scholarly journals Biomechanical Comparison of Lumbar Motion Unit Stability Following Posterior Instrumentation with Facet Spacers and Facet Screws

2019 ◽  
Vol 40 (2) ◽  
pp. 220-229
Author(s):  
Mu-Yi Liu ◽  
Tsung-Ting Tsai ◽  
Lih-Huei Chen ◽  
Wen-Huang Liang ◽  
Po-Liang Lai ◽  
...  

Abstract Purpose Lumbar posterior instrumentation for facet stabilization has become popular for the treatment of lumbar instability. The present study investigated and compared facet stabilization following lumbar posterior instrumentation with facet spacers and facet screws using porcine lumbar spines. Methods Eighteen L5–L6 lumbar motion units (LMUs) of the porcine spines were randomly divided into three groups (un-instrumented, facet-spacer and facet-screw). In the un-instrumented group (control), all ligamentous structures were preserved. In the facet-spacer group, two facet spacers were inserted into the joint spaces of the bilateral upper and lower facets. In the facet-screw group, two cannulated screws were used to transfix the bilateral upper and lower facets. With the use of a material testing machine, a gradually increasing moment of up to 6000 N-mm was generated in flexion, extension, lateral bending and torsion motions to compare facet stabilization among the groups. Results The facet-spacer group was significantly stiffer than the facet-screw group in extension (p = 0.013), whereas the facet-screw group was significantly stiffer than the facet-spacer group in axial rotation (p = 0.004). No statistically significant differences were observed between the two fixation techniques in flexion (p = 0.284) and lateral bending (p = 0.085). Conclusion Both facet-spacer and facet-screw fixation techniques significantly improve stability in a single LMU. Facet-spacer fixation provided better stabilization in extension, while facet-screw fixation provided better stabilization in axial rotation.

2010 ◽  
Vol 13 (2) ◽  
pp. 234-239 ◽  
Author(s):  
Frank S. Bishop ◽  
Mical M. Samuelson ◽  
Michael A. Finn ◽  
Kent N. Bachus ◽  
Darrel S. Brodke ◽  
...  

Object Thoracolumbar corpectomy is a procedure commonly required for the treatment of various pathologies involving the vertebral body. Although the biomechanical stability of anterior reconstruction with plating has been studied, the biomechanical contribution of posterior instrumentation to anterior constructs remains unknown. The purpose of this study was to evaluate biomechanical stability after anterior thoracolumbar corpectomy and reconstruction with varying posterior constructs by measuring bending stiffness for the axes of flexion/extension, lateral bending, and axial rotation. Methods Seven fresh human cadaveric thoracolumbar spine specimens were tested intact and after L-1 corpectomy and strut grafting with 4 different fixation techniques: anterior plating with bilateral, ipsilateral, contralateral, or no posterior pedicle screw fixation. Bending stiffness was measured under pure moments of ± 5 Nm in flexion/extension, lateral bending, and axial rotation, while maintaining an axial preload of 100 N with a follower load. Results for each configuration were normalized to the intact condition and were compared using ANOVA. Results Spinal constructs with anterior-posterior spinal reconstruction and bilateral posterior pedicle screws were significantly stiffer in flexion/extension than intact spines or spines with anterior plating alone. Anterior plating without pedicle screw fixation was no different from the intact spine in flexion/extension and lateral bending. All constructs had reduced stiffness in axial rotation compared with intact spines. Conclusions The addition of bilateral posterior instrumentation provided significantly greater stability at the thoracolumbar junction after total corpectomy than anterior plating and should be considered in cases in which anterior column reconstruction alone may be insufficient. In cases precluding bilateral posterior fixation, unilateral posterior instrumentation may provide some additional stability.


Neurosurgery ◽  
2006 ◽  
Vol 58 (3) ◽  
pp. 516-521 ◽  
Author(s):  
Samir B. Lapsiwala ◽  
Paul A. Anderson ◽  
Ashish Oza ◽  
Daniel K. Resnick

Abstract OBJECTIVE: We performed a biomechanical comparison of several C1 to C2 fixation techniques including crossed laminar (intralaminar) screw fixation, anterior C1 to C2 transarticular screw fixation, C1 to 2 pedicle screw fixation, and posterior C1 to C2 transarticular screw fixation. METHODS: Eight cadaveric cervical spines were tested intact and after dens fracture. Four different C1 to C2 screw fixation techniques were tested. Posterior transarticular and pedicle screw constructs were tested twice, once with supplemental sublaminar cables and once without cables. The specimens were tested in three modes of loading: flexion-extension, lateral bending, and axial rotation. All tests were performed in load and torque control. Pure bending moments of 2 nm were applied in flexion-extension and lateral bending, whereas a 1 nm moment was applied in axial rotation. Linear displacements were recorded from extensometers rigidly affixed to the C1 and C2 vertebrae. Linear displacements were reduced to angular displacements using trigonometry. RESULTS: Adding cable fixation results in a stiffer construct for posterior transarticular screws. The addition of cables did not affect the stiffness of C1 to C2 pedicle screw constructs. There were no significant differences in stiffness between anterior and posterior transarticular screw techniques, unless cable fixation was added to the posterior construct. All three posterior screw constructs with supplemental cable fixation provide equal stiffness with regard to flexion-extension and axial rotation. C1 lateral mass-C2 intralaminar screw fixation restored resistance to lateral bending but not to the same degree as the other screw fixation techniques. CONCLUSION: All four screw fixation techniques limit motion at the C1 to 2 articulation. The addition of cable fixation improves resistance to flexion and extension for posterior transarticular screw fixation.


2008 ◽  
Vol 8 (2) ◽  
pp. 143-152 ◽  
Author(s):  
Nicholas C. Bambakidis ◽  
Iman Feiz-Erfan ◽  
Eric M. Horn ◽  
L. Fernando Gonzalez ◽  
Seungwon Baek ◽  
...  

Object The stability provided by 3 occipitoatlantal fixation techniques (occiput [Oc]–C1 transarticular screws, occipital keel screws rigidly interconnected with C-1 lateral mass screws, and suboccipital/sublaminar wired contoured rod) were compared. Methods Seven human cadaveric specimens received transarticular screws and 7 received occipital keel–C1 lateral mass screws. All specimens later underwent contoured rod fixation. All conditions were studied with and without placement of a structural graft wired between the skull base and C-1 lamina. Specimens were loaded quasistatically using pure moments to induce flexion, extension, lateral bending, and axial rotation while recording segmental motion optoelectronically. Flexibility was measured immediately postoperatively and after 10,000 cycles of fatigue. Results Application of Oc–C1 transarticular screws, with a wired graft, reduced the mean range of motion (ROM) to 3% of normal. Occipital keel–C1 lateral mass screws (also with graft) offered less stability than transarticular screws during extension and lateral bending (p < 0.02), reducing ROM to 17% of normal. The wired contoured rod reduced motion to 31% of normal, providing significantly less stability than either screw fixation technique. Fatigue increased motion in constructs fitted with transarticular screws, keel screws/lateral mass screw constructs, and contoured wired rods, by means of 19, 5, and 26%, respectively. In all constructs, adding a structural graft significantly improved stability, but the extent depended on the loading direction. Conclusions Assuming the presence of mild C1–2 instability, Oc–C1 transarticular screws and occipital keel–C1 lateral mass screws are approximately equivalent in performance for occipitoatlantal stabilization in promoting fusion. A posteriorly wired contoured rod is less likely to provide a good fusion environment because of less stabilizing potential and a greater likelihood of loosening with fatigue.


2011 ◽  
Vol 14 (5) ◽  
pp. 639-646 ◽  
Author(s):  
Jon Park ◽  
Justin K. Scheer ◽  
T. Jesse Lim ◽  
Vedat Deviren ◽  
Christopher P. Ames

Object The Goel technique, in which C1–2 intraarticular spacers are used, may be performed to restore stability to a disrupted atlantoaxial complex in conjunction with the Harms technique of placing polyaxial screws and bilateral rods. However, it has yet to be determined biomechanically whether the addition of the C1–2 joint spacers increases the multiaxial rigidity of the fixation construct. The goal of this study was to quantify changes in multiaxial rigidity of the combined Goel-Harms technique with the addition of C1–2 intraarticular spacers. Methods Seven cadaveric cervical spines (occiput–C2) were submitted to nondestructive flexion-extension, lateral bending, and axial rotation tests in a material testing machine spine tester. The authors applied 1.5 Nm at a rate of 0.1 Nm/second and held it constant for 10 seconds. The specimens were loaded 3 times, and data were collected on the third cycle. Testing of the specimens was performed for the following groups: 1) intact (I); 2) with the addition of C-1 lateral mass/C-2 pedicle screws and rod system (I+SR); 3) with C1–2 joint capsule incision, decortication (2 mm on top and bottom of each joint [that is, the C-1 and C-2 surface) and addition of bilateral C1–2 intraarticular spacers at C1–2 junction to the screws and rods (I+SR+C); 4) after removal of the posterior rods and only the bilateral spacers in place (I+C); 5) after removal of spacers and further destabilization with simulated odontoidectomy for a completely destabilized case (D); 6) with addition of posterior rods to the destabilized case (D+SR); and 7) with addition of bilateral C1–2 intraarticular spacers at C1–2 junction to the destabilized case (D+SR+C). The motion of C-1 was measured by a 3D motion tracking system and the motion of C-2 was measured by the rotational sensor of the testing system. The range of motion (ROM) and neutral zone (NZ) across C-1 and C-2 were evaluated. Results For the intact spine test groups, the addition of screws/rods (I+SR) and screws/rods/cages (I+SR+C) significantly reduced ROM and NZ compared with the intact spine (I) for flexion-extension and axial rotation (p < 0.05) but not lateral bending (p > 0.05). The 2 groups were not significantly different from each other in any bending mode for ROM and NZ, but in the destabilized condition the addition of screws/rods (D+SR) and screws/rods/cages (D+SR+C) significantly reduced ROM and NZ compared with the destabilized spine (D) in all bending modes (p < 0.05). Furthermore, the addition of the C1–2 intraarticular spacers (D+SR+C) significantly reduced ROM (flexion-extension and axial rotation) and NZ (lateral bending) compared with the screws and rods alone (D+SR). Conclusions Study result indicated that both the Goel and Harms techniques alone and with the addition of the C1–2 intraarticular spacers to the Goel-Harms technique are advantageous for stabilizing the atlantoaxial segment. The Goel technique combined with placement of a screw/rod construct appears to result in additional construct rigidity beyond the screw/rod technique and appears to be more useful in very unstable cases.


2014 ◽  
Vol 21 (3) ◽  
pp. 481-488 ◽  
Author(s):  
Tiffany G. Perry ◽  
Prasath Mageswaran ◽  
Robb W. Colbrunn ◽  
Tara F. Bonner ◽  
Todd Francis ◽  
...  

Object Classic biomechanical models have used thoracic spines disarticulated from the rib cage, but the biomechanical influence of the rib cage on fracture biomechanics has not been investigated. The well-accepted construct for stabilizing midthoracic fractures is posterior instrumentation 3 levels above and 2 levels below the injury. Short-segment fixation failure in thoracolumbar burst fractures has led to kyphosis and implant failure when anterior column support is lacking. Whether shorter constructs are viable in the midthoracic spine is a point of controversy. The objective of this study was the biomechanical evaluation of a burst fracture at T-9 with an intact rib cage using different fixation constructs for stabilizing the spine. Methods A total of 8 human cadaveric spines (C7–L1) with intact rib cages were used in this study. The range of motion (ROM) between T-8 and T-10 was the outcome measure. A robotic spine testing system was programmed to apply pure moment loads (± 5 Nm) in lateral bending, flexion-extension, and axial rotation to whole thoracic specimens. Intersegmental rotations were measured using an optoelectronic system. Flexibility tests were conducted on intact specimens, then sequentially after surgically induced fracture at T-9, and after each of 4 fixation construct patterns. The 4 construct patterns were sequentially tested in a nondestructive protocol, as follows: 1) 3 above/2 below (3A/2B); 2) 1 above/1 below (1A/1B); 3) 1 above/1 below with vertebral body augmentation (1A/1B w/VA); and 4) vertebral body augmentation with no posterior instrumentation (VA). A repeated-measures ANOVA was used to compare the segmental motion between T-8 and T-10 vertebrae. Results Mean ROM increased by 86%, 151%, and 31% after fracture in lateral bending, flexion-extension, and axial rotation, respectively. In lateral bending, there was significant reduction compared with intact controls for all 3 instrumented constructs: 3A/2B (−92%, p = 0.0004), 1A/1B (−63%, p = 0.0132), and 1A/1B w/VA (−66%, p = 0.0150). In flexion-extension, only the 3A/2B pattern showed a significant reduction (−90%, p = 0.011). In axial rotation, motion was significantly reduced for the 3 instrumented constructs: 3A/2B (−66%, p = 0.0001), 1A/1B (−53%, p = 0.0001), and 1A/1B w/VA (−51%, p = 0.0002). Between the 4 construct patterns, the 3 instrumented constructs (3A/2B, 1A/1B, and 1A/1B w/VA) showed comparable stability in all 3 motion planes. Conclusions This study showed no significant difference in the stability of the 3 instrumented constructs tested when the rib cage is intact. Fractures that might appear more grossly unstable when tested in the disarticulated spine may be bolstered by the ribs. This may affect the extent of segmental spinal instrumentation needed to restore stability in some spine injuries. While these initial findings suggest that shorter constructs may adequately stabilize the spine in this fracture model, further study is needed before these results can be extrapolated to clinical application.


2014 ◽  
Vol 20 (5) ◽  
pp. 485-491 ◽  
Author(s):  
Vincent C. Traynelis ◽  
Jonathan Sherman ◽  
Eric Nottmeier ◽  
Vaneet Singh ◽  
Kirk McGilvray ◽  
...  

Object The clinical success rates of anterior cervical discectomy and fusion (ACDF) procedures are substantially reduced as more cervical levels are included in the fusion procedure. One method that has been proposed as an adjunctive technique for multilevel ACDF is the placement of screws across the facet joints (“transfacet screws”). However, the biomechanical stability imparted by transfacet screw placement (either unilaterally or bilaterally) has not been reported. Therefore, the purpose of this study was to determine the acute stability conferred by implementation of unilateral and bilateral transfacet screws to an ACDF construct. Methods Eight C2–T1 fresh-frozen human cadaveric spines (3 female and 5 male; mean age 50 years) were tested. Three different instrumentation variants were performed on cadaveric cervical spines across C4–7: 1) ACDF with an intervertebral spacer and standard plate/screw instrumentation; 2) ACDF with an intervertebral spacer and standard plate/screw instrumentation with unilateral facet screw placement; and 3) ACDF with an intervertebral spacer and standard plate/screw instrumentation with bilateral facet screw placement. Kinetic ranges of motion in flexion-extension, lateral bending, and axial rotation at 1.5 Nm were captured after each of these procedures and were statistically analyzed for significance. Results All 3 fixation scenarios produced statistically significant reductions (p < 0.05) in all 3 bending planes compared with the intact condition. The addition of a unilateral facet screw to the ACDF construct produced significant reductions at the C4–5 and C6–7 levels in lateral bending and axial rotation but not in flexion-extension motion. Bilateral facet screw fixation did not produce any statistically significant decreases in flexion-extension motion compared with unilateral facet screw fixation. However, in lateral bending, significant reductions at the C4–5 and C5–6 levels were observed with the addition of a second facet screw. The untreated, adjacent levels (C2–3, C3–4, and C7–1) did not demonstrate significant differences in range of motion. Conclusions The data demonstrated that adjunctive unilateral facet screw fixation to an ACDF construct provides significant gains in stability and should be considered a potential option for increasing the likelihood for obtaining a successful arthrodesis for multilevel ACDF procedures.


2021 ◽  
pp. 1-9

OBJECTIVE Low fusion rates and cage subsidence are limitations of lumbar fixation with stand-alone interbody cages. Various approaches to interbody cage placement exist, yet the need for supplemental posterior fixation is not clear from clinical studies. Therefore, as prospective clinical studies are lacking, a comparison of segmental kinematics, cage properties, and load sharing on vertebral endplates is needed. This laboratory investigation evaluates the mechanical stability and biomechanical properties of various interbody fixation techniques by performing cadaveric and finite element (FE) modeling studies. METHODS An in vitro experiment using 7 fresh-frozen human cadavers was designed to test intact spines with 1) stand-alone lateral interbody cage constructs (lateral interbody fusion, LIF) and 2) LIF supplemented with posterior pedicle screw-rod fixation (360° constructs). FE and kinematic data were used to validate a ligamentous FE model of the lumbopelvic spine. The validated model was then used to evaluate the stability of stand-alone LIF, transforaminal lumbar interbody fusion (TLIF), and anterior lumbar interbody fusion (ALIF) cages with and without supplemental posterior fixation at the L4–5 level. The FE models of intact and instrumented cases were subjected to a 400-N compressive preload followed by an 8-Nm bending moment to simulate physiological flexion, extension, bending, and axial rotation. Segmental kinematics and load sharing at the inferior endplate were compared. RESULTS The FE kinematic predictions were consistent with cadaveric data. The range of motion (ROM) in LIF was significantly lower than intact spines for both stand-alone and 360° constructs. The calculated reduction in motion with respect to intact spines for stand-alone constructs ranged from 43% to 66% for TLIF, 67%–82% for LIF, and 69%–86% for ALIF in flexion, extension, lateral bending, and axial rotation. In flexion and extension, the maximum reduction in motion was 70% for ALIF versus 81% in LIF for stand-alone cases. When supplemented with posterior fixation, the corresponding reduction in ROM was 76%–87% for TLIF, 86%–91% for LIF, and 90%–92% for ALIF. The addition of posterior instrumentation resulted in a significant reduction in peak stress at the superior endplate of the inferior segment in all scenarios. CONCLUSIONS Stand-alone ALIF and LIF cages are most effective in providing stability in lateral bending and axial rotation and less so in flexion and extension. Supplemental posterior instrumentation improves stability for all interbody techniques. Comparative clinical data are needed to further define the indications for stand-alone cages in lumbar fusion surgery.


2019 ◽  
Vol 19 (2) ◽  
pp. 157-164 ◽  
Author(s):  
Ilyas M Eli ◽  
Michael Karsy ◽  
Darrel S Brodke ◽  
Kent N Bachus ◽  
William T Couldwell ◽  
...  

Abstract BACKGROUND Occipitocervical instability may result from transcondylar resection of the occipital condyle. Initially, patients may be able to maintain a neutral alignment but severe occipitoatlantal subluxation may subsequently occur, with cranial settling, spinal cord kinking, and neurological injury. OBJECTIVE To evaluate the ability of posterior fixation constructs to prevent progression to severe deformity after radical unilateral condylectomy. METHODS Eight human cadaveric specimens (Oc-C2) underwent biomechanical testing to compare stiffness under physiological loads (1.5 N m). A complete unilateral condylectomy was performed to destabilize one Oc-C1 joint, and the contralateral joint was left intact. Unilateral Oc-C1 or Oc-C2 constructs on the resected side and bilateral Oc-C1 or Oc-C2 constructs were tested. RESULTS The bilateral Oc-C2 construct provided the greatest stiffness, but the difference was only statistically significant in certain planes of motion. The unilateral constructs had similar stiffness in lateral bending, but the unilateral Oc-C1 construct was less stiff in axial rotation and flexion-extension than the unilateral Oc-C2 construct. The bilateral Oc-C2 construct was stiffer than the unilateral Oc-C2 construct in axial rotation and lateral bending, but there was no difference between these constructs in flexion-extension. CONCLUSION Patients who undergo a complete unilateral condylectomy require close surveillance for occipitocervical instability. A bilateral Oc-C2 construct provides suitable biomechanical strength, which is superior to other constructs. A unilateral construct decreases abnormal motion but lacks the stiffness of a bilateral construct. However, given that most patients undergo a partial condylectomy and only a small proportion of patients develop instability, there may be scenarios in which a unilateral construct may be appropriate, such as for temporary internal stabilization.


2017 ◽  
Vol 30 (06) ◽  
pp. 430-437 ◽  
Author(s):  
Nadja Bösch ◽  
Martin Hofstetter ◽  
Alexander Bürki ◽  
Beatriz Vidondo ◽  
Fenella Davies ◽  
...  

Abstract Objective To study the biomechanical effect of facetectomy in 10 large breed dogs (>24 kg body weight) on the fourth canine cervical functional spinal unit. Methods Canine cervical spines were freed from all muscles. Spines were mounted on a six-degrees-of-freedom spine testing machine for three-dimensional motion analysis. Data were recorded with an optoelectronic motion analysis system. The range of motion wasdetermined inall threeprimary motionsaswellasrange of motion of coupled motions on the intact specimen, after unilateral and after bilateral facetectomy. Repeated-measures analysis of variance models were used to assess the changes of the biomechanical properties in the three treatment groups considered. Results Facetectomy increased range of motion of primary motions in all directions. Axial rotation was significantly influenced by facetectomy. Coupled motion was not influenced by facetectomy except for lateral bending with coupled motion axial rotation. The coupling factor (coupled motion/primary motion) decreased after facetectomy. Symmetry of motion was influenced by facetectomy in flexion–extension and axial rotation, but not in lateral bending. Clinical Significance Facet joints play a significant role in the stability of the cervical spine and act to maintain spatial integrity. Therefore, cervical spinal treatments requiring a facetectomy should be carefully planned and if an excessive increase in range of motion is expected, complications should be anticipated and reduced via spinal stabilization.


2021 ◽  
pp. 1-9

OBJECTIVE Excessive stress and motion at the L5–S1 level can lead to degenerative changes, especially in patients with posterior instrumentation suprajacent to L5. Attention has turned to utilization of L5–S1 anterior lumbar interbody fusion (ALIF) to stabilize the lumbosacral junction. However, questions remain regarding the effectiveness of stand-alone ALIF in the setting of prior posterior instrumented fusions terminating at L5. The purpose of this study was to assess the biomechanical stability of an L5–S1 ALIF with increasing lengths of posterior thoracolumbar constructs. METHODS Seven human cadaveric spines (T9–sacrum) were instrumented with pedicle screws from T10 to L5 and mounted to a 6 degrees-of-freedom robot. Posterior fusion construct lengths (T10–L5, T12–L5, L2–5, and L4–5) were instrumented to each specimen, and torque-fusion level relationships were determined for each construct in flexion-extension, axial rotation, and lateral bending. A stand-alone L5–S1 ALIF was then instrumented, and L5–S1 motion was measured as increasing pure moments (2 to 12 Nm) were applied. Motion reduction was calculated by comparing L5–S1 motion across the ALIF and non-ALIF states. RESULTS The average motion at L5–S1 in axial rotation, flexion-extension, and lateral bending was assessed for each fusion construct with and without ALIF. After adding ALIF to a posterior fusion, L5–S1 motion was significantly reduced relative to the non-ALIF state in all but one fused surgical condition (p < 0.05). Longer fusions with ALIF produced larger L5–S1 motions, and in some cases resulted in motions higher than native state motion. CONCLUSIONS Posterior fusion constructs up to L4–5 could be appropriately stabilized by a stand-alone L5–S1 ALIF when using a nominal threshold of 80% reduction in native motion as a potential positive indicator of fusion. The results of this study allow conclusions to be drawn from a biomechanical standpoint; however, the clinical implications of these data are not well defined. These findings, when taken in appropriate clinical context, can be used to better guide clinicians seeking to treat L5–S1 pathology in patients with prior posterior thoracolumbar constructs.