scholarly journals MODELING OF CHARGE TRANSPORT IN THE ACTIVE VOLUME OF THE IONIZATION FISSION CHAMBER IN CURRENT MODE

Author(s):  
Le Thi Dieu Hien ◽  
A. A. Khrutchinsky ◽  
S. A. Kuten
2021 ◽  
Vol 24 (4) ◽  
pp. 329-337
Author(s):  
A. A. Khrushchinsky ◽  
S. A. Kuten

The question of the spatial distribution of ion pairs created by 235U fission fragments in the active volume of the fission chamber has been studied. The formulas of the spatial distribution of ion pairs in cylindrical fission chambers are proposed, which allows you to evaluate correctly the density of ion pairs in any point in the sensitive volume of the fission chamber


2020 ◽  
Vol 231 ◽  
pp. 05009
Author(s):  
Shakir Zeinalov ◽  
Olga Sidorova ◽  
Pavel Sedyshev ◽  
Valery Shvetsov ◽  
Youngseok Lee ◽  
...  

In thermal nuclear reactors, most of the power is generated by thermal neutron induced fission. Therefore, fission chambers with targets that respond directly to slow neutrons are of great interest for thermal neutron flux measurements due to relatively low sensitivity to gamma radiation. However, the extreme conditions associated with experiments at very low cross section demand highly possible thermal neutron flux, leading often to substantial design changes. In this paper we report design of a fission chamber for wide range (from 10 to 1012 n/cm2 sec) measurement of thermal neutron flux. Test experiments were performed at the first beam of IBR2 pulsed reactor using digital pulse processing (DPP) technique with modern waveform digitizers (WFD). The neutron pulses detected by the fission chamber in each burst (5 Hz repetition rate) of the reactor were digitized and recorded to PC memory for further on-line and off-line analysis. New method is suggested to make link between the pulse counting, the current mode and the Campbell technique.


2021 ◽  
Vol 253 ◽  
pp. 04015
Author(s):  
Danilo Bisiach ◽  
Loïc Barbot ◽  
Grégoire De Izarra ◽  
Christophe Destouches ◽  
Manuel Cargnelutti ◽  
...  

Fission chambers are widely used in nuclear reactors, either occasionally to probe the neutron flux maps in nuclear power plants or as part of the nuclear instrumentation used in research reactors to characterize neutron flux levels in irradiation locations. Wide dynamic range acquisition systems are very limited in the nuclear instrumentation market. Thus, since 2012, CEA is developing the MONACO system, which allows measurement in pulse, fluctuation, and current mode running simultaneously on the same channel. The simultaneous use of three measurement modes places high requirements on the amplification stage. Indeed, the current mode exploits a bandwidth between 0 and a few kHz, while the fluctuation mode is based on the frequency range of 100 kHz 1MHz. Finally, for the pulse mode, it is necessary to identify current pulses of a few uA in amplitude and with a duration of about ten nanoseconds, which implies a bandwidth that extends up to 10 or 20 MHz. In the frame of the industrialization of the MONACO system, a new preamplifier was designed to meet those requirements. With a first prototype, LDCI and I-TECH performed very promising bench tests in October 2020. Tests with synthetic signals corresponding to pulse and fluctuation mode showed very good performance of the electronics. The positive and negative current pulses are correctly amplified and the measurement noise was estimated at 0.1 µApp thanks to proper electronic shielding. The DC measurement is also satisfactory in the tested range with an accuracy of less than nA and a bandwidth of 1kHz. Preamplifier qualifications are planned within realistic experiments using a fission chamber placed in a neutron field.


1990 ◽  
Vol 137 (2) ◽  
pp. 61 ◽  
Author(s):  
Chris Toumazou ◽  
John Lidgey ◽  
Brett Wilson

2018 ◽  
Vol 138 (5) ◽  
pp. 453-462
Author(s):  
Jun-ichi Itoh ◽  
Tomokazu Sakuraba ◽  
Hoai Nam Le ◽  
Hiroki Watanabe ◽  
Keisuke Kusaka

Sign in / Sign up

Export Citation Format

Share Document