scholarly journals DEVELOPMENT OF HEAT PUMP MODEL BASED ON OUTLET TEMPERATURE OF HEAT MEDIUM

2017 ◽  
Vol 82 (735) ◽  
pp. 453-461
Author(s):  
Eisuke TOGASHI
2013 ◽  
Vol 805-806 ◽  
pp. 645-648
Author(s):  
Wei Xiu Shi ◽  
Li Sheng Pan

Under the situation of energy crisis, air source heat pumps are paid more attention recently. In order to save energy, the feasibility and performance of air source heat pump are studied by experiment, and variation laws of exhaust temperature, evaporator outlet temperature and outlet presser of compressor were analyzed in this paper. Air source heat pump apparatus were set up and the experiment was during 10°C, 20°C, 30°C and 40°C. The results were as follows: exhaust temperature of compressor increases gradually with the increase of tank temperature, but the temperature difference between exhaust temperature of compressor and tank temperature becomes little; temperature difference in evaporator decreases; Compressor outlet pressure increases obviously.


2012 ◽  
Vol 516-517 ◽  
pp. 1180-1183
Author(s):  
Hui Fan Zheng ◽  
Chun Li Yang ◽  
Yan Hua Li ◽  
Yao Hua Liang

An experimental setup is designed and built to study the operation characteristics of the air-cooled heat pump system for small residential in this paper. Based on the experimental setup, the characteristics of the energy efficiency ratio(EER) and cooling capacity have been researched when the outlet temperature of cooling water and outdoor environment temperature change. The experimental data demonstrate that the cooling capacity and EER of the system increases with increasing outlet cooling water temperatures and decreases with increasing outdoor environment temperatures. In addition, the correlation of the system EER is calculated by using the least square method based on the experimental data.


2013 ◽  
Vol 724-725 ◽  
pp. 909-915
Author(s):  
Ping Fang Hu ◽  
Zhong Yi Yu ◽  
Fei Lei ◽  
Na Zhu ◽  
Qi Ming Sun ◽  
...  

A vertical U-tube ground heat exchanger can be utilized to exchange heat with the soil in ground source heat pump systems. The outlet temperature of the working fluid through the U-tube not only accounts for heat transfer capacity of a ground heat exchanger, but also greatly affects the operational efficiency of heat pump units, which is an important characteristic parameter of heat transfer process. It is quantified by defining a thermal effectiveness coefficient. The performance evaluation is performed with a three dimensional numerical model using a finite volume technique. A dynamic simulation was conducted to analyze the thermal effectiveness as a function of soil thermal properties, backfill material properties, separation distance between the two tube legs, borehole depth and flow velocity of the working fluid. The influence of important characteristic parameters on the heat transfer performance of vertical U-tube ground heat exchangers is investigated, which may provide the references for the design of ground source heat pump systems in practice.


Author(s):  
Lin Fu ◽  
Xiling Zhao ◽  
Shigang Zhang ◽  
Yi Jiang ◽  
Hui Li ◽  
...  

It is well known that combined heating and power (CHP) generation permits the energy of the fuel to be more efficiently than electric and thermal separate generation. The paper deals with natural gas CHP system with a 70kWe gas-powered internal combustion engine (ICE), which has been set up at the Tsinghua University energy-saving building, in Beijing, China. The system is composed of an ICE, a flue gas heat exchanger and other heat exchangers. The conventional system’s characteristics is that the gas engine generates power on-site, and the exhaust of the gas engine is recovered by a high temperature flue gas-water heat exchanger, and the jacket water heat is recovered by a water-water heat exchanger to supply heat for district heating system. In order to improve the system’s performance, an innovative system with absorption heat pump is adopted. The exhaust of the gas engine drives an absorption heat pump to recover the flue gas sensible heat and further recover the latent heat, so the outlet temperature of the exhaust could be lowered to 50°C. In this paper, the electrical and thermal performance of the innovative system were tested and compared with conventional cogeneration systems. The test and comparison results show that the innovative CHP system could increase the heat utilization efficiency 10% in winter. All the results provide important insight into CHP performance characteristics and could be valuable references for CHP system’s improvements.


2019 ◽  
Vol 160 ◽  
pp. 106199 ◽  
Author(s):  
Shifang Huang ◽  
Xing Lu ◽  
Wangda Zuo ◽  
Xiaosong Zhang ◽  
Caihua Liang

Sign in / Sign up

Export Citation Format

Share Document