t=1.2,p=0.238).  Hence this study result supports the use of nesting in NICU.

2018 ◽  
Vol 4 (5) ◽  
pp. 457-461
Author(s):  
Dina Sulviana Damayanti ◽  
Djauhar Ismail ◽  
Warsiti Warsiti

Background: Preterm infants are at risk for respiratory and hypothermia disorders that may affect physiologic growth and development processes that can be aggravated by treatment processes while in the neonatal intensive care unit. Treatment in the NICU can trigger stress that can affect the vital signs and healing process of preterm infants, thus requiring non-medical treatment to stimulate the condition. This research provides a different treatment of sound therapy that has never been given to preterm infants in previous studies by listening murottal Al-Qur'an.Objective: To examine the effect of listening to the murottal Qur'an on oxygen saturation in preterm infants during treatment at the neonatal intensive care unit (NICU).Method: This was a pre-experimental study with one group pretest-postest design from September to October 2017. The samples were 30 preterm infants treated at NICU of the General Hospital of Panembahan Senopati Bantul selected using accidental sampling. The analysis used was simple linear regression.Result: There was an increase of the oxygen saturation level after given intervention of Murottal Qur'an for 3 days. The first day of oxygen saturation intervention increased by 2.07%, the second day 3.75%, and the third day 4.65% compared to the oxygen saturation level before the intervention.Conclusion: Listening to murrotal Qur'an could statistically increase oxygen saturation, but clinically there was no significant change in preterm infants, as the increase of oxygen saturation level was still within normal limits.


2019 ◽  
Vol 126 (1) ◽  
pp. 202-213 ◽  
Author(s):  
Rohan Joshi ◽  
Deedee Kommers ◽  
Xi Long ◽  
Loe Feijs ◽  
Sabine Van Huffel ◽  
...  

In preterm infants, a better understanding and quantification of cardiorespiratory coupling may help improve caregiving by enabling the tracking of maturational changes and subclinical signatures of disease. Therefore, in a study of 20 preterm infants admitted to a neonatal intensive care unit, we analyzed the cardiac and respiratory regulatory mechanisms as well as the coupling between them. In particular, we selectively analyzed coupling from changes in heart rate to respiratory oscillations as well as coupling from respiratory oscillations to the heart rate. Furthermore, we stratified this coupling based on decelerations and accelerations of the heart rate and by inspiration and expiration during respiration while contrasting periods of kangaroo care, an intervention known to enhance autonomic regulation, with periods in the incubator. We identified that preterm infants exhibit cardiorespiratory coupling that is nonsymmetric with regard to the direction of coupling. We demonstrate coupling from decelerations and accelerations of the heart rate to exhalation and inhalation, respectively, both on a beat-to-beat basis as well as with sustained decelerations and accelerations. On the other hand, on average, we also observed coupling from both inspiration and expiration to marginal decelerations in the heart rate. These phenomena, especially coupling from the changes in the heart rate to respiratory oscillations, were sensitive to whether the infant was receiving kangaroo care. NEW & NOTEWORTHY Preterm infants exhibit cardiorespiratory coupling that is nonsymmetric with regard to the direction of coupling; coupling from fluctuations in the heart rate to respiratory oscillations and vice versa are asymmetric. On average, coupling is observable from decelerations or accelerations in the heart rate to inhalation or exhalation, respectively, whereas, on average, both peaks and troughs of respiration exhibit coupling to marginal decelerations in the heart rate.


2017 ◽  
Vol 103 (5) ◽  
pp. F430-F435 ◽  
Author(s):  
Henriëtte Anje van Zanten ◽  
Steffen C Pauws ◽  
Ben J Stenson ◽  
Frans J Walther ◽  
Enrico Lopriore ◽  
...  

BackgroundFollowing recent recommendations, the oxygen saturation (SpO2) target range for preterm infants in our nursery was narrowed towards the higher end from 85%–95% to 90%–95%. We determined the effect of narrowing the SpO2 target range on the compliance in target range and distribution of SpO2 in preterm infants.MethodsBefore and after changing the target range from 85%–95% to 90%–95%, infants <30 weeks of gestation receiving oxygen were compared during their admission on the neonatal intensive care unit. For each infant, distribution of SpO2 was noted by collecting SpO2 samples each minute, and the percentage of time spent with SpO2 within 90%–95% was calculated. Oxygen was manually adjusted. Hypoxaemic events (SpO2 <80%) where oxygen was titrated were analysed.ResultsData were analysed for 104 infants (57 before and 47 after the range was narrowed). The narrower range was associated with an increase in the median (IQR) SpO2 (93% (91%–96%) vs 94% (92%–97%), p=0.01), but no increase in median time SpO2 within 90%–95% (49.2% (39.6%–59.7%) vs (46.9% (27.1%–57.9%), p=0.72). The distribution of SpO2 shifted to the right with a significant decrease in SpO2 <90%, but not <80%. The count of minute values for Sp02 <80% decreased, while the frequency and duration of hypoxaemic events and oxygen titration were not different.ConclusionNarrowing the target range from 85%–95% to 90%–95% in preterm infants was associated with an increase in median SpO2 and a rightward shift in the distribution, but no change in time spent between 90% and 95%.


2020 ◽  
Vol 68 (1) ◽  
Author(s):  
Reem M. Soliman ◽  
Fatma Alzahraah Mostafa ◽  
Antoine Abdelmassih ◽  
Elham Sultan ◽  
Dalia Mosallam

Abstract Background Patent ductus arteriosus poses diagnostic and therapeutic dilemma for clinicians, diagnosis of persistent PDA, and determination of its clinical and hemodynamic significance are challenging. The aim of this study is to determine the prevalence of PDA in preterm infants admitted to our NICU, to report cardiac and respiratory complications of PDA, and to study the management strategies and their subsequent outcomes. Result Echocardiography was done for 152 preterm babies admitted to neonatal intensive care unit (NICU) on day 3 of life. Eighty-seven (57.2%) preterms had PDA; 54 (62.1%) non-hemodynamically significant PDA (non-hsPDA), and 33 (37.9%) hemodynamically significant PDA. Hemodynamically significant PDA received medical treatment (paracetamol 15 mg/kg/6 h IV for 3 days). Follow-up echocadiography was done on day 7 of life. Four babies died before echo was done on day 7. Twenty babies (68.9%) achieved closure after 1st paracetamol course. Nine babies received 2nd course paracetamol. Follow-up echo done on day 11 of life showed 4 (13.7%) babies achieved successful medical closure after 2nd paracetamol course; 5 babies failed closure and were assigned for surgical ligation. The group of non-hsPDA showed spontaneous closure after conservative treatment. Pulmonary hemorrhage was significantly higher in hsPDA group. Mortality was higher in hsPDA group than non-hsPDA group. Conclusion Echocardiographic evaluation should be done for all preterms suspected clinically of having PDA. We should not expose vulnerable population of preterm infants to medication with known side effects unnecessarily; we should limit medical closure of PDA to hsPDA. Paracetamol offers several important therapeutic advantages options being well tolerated and having more favorable side effects profile.


Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 999
Author(s):  
Henry Dore ◽  
Rodrigo Aviles-Espinosa ◽  
Zhenhua Luo ◽  
Oana Anton ◽  
Heike Rabe ◽  
...  

Heart rate monitoring is the predominant quantitative health indicator of a newborn in the delivery room. A rapid and accurate heart rate measurement is vital during the first minutes after birth. Clinical recommendations suggest that electrocardiogram (ECG) monitoring should be widely adopted in the neonatal intensive care unit to reduce infant mortality and improve long term health outcomes in births that require intervention. Novel non-contact electrocardiogram sensors can reduce the time from birth to heart rate reading as well as providing unobtrusive and continuous monitoring during intervention. In this work we report the design and development of a solution to provide high resolution, real time electrocardiogram data to the clinicians within the delivery room using non-contact electric potential sensors embedded in a neonatal intensive care unit mattress. A real-time high-resolution electrocardiogram acquisition solution based on a low power embedded system was developed and textile embedded electrodes were fabricated and characterised. Proof of concept tests were carried out on simulated and human cardiac signals, producing electrocardiograms suitable for the calculation of heart rate having an accuracy within ±1 beat per minute using a test ECG signal, ECG recordings from a human volunteer with a correlation coefficient of ~ 87% proved accurate beat to beat morphology reproduction of the waveform without morphological alterations and a time from application to heart rate display below 6 s. This provides evidence that flexible non-contact textile-based electrodes can be embedded in wearable devices for assisting births through heart rate monitoring and serves as a proof of concept for a complete neonate electrocardiogram monitoring system.


Sign in / Sign up

Export Citation Format

Share Document