Capabilitites of gamma(spectrometry methods for on(line monitoring of nitride SNF pyrochemical reprocessing

2018 ◽  
Vol 2018 (2) ◽  
pp. 78-88
Author(s):  
Boris Andreevich Kanashov ◽  
Smirnov V.P. Smirnov ◽  
Vladimir Valerievich Kadilin ◽  
Renat Faridovich Ibragimov ◽  
Grigory Leonidovich Dedenko ◽  
...  
1982 ◽  
Vol 71 (1-2) ◽  
pp. 253-264 ◽  
Author(s):  
H. R. Wilde ◽  
W. Herzog

1975 ◽  
Vol 47 (1) ◽  
pp. 75-79 ◽  
Author(s):  
Dale G. Olson ◽  
Michael S. Cole

2018 ◽  
Vol 4 (3) ◽  
pp. 211-215
Author(s):  
Boris Kanashov ◽  
Valery Smirnov ◽  
Vladimir Kadilin ◽  
Renat Ibragimov ◽  
Grigory Dedenko ◽  
...  

The paper reports the first test results for detectors of various types and equipment of gamma-spectrometry channels under external radiation originating from pyrochemical reprocessing of spent mixed nitride uranium-plutonium (MNUP) fuel. Testing was carried out on a solid-state detector with a CdZnTe crystal, a scintillation detector with a LaBr3crystal, and an ionization chamber based on compressed xenon. Simulated external gamma-radiation was created by means of a Co-based scattered gamma-radiation source. The paper also describes an experimental facility and a measurement technique, and presents the facility testing results for the above three detectors. The solid-state detector was proved to have the best performance. However, achieving the design characteristics of the gamma-spectrometry channel requires new solutions for protection and collimation of gamma-radiation produced by a real MNUP SNF reprocessing facility. What is meant here is the influence of the detectors’ geometry on the configuration of the protective collimator which is proposed to be used in real conditions. Thus, if a Xe-based detector is used, the calculated mass of the protective collimator is 900 kg, while it is possible to use less massive protection for the other detectors. In addition, when manufacturing neutron shielding for detectors based on CdZnTe and LaBr3, it is necessary to consider the neutron radiation factor in MNUP SNF processing. It is possible to surround the collimator with a moderating layer (for example, polyethylene) and create inside it a skin from a thermal neutron absorber (for example, based on cadmium).


Author(s):  
William Krakow

In the past few years on-line digital television frame store devices coupled to computers have been employed to attempt to measure the microscope parameters of defocus and astigmatism. The ultimate goal of such tasks is to fully adjust the operating parameters of the microscope and obtain an optimum image for viewing in terms of its information content. The initial approach to this problem, for high resolution TEM imaging, was to obtain the power spectrum from the Fourier transform of an image, find the contrast transfer function oscillation maxima, and subsequently correct the image. This technique requires a fast computer, a direct memory access device and even an array processor to accomplish these tasks on limited size arrays in a few seconds per image. It is not clear that the power spectrum could be used for more than defocus correction since the correction of astigmatism is a formidable problem of pattern recognition.


Author(s):  
A.M.H. Schepman ◽  
J.A.P. van der Voort ◽  
J.E. Mellema

A Scanning Transmission Electron Microscope (STEM) was coupled to a small computer. The system (see Fig. 1) has been built using a Philips EM400, equipped with a scanning attachment and a DEC PDP11/34 computer with 34K memory. The gun (Fig. 2) consists of a continuously renewed tip of radius 0.2 to 0.4 μm of a tungsten wire heated just below its melting point by a focussed laser beam (1). On-line operation procedures were developped aiming at the reduction of the amount of radiation of the specimen area of interest, while selecting the various imaging parameters and upon registration of the information content. Whereas the theoretical limiting spot size is 0.75 nm (2), routine resolution checks showed minimum distances in the order 1.2 to 1.5 nm between corresponding intensity maxima in successive scans. This value is sufficient for structural studies of regular biological material to test the performance of STEM over high resolution CTEM.


Author(s):  
Neil Rowlands ◽  
Jeff Price ◽  
Michael Kersker ◽  
Seichi Suzuki ◽  
Steve Young ◽  
...  

Three-dimensional (3D) microstructure visualization on the electron microscope requires that the sample be tilted to different positions to collect a series of projections. This tilting should be performed rapidly for on-line stereo viewing and precisely for off-line tomographic reconstruction. Usually a projection series is collected using mechanical stage tilt alone. The stereo pairs must be viewed off-line and the 60 to 120 tomographic projections must be aligned with fiduciary markers or digital correlation methods. The delay in viewing stereo pairs and the alignment problems in tomographic reconstruction could be eliminated or improved by tilting the beam if such tilt could be accomplished without image translation.A microscope capable of beam tilt with simultaneous image shift to eliminate tilt-induced translation has been investigated for 3D imaging of thick (1 μm) biologic specimens. By tilting the beam above and through the specimen and bringing it back below the specimen, a brightfield image with a projection angle corresponding to the beam tilt angle can be recorded (Fig. 1a).


Author(s):  
G.Y. Fan ◽  
J.M. Cowley

In recent developments, the ASU HB5 has been modified so that the timing, positioning, and scanning of the finely focused electron probe can be entirely controlled by a host computer. This made the asynchronized handshake possible between the HB5 STEM and the image processing system which consists of host computer (PDP 11/34), DeAnza image processor (IP 5000) which is interfaced with a low-light level TV camera, array processor (AP 400) and various peripheral devices. This greatly facilitates the pattern recognition technique initiated by Monosmith and Cowley. Software called NANHB5 is under development which, instead of employing a set of photo-diodes to detect strong spots on a TV screen, uses various software techniques including on-line fast Fourier transform (FFT) to recognize patterns of greater complexity, taking advantage of the sophistication of our image processing system and the flexibility of computer software.


Author(s):  
John F. Mansfield ◽  
Douglas C. Crawford

A method has been developed that allows on-line measurement of the thickness of crystalline materials in the analytical electron microscope. Two-beam convergent beam electron diffraction (CBED) patterns are digitized from a JEOL 2000FX electron microscope into an Apple Macintosh II microcomputer via a Gatan #673 CCD Video Camera and an Imaging Systems Technology Video 1000 frame-capture board. It is necessary to know the lattice parameters of the sample since measurements are made of the spacing of the diffraction discs in order to calibrate the pattern. The sample thickness is calculated from measurements of the spacings of the fringes that are seen in the diffraction discs. This technique was pioneered by Kelly et al, who used the two-beam dynamic theory of MacGillavry relate the deviation parameter (Si) of the ith fringe from the exact Bragg condition to the specimen thickness (t) with the equation:Where ξg, is the extinction distance for that reflection and ni is an integer.


Author(s):  
W.J. de Ruijter ◽  
P. Rez ◽  
David J. Smith

There is growing interest in the on-line use of computers in high-resolution electron n which should reduce the demands on highly skilled operators and thereby extend the r of the technique. An on-line computer could obviously perform routine procedures hand, or else facilitate automation of various restoration, reconstruction and enhan These techniques are slow and cumbersome at present because of the need for cai micrographs and off-line processing. In low resolution microscopy (most biologic; primary incentive for automation and computer image analysis is to create a instrument, with standard programmed procedures. In HREM (materials researc computer image analysis should lead to better utilization of the microscope. Instru (improved lens design and higher accelerating voltages) have improved the interpretab the level of atomic dimensions (approximately 1.6 Å) and instrumental resolutior should become feasible in the near future.


Sign in / Sign up

Export Citation Format

Share Document