Biomechanical evaluation of a simulated T-9 burst fracture of the thoracic spine with an intact rib cage

2014 ◽  
Vol 21 (3) ◽  
pp. 481-488 ◽  
Author(s):  
Tiffany G. Perry ◽  
Prasath Mageswaran ◽  
Robb W. Colbrunn ◽  
Tara F. Bonner ◽  
Todd Francis ◽  
...  

Object Classic biomechanical models have used thoracic spines disarticulated from the rib cage, but the biomechanical influence of the rib cage on fracture biomechanics has not been investigated. The well-accepted construct for stabilizing midthoracic fractures is posterior instrumentation 3 levels above and 2 levels below the injury. Short-segment fixation failure in thoracolumbar burst fractures has led to kyphosis and implant failure when anterior column support is lacking. Whether shorter constructs are viable in the midthoracic spine is a point of controversy. The objective of this study was the biomechanical evaluation of a burst fracture at T-9 with an intact rib cage using different fixation constructs for stabilizing the spine. Methods A total of 8 human cadaveric spines (C7–L1) with intact rib cages were used in this study. The range of motion (ROM) between T-8 and T-10 was the outcome measure. A robotic spine testing system was programmed to apply pure moment loads (± 5 Nm) in lateral bending, flexion-extension, and axial rotation to whole thoracic specimens. Intersegmental rotations were measured using an optoelectronic system. Flexibility tests were conducted on intact specimens, then sequentially after surgically induced fracture at T-9, and after each of 4 fixation construct patterns. The 4 construct patterns were sequentially tested in a nondestructive protocol, as follows: 1) 3 above/2 below (3A/2B); 2) 1 above/1 below (1A/1B); 3) 1 above/1 below with vertebral body augmentation (1A/1B w/VA); and 4) vertebral body augmentation with no posterior instrumentation (VA). A repeated-measures ANOVA was used to compare the segmental motion between T-8 and T-10 vertebrae. Results Mean ROM increased by 86%, 151%, and 31% after fracture in lateral bending, flexion-extension, and axial rotation, respectively. In lateral bending, there was significant reduction compared with intact controls for all 3 instrumented constructs: 3A/2B (−92%, p = 0.0004), 1A/1B (−63%, p = 0.0132), and 1A/1B w/VA (−66%, p = 0.0150). In flexion-extension, only the 3A/2B pattern showed a significant reduction (−90%, p = 0.011). In axial rotation, motion was significantly reduced for the 3 instrumented constructs: 3A/2B (−66%, p = 0.0001), 1A/1B (−53%, p = 0.0001), and 1A/1B w/VA (−51%, p = 0.0002). Between the 4 construct patterns, the 3 instrumented constructs (3A/2B, 1A/1B, and 1A/1B w/VA) showed comparable stability in all 3 motion planes. Conclusions This study showed no significant difference in the stability of the 3 instrumented constructs tested when the rib cage is intact. Fractures that might appear more grossly unstable when tested in the disarticulated spine may be bolstered by the ribs. This may affect the extent of segmental spinal instrumentation needed to restore stability in some spine injuries. While these initial findings suggest that shorter constructs may adequately stabilize the spine in this fracture model, further study is needed before these results can be extrapolated to clinical application.

2008 ◽  
Vol 9 (3) ◽  
pp. 296-300 ◽  
Author(s):  
Michael A. Finn ◽  
Daniel R. Fassett ◽  
Todd D. Mccall ◽  
Randy Clark ◽  
Andrew T. Dailey ◽  
...  

Object Stabilization with rigid screw/rod fixation is the treatment of choice for craniocervical disorders requiring operative stabilization. The authors compare the relative immediate stiffness for occipital plate fixation in concordance with transarticular screw fixation (TASF), C-1 lateral mass and C-2 pars screw (C1L-C2P), and C-1 lateral mass and C-2 laminar screw (C1L-C2L) constructs, with and without a cross-link. Methods Ten intact human cadaveric spines (Oc–C4) were prepared and mounted in a 7-axis spine simulator. Each specimen was precycled and then tested in the intact state for flexion/extension, lateral bending, and axial rotation. Motion was tracked using the OptoTRAK 3D tracking system. The specimens were then destabilized and instrumented with an occipital plate and TASF. The spine was tested with and without the addition of a cross-link. The C1L-C2P and C1L-C2L constructs were similarly tested. Results All constructs demonstrated a significant increase in stiffness after instrumentation. The C1L-C2P construct was equivalent to the TASF in all moments. The C1L-C2L was significantly weaker than the C1L-C2P construct in all moments and significantly weaker than the TASF in lateral bending. The addition of a cross-link made no difference in the stiffness of any construct. Conclusions All constructs provide significant immediate stability in the destabilized occipitocervical junction. Although the C1L-C2P construct performed best overall, the TASF was similar, and either one can be recommended. Decreased stiffness of the C1L-C2L construct might affect the success of clinical fusion. This construct should be reserved for cases in which anatomy precludes the use of the other two.


2021 ◽  
pp. 1-9

OBJECTIVE Low fusion rates and cage subsidence are limitations of lumbar fixation with stand-alone interbody cages. Various approaches to interbody cage placement exist, yet the need for supplemental posterior fixation is not clear from clinical studies. Therefore, as prospective clinical studies are lacking, a comparison of segmental kinematics, cage properties, and load sharing on vertebral endplates is needed. This laboratory investigation evaluates the mechanical stability and biomechanical properties of various interbody fixation techniques by performing cadaveric and finite element (FE) modeling studies. METHODS An in vitro experiment using 7 fresh-frozen human cadavers was designed to test intact spines with 1) stand-alone lateral interbody cage constructs (lateral interbody fusion, LIF) and 2) LIF supplemented with posterior pedicle screw-rod fixation (360° constructs). FE and kinematic data were used to validate a ligamentous FE model of the lumbopelvic spine. The validated model was then used to evaluate the stability of stand-alone LIF, transforaminal lumbar interbody fusion (TLIF), and anterior lumbar interbody fusion (ALIF) cages with and without supplemental posterior fixation at the L4–5 level. The FE models of intact and instrumented cases were subjected to a 400-N compressive preload followed by an 8-Nm bending moment to simulate physiological flexion, extension, bending, and axial rotation. Segmental kinematics and load sharing at the inferior endplate were compared. RESULTS The FE kinematic predictions were consistent with cadaveric data. The range of motion (ROM) in LIF was significantly lower than intact spines for both stand-alone and 360° constructs. The calculated reduction in motion with respect to intact spines for stand-alone constructs ranged from 43% to 66% for TLIF, 67%–82% for LIF, and 69%–86% for ALIF in flexion, extension, lateral bending, and axial rotation. In flexion and extension, the maximum reduction in motion was 70% for ALIF versus 81% in LIF for stand-alone cases. When supplemented with posterior fixation, the corresponding reduction in ROM was 76%–87% for TLIF, 86%–91% for LIF, and 90%–92% for ALIF. The addition of posterior instrumentation resulted in a significant reduction in peak stress at the superior endplate of the inferior segment in all scenarios. CONCLUSIONS Stand-alone ALIF and LIF cages are most effective in providing stability in lateral bending and axial rotation and less so in flexion and extension. Supplemental posterior instrumentation improves stability for all interbody techniques. Comparative clinical data are needed to further define the indications for stand-alone cages in lumbar fusion surgery.


2021 ◽  
pp. 1-9

OBJECTIVE Excessive stress and motion at the L5–S1 level can lead to degenerative changes, especially in patients with posterior instrumentation suprajacent to L5. Attention has turned to utilization of L5–S1 anterior lumbar interbody fusion (ALIF) to stabilize the lumbosacral junction. However, questions remain regarding the effectiveness of stand-alone ALIF in the setting of prior posterior instrumented fusions terminating at L5. The purpose of this study was to assess the biomechanical stability of an L5–S1 ALIF with increasing lengths of posterior thoracolumbar constructs. METHODS Seven human cadaveric spines (T9–sacrum) were instrumented with pedicle screws from T10 to L5 and mounted to a 6 degrees-of-freedom robot. Posterior fusion construct lengths (T10–L5, T12–L5, L2–5, and L4–5) were instrumented to each specimen, and torque-fusion level relationships were determined for each construct in flexion-extension, axial rotation, and lateral bending. A stand-alone L5–S1 ALIF was then instrumented, and L5–S1 motion was measured as increasing pure moments (2 to 12 Nm) were applied. Motion reduction was calculated by comparing L5–S1 motion across the ALIF and non-ALIF states. RESULTS The average motion at L5–S1 in axial rotation, flexion-extension, and lateral bending was assessed for each fusion construct with and without ALIF. After adding ALIF to a posterior fusion, L5–S1 motion was significantly reduced relative to the non-ALIF state in all but one fused surgical condition (p < 0.05). Longer fusions with ALIF produced larger L5–S1 motions, and in some cases resulted in motions higher than native state motion. CONCLUSIONS Posterior fusion constructs up to L4–5 could be appropriately stabilized by a stand-alone L5–S1 ALIF when using a nominal threshold of 80% reduction in native motion as a potential positive indicator of fusion. The results of this study allow conclusions to be drawn from a biomechanical standpoint; however, the clinical implications of these data are not well defined. These findings, when taken in appropriate clinical context, can be used to better guide clinicians seeking to treat L5–S1 pathology in patients with prior posterior thoracolumbar constructs.


2010 ◽  
Vol 13 (2) ◽  
pp. 234-239 ◽  
Author(s):  
Frank S. Bishop ◽  
Mical M. Samuelson ◽  
Michael A. Finn ◽  
Kent N. Bachus ◽  
Darrel S. Brodke ◽  
...  

Object Thoracolumbar corpectomy is a procedure commonly required for the treatment of various pathologies involving the vertebral body. Although the biomechanical stability of anterior reconstruction with plating has been studied, the biomechanical contribution of posterior instrumentation to anterior constructs remains unknown. The purpose of this study was to evaluate biomechanical stability after anterior thoracolumbar corpectomy and reconstruction with varying posterior constructs by measuring bending stiffness for the axes of flexion/extension, lateral bending, and axial rotation. Methods Seven fresh human cadaveric thoracolumbar spine specimens were tested intact and after L-1 corpectomy and strut grafting with 4 different fixation techniques: anterior plating with bilateral, ipsilateral, contralateral, or no posterior pedicle screw fixation. Bending stiffness was measured under pure moments of ± 5 Nm in flexion/extension, lateral bending, and axial rotation, while maintaining an axial preload of 100 N with a follower load. Results for each configuration were normalized to the intact condition and were compared using ANOVA. Results Spinal constructs with anterior-posterior spinal reconstruction and bilateral posterior pedicle screws were significantly stiffer in flexion/extension than intact spines or spines with anterior plating alone. Anterior plating without pedicle screw fixation was no different from the intact spine in flexion/extension and lateral bending. All constructs had reduced stiffness in axial rotation compared with intact spines. Conclusions The addition of bilateral posterior instrumentation provided significantly greater stability at the thoracolumbar junction after total corpectomy than anterior plating and should be considered in cases in which anterior column reconstruction alone may be insufficient. In cases precluding bilateral posterior fixation, unilateral posterior instrumentation may provide some additional stability.


2019 ◽  
Vol 40 (2) ◽  
pp. 220-229
Author(s):  
Mu-Yi Liu ◽  
Tsung-Ting Tsai ◽  
Lih-Huei Chen ◽  
Wen-Huang Liang ◽  
Po-Liang Lai ◽  
...  

Abstract Purpose Lumbar posterior instrumentation for facet stabilization has become popular for the treatment of lumbar instability. The present study investigated and compared facet stabilization following lumbar posterior instrumentation with facet spacers and facet screws using porcine lumbar spines. Methods Eighteen L5–L6 lumbar motion units (LMUs) of the porcine spines were randomly divided into three groups (un-instrumented, facet-spacer and facet-screw). In the un-instrumented group (control), all ligamentous structures were preserved. In the facet-spacer group, two facet spacers were inserted into the joint spaces of the bilateral upper and lower facets. In the facet-screw group, two cannulated screws were used to transfix the bilateral upper and lower facets. With the use of a material testing machine, a gradually increasing moment of up to 6000 N-mm was generated in flexion, extension, lateral bending and torsion motions to compare facet stabilization among the groups. Results The facet-spacer group was significantly stiffer than the facet-screw group in extension (p = 0.013), whereas the facet-screw group was significantly stiffer than the facet-spacer group in axial rotation (p = 0.004). No statistically significant differences were observed between the two fixation techniques in flexion (p = 0.284) and lateral bending (p = 0.085). Conclusion Both facet-spacer and facet-screw fixation techniques significantly improve stability in a single LMU. Facet-spacer fixation provided better stabilization in extension, while facet-screw fixation provided better stabilization in axial rotation.


2013 ◽  
Vol 18 (4) ◽  
pp. 327-332 ◽  
Author(s):  
Andrew S. Little ◽  
Luis Perez-Orribo ◽  
Nestor G. Rodriguez-Martinez ◽  
Phillip M. Reyes ◽  
Anna G. U. S. Newcomb ◽  
...  

Object Endoscopic endonasal approaches to the craniovertebral junction (CVJ) and clivus are increasingly performed for ventral skull-base pathology, but the biomechanical implications of these approaches have not been studied. The aim of this study was to investigate the spinal biomechanics of the CVJ after an inferior-third clivectomy and anterior intradural exposure of the foramen magnum as would be performed in an endonasal endoscopic surgical strategy. Methods Seven upper-cervical human cadaveric specimens (occiput [Oc]–C2) underwent nondestructive biomechanical flexibility testing during flexion-extension, axial rotation, and lateral bending at Oc–C1 and C1–2. Each specimen was tested intact, after an inferior-third clivectomy, and after ligamentous complex dissection simulating a wide intradural exposure using an anterior approach. Angular range of motion (ROM), lax zone, and stiff zone were determined and compared with the intact state. Results Modest, but statistically significant, hypermobility was observed after inferior-third clivectomy and intradural exposure during flexion-extension and axial rotation at Oc–C1. Angular ROM increased incrementally between 6% and 12% in flexion-extension and axial rotation. These increases were primarily the result of changes in the lax zone. No significant changes were noted at C1–2. Conclusions Inferior-third clivectomy and an intradural exposure to the ventral CVJ and foramen magnum resulted in hypermobility at Oc–C1 during flexion-extension and axial rotation. Although the results were statistically significant, the modest degree of hypermobility observed compared with other well-characterized CVJ injuries suggests that occipitocervical stabilization may be unnecessary for most patients.


2020 ◽  
Author(s):  
xiaoyong zheng ◽  
qingwen yu ◽  
zhi zhang

Abstract Background: For fresh thoracolumbar burst fracture, a new method which can not only promote the fracture healing, but also retain the movement segment, and restore the spinal movement function to the maximum extent is needed. The purpose of this study is to determine the performance of stabilization of a semi-rigid stabilization system combined with transpedicular intracorporeal bone grafting for thoracolumbar burst fractures.Methods Six thoracolumbar cadaver spines were used for testing. A controlled L2 burst fracture was created. The L1-3 motions were determined.Results In extension, flexion and lateral bending, the semi-rigid fixator stabilized the segment to a range of motion(ROM) and neutral zone(NZ) below the magnitude of the intact spine, but showed increased ROM and NZ of axial rotation (P < 0.05) compared with the intact spine.Conclusions Restoration of stability with the semi-rigid dynamic system combined with transpedicular intracorporeal bone grafting is possible in flexion, extension, right and left lateral bending for thoracolumbar burst fracture but for axial rotation.


Author(s):  
Luis Fernando Nicolini ◽  
Philipp Kobbe ◽  
Jana Seggewiß ◽  
Johannes Greven ◽  
Marx Ribeiro ◽  
...  

Abstract Purpose There is a paucity of studies on new vertebral body tethering (VBT) surgical constructs especially regarding their potentially motion-preserving ability. This study analyses their effects on the ROM of the spine. Methods Human spines (T10-L3) were tested under pure moment in four different conditions: (1) native, (2) instrumented with one tether continuously connected in all vertebrae from T10 to L3, (3) additional instrumented with a second tether continuously connected in all vertebrae from T11 to L3, and (4) instrumented with one tether and one titanium rod (hybrid) attached to T12, L1 and L2. The instrumentation was inserted in the left lateral side. The intersegmental ROM was evaluated using a magnetic tracking system, and the medians were analysed. Please check and confirm the author names and initials are correct. Also, kindly confirm the details in the metadata are correct. The mentioned information is correct Results Compared to the native spine, the instrumented spine presented a reduction of less than 13% in global ROM considering flexion–extension and axial rotation. For left lateral bending, the median global ROM of the native spine (100%) significantly reduced to 74.6%, 66.4%, and 68.1% after testing one tether, two tethers and the hybrid construction, respectively. In these cases, the L1-L2 ROM was reduced to 68.3%, 58.5%, and 38.3%, respectively. In right lateral bending, the normalized global ROM of the spine with one tether, two tethers and the hybrid construction was 58.9%, 54.0%, and 56.6%, respectively. Considering the same order, the normalized L1-L2 ROM was 64.3%, 49.9%, and 35.3%, respectively. Conclusion The investigated VBT techniques preserved global ROM of the spine in flexion–extension and axial rotation while reduced the ROM in lateral bending.


Neurosurgery ◽  
2013 ◽  
Vol 72 (6) ◽  
pp. 1021-1030 ◽  
Author(s):  
Luis Perez-Orribo ◽  
Andrew S. Little ◽  
Richard D. Lefevre ◽  
Phillip R. Reyes ◽  
Anna G.U.S. Newcomb ◽  
...  

Abstract BACKGROUND: Endoscopic endonasal approaches to the craniovertebral junction and clivus, which are increasingly performed for ventral skull base pathology, may require disruption of the occipitocondylar joint. OBJECTIVE: To study the biomechanical implications at the craniovertebral junction of progressive unilateral condylectomy as would be performed through an endonasal exposure. METHODS: Seven upper cervical human cadaveric specimens (C0-C2) underwent nondestructive biomechanical flexibility testing during flexion-extension, axial rotation, and lateral bending at C0-C1 and C1-C2. Each specimen was tested intact, after an inferior one-third clivectomy, and after stepwise unilateral condylectomy with an anterior approach. Angular range of motion (ROM), lax zone, and stiff zone were determined and compared with the intact state. RESULTS: At C0-C1, mobility during flexion-extension and axial rotation increased significantly with progressive condylectomy. ROM increased from 14.3 ± 2.7° to 20.4 ± 5.2° during flexion and from 6.7 ± 3.5° to 10.8 ± 3.0° during right axial rotation after 75% condyle resection (P &lt; .01). At C1-C2, condylectomy had less effect, with ROM increasing from 10.7 ± 2.0° to 11.7 ± 2.0° during flexion, 36.9 ± 4.8° to 37.1 ± 5.1° during right axial rotation, and 4.3 ± 1.9° to 4.8 ± 3.3° during right lateral bending (P = NS). Because of marked instability, the 100% condylectomy condition was untestable. Changes in ROM were a result of changes more in the lax zone than in the stiff zone. CONCLUSION: Lower-third clivectomy and unilateral anterior condylectomy as would be performed in an endonasal approach cause progressive hypermobility at the craniovertebral junction. On the basis of biomechanical criteria, craniocervical fusion is indicated for patients who undergo &gt; 75% anterior condylectomy.


2008 ◽  
Vol 8 (2) ◽  
pp. 143-152 ◽  
Author(s):  
Nicholas C. Bambakidis ◽  
Iman Feiz-Erfan ◽  
Eric M. Horn ◽  
L. Fernando Gonzalez ◽  
Seungwon Baek ◽  
...  

Object The stability provided by 3 occipitoatlantal fixation techniques (occiput [Oc]–C1 transarticular screws, occipital keel screws rigidly interconnected with C-1 lateral mass screws, and suboccipital/sublaminar wired contoured rod) were compared. Methods Seven human cadaveric specimens received transarticular screws and 7 received occipital keel–C1 lateral mass screws. All specimens later underwent contoured rod fixation. All conditions were studied with and without placement of a structural graft wired between the skull base and C-1 lamina. Specimens were loaded quasistatically using pure moments to induce flexion, extension, lateral bending, and axial rotation while recording segmental motion optoelectronically. Flexibility was measured immediately postoperatively and after 10,000 cycles of fatigue. Results Application of Oc–C1 transarticular screws, with a wired graft, reduced the mean range of motion (ROM) to 3% of normal. Occipital keel–C1 lateral mass screws (also with graft) offered less stability than transarticular screws during extension and lateral bending (p < 0.02), reducing ROM to 17% of normal. The wired contoured rod reduced motion to 31% of normal, providing significantly less stability than either screw fixation technique. Fatigue increased motion in constructs fitted with transarticular screws, keel screws/lateral mass screw constructs, and contoured wired rods, by means of 19, 5, and 26%, respectively. In all constructs, adding a structural graft significantly improved stability, but the extent depended on the loading direction. Conclusions Assuming the presence of mild C1–2 instability, Oc–C1 transarticular screws and occipital keel–C1 lateral mass screws are approximately equivalent in performance for occipitoatlantal stabilization in promoting fusion. A posteriorly wired contoured rod is less likely to provide a good fusion environment because of less stabilizing potential and a greater likelihood of loosening with fatigue.