scholarly journals DESIGN CRITERIA ON ULTIMATE STRENGTH OF L-SHAPED STEEL BEAM-RC COLUMN JOINT AND STEEL BEAM-SRC COLUMN JOINT USING MECHANICAL ANCHORAGES

2013 ◽  
Vol 78 (689) ◽  
pp. 1281-1288
Author(s):  
Kiyoshi MASUO ◽  
Hiroyuki TAGAWA ◽  
Yukako ICHIOKA ◽  
Masato ADACHI
Author(s):  
Toshiro SUZUKI ◽  
Katsuki TAKIGUCHI ◽  
Hisato HOTTA ◽  
Masahiro KATO

Author(s):  
R. N. Croad ◽  
F. H. Mead ◽  
R. Shepherd

This paper is a summary of an investigation into the cyclic response
of a steel cruciform joint. A star plate beam to column joint identical
to one of those forming the frame of the pier structure at Auckland International Airport was tested at the University of Auckland, School of Engineering. In this paper both the preparations undertaken and the subsequent experimental programme are described. The results are analysed and the observed behaviour is discussed. Comparisons are made with recently proposed design criteria for steel beam to column connections, as well as with formulae for predicting the load-deflection curves. Conclusions are drawn on the suitability of these theories for response prediction of star plate geometry joints. Additionally the energy absorption capabilities of the joint are compared with results from earlier American research.


2012 ◽  
Vol 36 ◽  
pp. 325-336 ◽  
Author(s):  
Hong-Gun Park ◽  
Hyeon-Jong Hwang ◽  
Cheol-Ho Lee ◽  
Chang-Hee Park ◽  
Chang-Nam Lee

2010 ◽  
Vol 75 (655) ◽  
pp. 1727-1735 ◽  
Author(s):  
Yasushi NISHIMURA ◽  
Mikihito YOSHIDA ◽  
Keiichi SAITO ◽  
Naoki AOYAMA

Author(s):  
Ju-Yun Hu ◽  
Won-Kee Hong ◽  
Seon-Chee Park ◽  
Jisoon Kim

The authors proposed steel beam-column connections for precast concrete frames in previous studies. The steel-concrete composite frames provided fast assembly time as steels with economy of concrete structures. However, when enough space is not available at column-beam joints steel sections from beams cannot be connected with column brackets. This paper suggests that some vertical reinforcing bars are disconnected at joints by connecting vertical steel reinforcements to steel plates placed above and below column steels to provide load transferring path. Loads from re-bars are transferred to steel plates, column steels and back to steel plates and re-bars below column steels. Re-bars connected to steel plates by bolts at above and below column steel are discontinued at joint to provide spaces for connections between column brackets and beam steels. Extensive experiments were performed to verify load transfer from re-bars to steel plates above joints and steel plates to re-bars below joint. The flexural load bearing capacity of a column with total of 24 vertical re-bars were compared to columns with discontinuous re-bars at joints. The number of discontinuous re-bars at joint used in column specimen was 0 (0.0%), 4 (16.7%), 12 (50.0%), and 20 (83.3%). The numbers in parenthesis are the percentages of discontinuous rebars to the total number of vertical re-bars of control column. Experiments showed how loads from vertical steel reinforcements that were cut off at joints were transferred to steel plate. The test results also demonstrated that a part of flexural capacities were reduced for specimen with discontinuous vertical re-bars. The reduction of 6.0 %, 13.7% and 54.0% of flexural capacities were observed for columns with 4 (16.7%), 12 (50.0%) and 20 (83.3%) discontinuous vertical rebars, respectively. The test results can be used to design vertical reinforcing bars and column joints that can provide space for column brackets to which steel members of beams are connected.


Sign in / Sign up

Export Citation Format

Share Document