Miconazole Nitrate Vaginal Suppositories

Keyword(s):  
2017 ◽  
Vol 14 (8) ◽  
Author(s):  
Andres Felipe Cartagena ◽  
Amanda Martinez Lyra ◽  
Aline Cristina Kapuchczinski ◽  
Amanda Migliorini Urban ◽  
Luis Antonio Esmerino ◽  
...  

2020 ◽  
Vol 66 (1) ◽  
pp. 23-29
Author(s):  
Octavia-Laura Moldovan ◽  
Diana-Nicoleta Brihan ◽  
Nicoleta Todoran ◽  
Aura Rusu

AbstractObjective: The compatibility of four binary active substances combinations adapalene – levofloxacin (ADP-LFX), adapalene – miconazole nitrate (ADP-MCZ), levofloxacin – meloxicam (LFX-MLX) and levofloxacin – miconazole nitrate (LFX-MCZ) was analysed to be comprised in new transdermal therapeutic systems. Also, the compatibility of selected active substances and four polymeric excipients (hydroxypropyl methyl-cellulose - HPMC 15000, hydroxypropyl methylcellulose - HPMC E5, ethyl cellulose - EC 10, and hydroxyethyl cellulose – HEC) was studied.Methods: Thin layer chromatographic method (TLC) and four selected mobile phases were used. On the plate (in situ) were obtained the binary combinations (active substances and active substance-polymer).Results: A good compatibility of ADP-LFX was found using ammonia : methanol : acetonitrile : methylene chloride 2:4:1:4 mobile phase. Using chloroform : acetone : glacial acetic acid 34:4:3 on the chromatogram of ADP-MCZ, only ADP spots appeared but without changes in the shape of the spots and Rf values. Any modifications of LFX and MLX spots (from LFX-MLX mixture) had been observed using toluene : glacial acetic acid : methanol 11:1:0.5 mobile phase, although LFX spots have remained on the baseline. Only LFX spots were visible from LFX-MLX and LFX-MCZ mixtures (ammonia : methanol : acetonitrile : methylene chloride 2:4:1:4 mobile phase). Distinctive spots were observed for ADP, LFX and MLX with variable results from no chemical interactions to limited chemical interactions when the compatibility with polymers was verified.Conclusions: ADP-LFX and LFX-MLX mixtures were found to be compatible. ADP with HPMC polymers and LFX with HPMC E5 and HEC had presented excellent compatibility; for the other binary combinations, different analytical methods will be necessary.


Author(s):  
Salem H ◽  
◽  
Omar MA ◽  
Derayea SM ◽  
Khalil AA ◽  
...  

A comparative study for the validation and advancement of two analytical approaches applied for the simultaneous determination of Mometasone Furoate (MF), Miconazole Nitrate (MIC) and Gentamicin (GM) formulated in Momenta® cream. The first approach was TLC-spectrodensitometric method, which was advanced by separating the three components on TLC aluminum plates coated with silica gel 60 F254 using chloroform: methanol: formic acid (4:0.3:0.15, v/v/v) as a mobile phase, then scanned at 254nm using Camage TLC scanner 3 operated in reflectance-absorbance mode. The second approach was the chemometric method using two models: Partial Least Squares (PLS) and Principle Component Regression Model (PCR). The proposed approaches were validated according to ICH guidelines and were applied for the determination of the ternary mixtures in their analytical mixtures and pharmaceutical preparation.


2011 ◽  
Vol 2011 ◽  
pp. 1-8 ◽  
Author(s):  
J. Ishwara Bhat ◽  
Vijaya D. P. Alva

The corrosion inhibition of mild steel by miconazole nitrate, an antifungal drug has been investigated using potentiodynamic polarization, electrochemical impedance spectroscopy technique, and weight loss methods. The experimental results suggested miconazole nitrate is a good corrosion inhibitor for mild steel in 1 M hydrochloric acid medium. The inhibition efficiency increased with increase in inhibitor concentration. The thermodynamic parameters were determined and discussed. The inhibition was assumed to occur via adsorption of the inhibitor molecule on the surface of mild steel following Langmuir adsorption isotherm.


2011 ◽  
Vol 52 (3) ◽  
pp. 229-237 ◽  
Author(s):  
Yoshihiro Sei ◽  
Megumi Kobayashi ◽  
Eri Soude
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document