Cerebral hemodynamics and metabolism in patients with cerebral arteriovenous malformations: an evaluation using positron emission tomography scanning

2002 ◽  
Vol 97 (6) ◽  
pp. 1314-1321 ◽  
Author(s):  
Toru Iwama ◽  
Kohei Hayashida ◽  
Jun C. Takahashi ◽  
Izumi Nagata ◽  
Nobuo Hashimoto

Object. The purpose of this study was to evaluate cerebral hemodynamic and metabolic features in patients with arteriovenous malformations (AVMs) by using positron emission tomography (PET) scanning. Methods. Twenty-four patients with supratentorial cerebral AVMs participated in PET studies in which 15O inhalation steady-state methods were used. The authors recorded the values of regional cerebral blood flow (rCBF), regional cerebral blood volume (rCBV), the regional oxygen extraction fraction (rOEF), and the regional cerebral metabolic rate of O2 (rCMRO2) at three designated regions of interest (ROIs) in each patient. These ROIs included perilesional (ROI-p), ipsilateral remote (ROI-i), and contralateral symmetrical (ROI-c) brain regions. To identify the factors that exert a direct effect on the hemodynamics of brains affected by AVM, we also separated the lesions according to their size and flow type shown on angiograms, and grouped the patients according to the presence or absence of progressive neurological deficits. We then compared the PET parameters at different ROIs in individual patients and evaluated the mean values obtained for all 24 patients according to AVM flow type and size, and the presence or absence of progressive neurological deficits. Conclusions. Overall, mean rCBV and rOEF values were significantly higher in ROI-p than in ROI-c (p = 0.00046 and p = 0.015, respectively). No significant differences were seen between the ROI-i and ROI-c with respect to rCBF, rCBV, and rOEF. Mean rCMRO2 values were similar in the three ROIs; however, the mean rCBF was significantly lower in the ROI-p than in the ROI-c in patients with high-flow AVMs (p = 0.019), large AVMs (p = 0.017), and progressive neurological deficits (p = 0.021). Furthermore, the mean rOEF values were significantly higher in the ROI-p than in the ROI-c in patients with high-flow AVMs (p = 0.005), large AVMs (p = 0.019), and progressive neurological deficits (p = 0.017). The PET studies revealed hemodynamic impairment characterized by decreased rCBF and increased rOEF and rCBV values in the ROI-p of patients with large, high-flow AVMs regardless of whether they exhibited progressive neurological deficits.

1994 ◽  
Vol 81 (6) ◽  
pp. 843-850 ◽  
Author(s):  
Kiyonobu Ikezaki ◽  
Toshio Matsushima ◽  
Yasuo Kuwabara ◽  
Satoshi O. Suzuki ◽  
Tomojiro Nomura ◽  
...  

✓ Thirteen children with moyamoya disease who had no apparent cerebral infarction or hemorrhage were examined pre- and postoperatively by means of positron emission tomography (PET) to investigate the underlying cerebral circulation and metabolism and the effect of bypass surgery. The preoperative regional cerebral blood flow (rCBF) and mean transit time were significantly decreased and increased, respectively, in the cerebral cortex of these patients compared to control values. The regional cerebral blood volume (rCBV) and the regional oxygen extraction fraction (rOEF) had significantly increased to compensate for the reduced rCBF and perfusion pressure and also to maintain the regional cerebral metabolic rate of oxygen (rCMRO2). In the basal ganglia, rCBV elevation was more prominent than that in the cerebral cortex, although changes in rCBF, rOEF, and rCMRO2 were relatively minor. Postoperative improvements were observed predominantly near the cortex where bypass surgery had been performed and in the basal ganglia. Direct and combined indirect bypass procedures improved cerebral circulation more effectively than single indirect bypass surgery. Although the angiographic findings were not always compatible with the clinical results, the postoperative improvements on PET scans correlated with the disappearance of transient ischemic attacks. In addition to the clinical courses and angiographic findings, PET analysis was indispensable in evaluating the cerebral circulation and metabolism in childhood moyamoya disease.


2002 ◽  
Vol 97 ◽  
pp. 542-550 ◽  
Author(s):  
Marc Levivier ◽  
David Wikler ◽  
Nicolas Massager ◽  
Philippe David ◽  
Daniel Devriendt ◽  
...  

Object. The authors review their experience with the clinical development and routine use of positron emission tomography (PET) during stereotactic procedures, including the use of PET-guided gamma knife radiosurgery (GKS). Methods. Techniques have been developed for the routine use of stereotactic PET, and accumulated experience using PET-guided stereotactic procedures over the past 10 years includes more than 150 stereotactic biopsies, 43 neuronavigation procedures, and 34 cases treated with GKS. Positron emission tomography—guided GKS was performed in 24 patients with primary brain tumors (four pilocytic astrocytomas, five low-grade astrocytomas or oligodendrogliomas, seven anaplastic astrocytomas or ependymomas, five glioblastomas, and three neurocytomas), five patients with metastases (single or multiple lesions), and five patients with pituitary adenomas. Conclusions. Data obtained with PET scanning can be integrated with GKS treatment planning, enabling access to metabolic information with high spatial accuracy. Positron emission tomography data can be successfully combined with magnetic resonance imaging data to provide specific information for defining the target volume for the radiosurgical treatment in patients with recurrent brain tumors, such as glioma, metastasis, and pituitary adenoma. This approach is particularly useful for optimizing target selection for infiltrating or ill-defined brain lesions. The use of PET scanning contributed data in 31 cases (93%) and information that was specifically utilized to adapt the target volume in 25 cases (74%). It would seem that the integration of PET data into GKS treatment planning may represent an important step toward further developments in radiosurgery: this approach provides additional information that may open new perspectives for the optimization of the treatment of brain tumors.


2000 ◽  
Vol 92 (6) ◽  
pp. 1009-1015 ◽  
Author(s):  
Seiji Yamamoto ◽  
Weiyu Teng ◽  
Shigeru Nishizawa ◽  
Takeharu Kakiuchi ◽  
Hideo Tsukada

Object. The hydroxyl radical scavenger (±)-N,N′-propylenedinicotinamide (AVS) has been shown to ameliorate the occurrence of vasospasm following experimental subarachnoid hemorrhage (SAH) and to reduce the incidence of delayed ischemic neurological deficits (DINDs) in patients with SAH. The authors investigated whether prophylactic administration of AVS could improve cerebral blood flow (CBF) and cerebral glucose utilization (CGU) following SAH in rats.Methods. Anesthetized rats were subjected to intracisternal injection of blood (SAH group) or saline (control group). Either AVS (1 mg/kg/min) or saline (vehicle group) was continuously injected into the rat femoral vein. Forty-eight hours later, positron emission tomography scanning was used with the tracers 15O-H2O and 18F-2-fluoro-d-glucose to analyze quantitatively CBF and CGU, respectively, in the frontoparietal and occipital regions (12 regions of interest/group).In SAH rats receiving only vehicle, CBF decreased significantly (p < 0.05, Tukey's test) and CGU tended to decrease, compared with values obtained in control (non-SAH) rats receiving vehicle. In rats that were subjected to SAH, administration of AVS significantly (p < 0.05, Tukey's test) improved CBF and CGU in both the frontoparietal and occipital regions compared with administration of vehicle alone.Conclusions. Prophylactic administration of AVS improves CBF and CGU in the rat brain subjected to SAH, and can be a good pharmacological treatment for the prevention of DINDs following SAH.


1999 ◽  
Vol 91 (4) ◽  
pp. 605-609 ◽  
Author(s):  
Petra M. Klinge ◽  
Georg Berding ◽  
Thomas Brinker ◽  
Wolfram H. Knapp ◽  
Madjid Samii

Object. In this study the authors use positron emission tomography (PET) to investigate cerebral blood flow (CBF) and cerebrovascular reserve (CVR) in chronic hydrocephalus.Methods. Ten patients whose mean age was 67 ± 10 years (mean ± standard deviation [SD]) were compared with 10 healthy volunteers who were 25 ± 3 years of age. Global CBF and CVR were determined using 15O—H2O and PET prior to shunt placement and 7 days and 7 months thereafter. The CVR was measured using 1 g acetazolamide. Neurological status was assessed based on a score assigned according to the methods of Stein and Langfitt.Seven months after shunt placement, five patients showed clinical improvement (Group A) and five did not (Group B). The average global CBF before shunt deployment was significantly reduced in comparison with the control group (40 ± 8 compared with 61 ± 7 ml/100 ml/minute; mean ± SD, p < 0.01). In Group A the CBF values were significantly lower than in Group B (36 ± 7 compared with 44 ± 8 ml/100 ml/minute; p < 0.05). The CVR before surgery, however, was not significantly different between groups (Group A = 43 ± 21%, Group B = 37 ± 29%). After shunt placement, there was an increase in the CVR in Group A to 52 ± 37% after 7 days and to 68 ± 47% after 7 months (p < 0.05), whereas in Group B the CVR decreased to 14 ± 18% (p < 0.05) after 7 days and returned to the preoperative level (39 ± 6%) 7 months after shunt placement.Conclusions. The preliminary results indicate that a reduced baseline CBF before surgery does not indicate a poor prognosis. Baseline CBF before shunt placement and preoperative CVR are not predictive of clinical outcome. A decrease in the CVR early after shunt placement, however, is related to poor late clinical outcome, whereas early improvement in the CVR after shunt placement indicates a good prognosis.


2005 ◽  
Vol 102 (5) ◽  
pp. 927-929 ◽  
Author(s):  
Michail Plotkin ◽  
Hubertus Hautzel ◽  
Bernd Joachim Krause ◽  
Stephan Mohr ◽  
Karl Josef Langen ◽  
...  

✓ The authors report on a patient suffering from acute Lyme borreliosis who underwent two consecutive [18F]fluorodeoxyglucose—positron emission tomography (FDG-PET) studies demonstrating the course of the disease. The first FDG-PET study revealed markedly increased glucose metabolism in the brainstem, matching exactly the signal abnormalities exhibited on magnetic resonance images and indicating a brainstem tumor. A second PET scan demonstrated no abnormality in this region, thus reflecting clinical remission following antibiotic therapy. Data in the present case indicate that hypermetabolic findings on FDG-PET studies in the brainstem region should be regarded with caution and that neuroborreliosis must be considered as a possible differential diagnosis.


2000 ◽  
Vol 92 (1) ◽  
pp. 64-69 ◽  
Author(s):  
Karen D. Davis ◽  
Ethan Taub ◽  
Frank Duffner ◽  
Andres M. Lozano ◽  
Ronald R. Tasker ◽  
...  

Object. Deep brain stimulation (DBS) of the sensory thalamus has been used to treat chronic, intractable pain. The goal of this study was to investigate the thalamocortical pathways activated during thalamic DBS.Methods. The authors compared positron emission tomography (PET) images obtained before, during, and after DBS in five patients with chronic pain. Two of the five patients reported significant DBS-induced pain relief during PET scanning, and the remaining three patients did not report any analgesic effect of DBS during scanning. The most robust effect associated with DBS was activation of the anterior cingulate cortex (ACC). An anterior ACC activation was sustained throughout the 40 minutes of DBS, whereas a more posteriorly located ACC activation occurred at a delay after onset of DBS, although these activations were not dependent on the degree of pain relief reported during DBS. However, implications specific to the analgesic effect of DBS require further study of a larger, more homogeneous patient population. Additional effects of thalamic DBS were detected in motor-related regions (the globus pallidus, cortical area 4, and the cerebellum) and visual and association cortical areas.Conclusions. The authors demonstrate that the ACC is activated during thalamic DBS in patients with chronic pain.


2002 ◽  
Vol 96 (2) ◽  
pp. 263-268 ◽  
Author(s):  
Arun K. Gupta ◽  
Peter J. Hutchinson ◽  
Tim Fryer ◽  
Pippa G. Al-Rawi ◽  
Dot A. Parry ◽  
...  

Object. The benefits of measuring cerebral oxygenation in patients with brain injury are well accepted; however, jugular bulb oximetry, which is currently the most popular monitoring technique used has several shortcomings. The goal of this study was to validate the use of a new multiparameter sensor that measures brain tissue oxygenation and metabolism (Neurotrend) by comparing it with positron emission tomography (PET) scanning. Methods. A Neurotrend sensor was inserted into the frontal region of the brain in 19 patients admitted to the neurointensive care unit. After a period of stabilization, the patients were transferred to the PET scanner suite where C15O, 15O2, and H215O PET scans were obtained to facilitate calculation of regional cerebral blood volume, O2 metabolism, blood flow, and O2 extraction fraction (OEF). Patients were given hyperventilation therapy to decrease arterial CO2 by approximately 1 kPa (7.5 mm Hg) and the same sequence of PET scans was repeated. For each scanning sequence, end-capillary O2 tension (PvO2) was calculated from the OEF and compared with the reading of brain tissue O2 pressure (PbO2) provided by the sensor. In three patients the sensor was inserted into areas of contusion and these patients were eliminated from the analysis. In the subset of 16 patients in whom the sensor was placed in healthy brain, no correlation was found between the absolute values of PbO2 and PvO2 (r = 0.2, p = 0.29); however a significant correlation was obtained between the change in PbO2 (ΔPbO2) and the change in PvO2 (ΔPvO2) produced by hyperventilation in a 20-mm region of interest around the sensor (ρ = 0.78, p = 0.0035). Conclusions. The lack of correlation between the absolute values of PbO2 and PvO2 indicates that PbO2 cannot be used as a substitute for PvO2. Nevertheless, the positive correlation between ΔPbO2 and ΔPvO2 when the sensor had been inserted into healthy brain suggests that tissue PO2 monitoring may provide a useful tool to assess the effect of therapeutic interventions in brain injury.


1999 ◽  
Vol 90 (3) ◽  
pp. 478-483 ◽  
Author(s):  
Richard G. Bittar ◽  
André Olivier ◽  
Abbas F. Sadikot ◽  
Frederick Andermann ◽  
Roch M. Comeau ◽  
...  

Object. To investigate the utility of [15O]H2O positron emission tomography (PET) activation studies in the presurgical mapping of primary somatosensory cortex, the authors compared the magnitude and location of activation foci obtained using PET scanning with the results of intraoperative cortical stimulation (ICS).Methods. The authors used PET scanning and vibrotactile stimulation (of the face, hand, or foot) to localize the primary somatosensory cortex before surgical resection of mass lesions or epileptogenic foci affecting the central area in 20 patients. With the aid of image-guided surgical systems, the locations of significant activation foci on PET scanning were compared with those of positive ICS performed at craniotomy after the patient had received a local anesthetic agent. In addition, the relationship between the magnitude and statistical significance of blood flow changes and the presence of positive ICS was examined.In 22 (95.6%) of 23 statistically significant (p < 0.05) PET activation foci, spatially concordant sites on ICS were also observed. Intraoperative cortical stimulation was positive in 40% of the PET activation studies that did not result in statistically significant activation. In the patients showing these results, there was a clearly identifiable t-statistic peak that was spatially concordant with the site of positive ICS in the sensorimotor area. All PET activation foci with a t statistic greater than 4.75 were associated with spatially concordant sites of positive ICS. All PET activation foci with a t statistic less than 3.2 were associated with negative ICS.Conclusions. Positron emission tomography is an accurate method for mapping the primary somatosensory cortex before surgery. The need for ICS, which requires local anesthesia, may be eliminated when PET foci with high (> 4.75) or low (< 3.20) t-statistic peaks are elicited by vibrotactile stimulation.


1985 ◽  
Vol 62 (4) ◽  
pp. 539-546 ◽  
Author(s):  
William J. Powers ◽  
Robert L. Grubb ◽  
Roy P. Baker ◽  
Mark A. Mintun ◽  
Marcus E. Raichle

✓ Regional cerebral blood flow (rCBF) and regional cerebral metabolic rate of oxygen (rCMRO2) were measured by positron emission tomography (PET) in four patients with subarachnoid hemorrhage and hemiparesis due to cerebral vasospasm. With resolution of the vasospasm, two patients recovered and two remained hemiparetic. Contralateral to the hemiparesis, rCBF was slightly higher in the two patients who eventually recovered (15.0 and 16.2 ml/100 gm/min) than in the two who remained hemiparetic (12.0 and 11.7 ml/100 gm/min). The rCMRO2 measurements showed similar differences, with values of 1.34 and 2.60 ml/100 gm/min in the patients who recovered, and 0.72 and 1.66 ml/100 gm/min in those who did not. These preliminary findings indicate that with PET studies it may be possible to prospectively differentiate patients with neurological deficits due to reversible ischemia from patients with irreversible infarction.


2000 ◽  
Vol 93 (supplement_3) ◽  
pp. 233-238 ◽  
Author(s):  
Marc Levivier ◽  
David Wikier ◽  
Serge Goldman ◽  
Philippe David ◽  
Thierry Metens ◽  
...  

✓ The purpose of this study was to assess the use of positron emission tomography (PET) as a stereotactic planning modality for gamma knife radiosurgery (GKS). The authors developed and validated a technique for fiducial marker imaging, importation, and handling of PET data for integration into GammaPlan planning software. The clinical feasibility in applying this approach to a selected group of patients presenting with recurrent glial tumors or metastases was evaluated. Positron emission tomography data can be integrated into GammaPlan, allowing a high spatial accuracy, as validated using a phantom. Positron emission tomography data were successfully combined with magnetic resonance (MR) images to define the target volume for the radiosurgical treatment of patients with recurrent glioma or metastasis. This approach may contribute to optimizing target selection for infiltrating or ill-defined brain lesions. Because PET is also useful for the pretreatment and follow-up evaluation, the use of stereotactic PET in these patients can enable an accurate comparison of PET-based metabolic data with MR-based anatomical data. This could give a better understanding of the metabolic changes following radiosurgery. The ability to use PET data in GKS represents a crucial step toward further developments in radiosurgery, as this approach provides additional information that may open new perspectives for the optimization of the treatment of brain tumors.


Sign in / Sign up

Export Citation Format

Share Document