Syndesmotic Fixation in Supination-External Rotation Ankle Fractures: A Prospective Randomized Study

2011 ◽  
Vol 32 (12) ◽  
pp. 1103-1109 ◽  
Author(s):  
Harri J. Pakarinen ◽  
Tapio E. Flinkkilä ◽  
Pasi P. Ohtonen ◽  
Pekka H. Hyvönen ◽  
Martti T. Lakovaara ◽  
...  
2005 ◽  
Vol 26 (12) ◽  
pp. 1038-1041 ◽  
Author(s):  
Ryan Finnan ◽  
Luke Funk ◽  
Michael S. Pinzur ◽  
Steven Rabin ◽  
Laurie Lomasney ◽  
...  

Background: While open reduction of displaced ankle fractures generally is accepted as the standard of care, relatively little is known about the health related quality of life after treatment. It is generally accepted that clinical results of treatment for supination-external rotation stage IV ankle fractures are favorable. The goal of this investigation was to determine the relationship between clinical results and health-related quality of life outcome measures in a consecutive series of patients treated for closed supination-external rotation stage IV ankle fractures. Methods: Twenty-six of 156 patients who had operative treatment for closed, displaced supination-external rotation stage IV ankle fractures during a 9-year period, completed the Short Musculoskeletal Function Assessment (SMFA) outcome questionnaire. Radiographs and clinical records were reviewed to determine quality of operative repair, postoperative morbidity, and the development of post-traumatic arthritis. Results: There were no postoperative complications. Of the 26 patients who returned the SMFA questionnaires, 19 had “good,” and seven had “fair” reduction of their fractures. Six showed radiographic evidence of arthritis at followup. Study participants reported scores that were similar to the general population in five of the six domains of the SMFA. Their scores in the mobility index were statistically less favorable (23.72 vs. 13.61, p = 0.016) when compared to the general population. Participants with “good” operative reductions and no evidence of arthritis at followup showed no significant difference to the general population. Participants with either a “fair” operative reduction or evidence of postoperative arthritis at followup had less favorable scores in the daily activities (mean 13.45 vs. 11.82, p = 0.004), mobility (43.43 vs. 13.61, p = 0.001), dysfunction (32.89 vs. 12.70, p = 0.014), and bother (35.80 vs. 13.77, p = 0.020) domains, when compared to the general population. Conclusions: The results of this investigation suggest that patients with excellent radiographic operative reductions and no arthritis as early as 6 months after surgery sustain no lasting unfavorable effect on health related quality of life. Patients with “fair” radiographic reduction, or presence of arthritis or both at followup, are likely to have a negative effect on their quality of life.


Injury ◽  
2019 ◽  
Vol 50 (7) ◽  
pp. 1382-1387 ◽  
Author(s):  
Dong-Il Chun ◽  
Jahyung Kim ◽  
Yoon Seok Kim ◽  
Jae-Ho Cho ◽  
Sung-Hun Won ◽  
...  

2018 ◽  
Vol 3 (3) ◽  
pp. 2473011418S0052
Author(s):  
Sohail Yousaf ◽  
Daniel Hay

Category: Trauma Introduction/Purpose: Differentiating stable isolated fibula fractures consistent with supination external rotation (SER) II ankle fractures from unstable SER IV fractures is essential in determining the need for surgical stabilisation. Stress radiographs are usually required to assess stability including gravity stress views (GSV) and external rotation views (ER). There is no clear consensus as to which modality is most useful to determine stability in a fracture clinic or emergency setting. In last, few years clinical uncertainty about the reliability has led researcher to focus on weight bearing radiographs (WB) .We aim to review recent literature regarding reliability of WB radiographs to estimate the stability of supination external rotation ankle fractures. Methods: A systematic review of the literature relating to radiological assessment of stability of supination external rotation ankle fractures was conducted according to PRISMA guidelines. The systematic review was prospectively registered with PROSPERO. It involved the following steps: Researching the question-Do weight bearing radiographs estimate the stability of an isolated distal fibula fracture? Setting inclusion and exclusion criteria-All English language articles published in the including any Randomised controlled trials (RCT’s) and cohort studies. Data collection)– A literature search of Medline (PubMed), the Cochrane Bone, Joint, and Muscle Trauma Group trial register, the Cochrane central register of controlled trials, Embase and CINAHL was undertaken. The grey literature was searched. Key terms ‘supination external rotation fracture’, ‘stability’. Other variations to the key words were ‘weight bearing’, “axial load”, ‘stress x-rays’, ‘systematic reviews’ and ‘meta-analysis’. Results: A total of six studies met the inclusion criteria including 601 patients. No previous systematic review on stress radiographs including weight bearing was published. All studies concluded weight bearing radiographs is an easy, pain-free, safe and reliable method to estimate stability of isolated distal fibula fractures. No serious concerns or complications were reported. Conclusion: The evidence base contained many methodological limitations and most of the evidence was either level III or IV, and so any conclusion drawn from the research must be done so with caution. The studies suggest that GSV overestimates the instability which should be assessed with studies should focus on randomized controlled trials with narrow range of clinically useful outcome measures.


2016 ◽  
Vol 45 (1) ◽  
pp. 210-217 ◽  
Author(s):  
Kaitlin C. Neary ◽  
Matthew A. Mormino ◽  
Hongmei Wang

Background: In stress-positive, unstable supination–external rotation type 4 (SER IV) ankle fractures, implant selection for syndesmotic fixation is a debated topic. Among the available syndesmotic fixation methods, the metallic screw and the suture button have been routinely compared in the literature. In addition to strength of fixation and ability to anatomically restore the syndesmosis, costs associated with implant use have recently been called into question. Purpose: This study aimed to examine the cost-effectiveness of the suture button and determine whether suture button fixation is more cost-effective than two 3.5-mm syndesmotic screws not removed on a routine postoperative basis. Study Design: Economic and decision analysis; Level of evidence, 2. Methods: Studies with the highest evidence levels in the available literature were used to estimate the hardware removal and failure rates for syndesmotic screws and suture button fixation. Costs were determined by examining the average costs for patients who underwent surgery for unstable SER IV ankle fractures at a single level-1 trauma institution. A decision analysis model that allowed comparison of the 2 fixation methods was developed. Results: Using a 20% screw hardware removal rate and a 4% suture button hardware removal rate, the total cost for 2 syndesmotic screws was US$20,836 and the total effectiveness was 5.846. This yielded a total cost of $3564 per quality-adjusted life-year (QALY) over an 8-year time period. The total cost for suture button fixation was $19,354 and the total effectiveness was 5.904, resulting in a total cost of $3294 per QALY over the same time period. A sensitivity analysis was then conducted to assess suture button fixation costs as well as screw and suture button hardware removal rates. Other possible treatment scenarios were also examined, including 1 screw and 2 suture buttons for operative fixation of the syndesmosis. To become more cost-effective, the screw hardware removal rate would have to be reduced to less than 10%. Furthermore, fixation with a single suture button continued to be the dominant treatment strategy compared with 2 suture buttons, 1 screw, and 2 screws for syndesmotic fixation. Conclusion: This cost-effectiveness analysis suggests that for unstable SER IV ankle fractures, suture button fixation is more cost-effective than syndesmotic screws not removed on a routine basis. Suture button fixation was a dominant treatment strategy, because patients spent on average $1482 less and had a higher quality of life by 0.058 QALYs compared with patients who received fixation with 2 syndesmotic screws. Assuming that functional outcomes and failure rates were equivalent, screw fixation only became more cost-effective when the screw hardware removal rate was reduced to less than 10% or when the suture button cost exceeded $2000. In addition, fixation with a single suture button device proved more cost-effective than fixation with either 1 or 2 syndesmotic screws.


Sign in / Sign up

Export Citation Format

Share Document